SmartPIN B100 User Manual

 

Operation current: <100mA 

6.5

 

Output Connections 

The RS-232 Output should comply with the standard RS-232 Pin-out as listed below: 

Pin number RS-232 

 

 

6.6

 

Operation LED 

The Op-LED is a surface mount, tri-color, LED, which is visible from the back of the 
SmartPIN B100 housing (using a light pipe). It is molded into the housing. The LED 
provides operating information for the SmartPIN B100. It is a selling feature to the 
integrators for easy maintenance and troubleshooting indications. The following chart gives 
operation status meanings. The blink rate is about 2 times per second with an LED on 
period about 0.25 second. The host should have the option of turning off the indicator. 

 

LED State  

Operating Condition  

Off  

No power  

Steady Green  

Powered on, with keys injected, communication 
established  

Blinking Green  

Powered on, with Keys injected, no communication  

Steady Yellow  

Powered on, no keys, communication established  

Blinking Yellow  

Powered on, no keys, no communication established  

Steady Red  

Powered on & SmartPIN B100 is not functional  

Blinking Red  

Powered on, Tampering detected, keys erased  

Summary of Contents for SmartPIN B100

Page 1: ...80088507 001 A SmartPIN B100 User Manual ...

Page 2: ...e of Contents 1 Scope 3 2 General Description 3 3 Applicable Documents 3 4 Abbreviations 3 5 General Operation 5 6 Specifications 5 6 1 Keys Keypad Layout 5 6 2 Mechanical Dimensions 6 6 3 Operating Environment 7 6 4 Electrical 7 6 5 Output Connections 8 6 6 Operation LED 8 6 7 Reliability 9 6 8 Encryption Key Management 9 ...

Page 3: ... pad is a metal PIN Entry Device with color coded graphics on the Control keys The graphics and raised dot on the 5 key provide key recognition ADA compatibility 3 Applicable Documents IEC 529 for IP environmental rating IEC 950 for Product Safety ADA Americans with Disabilities Act Meets PCI 3 1 requirements and is certified by PCI Meets ANSI X9 8 and X9 24 key management standards Meets ISO 1349...

Page 4: ... for controlling connected SmartPAY terminals IEC International Electrical Congress ISO International Organization for Standardization JPOS Java for Retail Point of Sale LCD Liquid Crystal Display mA MilliAmperes MAC Message Authentication Code MK SK Master Key Secession Key Key management MTBF Mean Time Between Failures mV MilliVolts OPOS OLE for Retail Point of Sale PC Personal Computer or simil...

Page 5: ... for PIN entry so that the PIN pad user does not reveal his PIN during this unsecured operation This option must be in compliance with PCI 3 0 6 Specifications 6 1 Keys Keypad Layout The keypad layout is a 4 by 4 matrix There is a raised dot in number 5 key raise in relief for ADA compliance Keys must be rugged for extended customer operation vandal and tamper resistant The keypad is waterproof an...

Page 6: ...approx Perimeter width 8mm approx Keys are centered in the vertical position Please refer to the figure below for the key layout 6 2 Mechanical Dimensions SmartPIN B100 Envelope dimensions Height 122 mm Width 151 mm Depth 35mm max Keypad dimensions Height 91 mm Width 128 mm ...

Page 7: ...ive Humidity range is 8 to 95 with Wet bulb at 23 73 4 ºF non condensing Dust or continuous sprayed water shall not inter the housing IEC 529 rating IP65 6 4 Electrical Power is supplied to the unit in the following manner RS232C interface A C power adapter 5VDC 10 Optional or Standard internal regulator for 12VDC input USB interface Hub PC supplied power ...

Page 8: ...rs for easy maintenance and troubleshooting indications The following chart gives operation status meanings The blink rate is about 2 times per second with an LED on period about 0 25 second The host should have the option of turning off the indicator LED State Operating Condition Off No power Steady Green Powered on with keys injected communication established Blinking Green Powered on with Keys ...

Page 9: ...Minimum calculated MTBF value of 120 000 power on hours Cable pull force requirement is 5kg straight pull Key Stroke The Key operational life is greater than 2 000 000 key stroke operations any one key 6 8 Encryption Key Management The SmartPIN B100 supports TDES encryption standards for PIN encryption The key management operations supported are Derived Unique Key Per Transaction DUKPT and Master ...