background image

Instructions

Electric Drives

and Controls 

Pneumatics

Service

Linear Motion and 

Assembly Technologies

Hydraulics

Rexroth IndraControl

VAK 10.1, VAK 40.1

Drawer Keyboard

R911338463

Edition 01

Summary of Contents for Rexroth IndraControl VAK 10.1

Page 1: ...Instructions Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics Rexroth IndraControl VAK 10 1 VAK 40 1 Drawer Keyboard R911338463 Edition 01 ...

Page 2: ...e reproduced or given to third parties without its consent Liability The specified data is intended for product description purposes only and shall not be deemed to be a guaranteed characteristic unless expressly stipulated in the contract All rights are reserved with respect to the content of this documentation and the availa bility of the product Published by Bosch Rexroth AG Bgm Dr Nebel Str 2 ...

Page 3: ...ing Signal Words and Safety Alert Symbol 5 4 Intended Use 6 5 Spare Parts Accessories and Wear Parts 6 6 Ambient Conditions 7 7 Technical Data 7 8 Standards 8 8 1 Used Standards 8 8 2 CE Marking 9 8 2 1 Declaration of Conformity 9 8 3 UL CSA Certified 9 9 Interfaces 10 9 1 General Information 10 9 2 Overview 10 DOK SUPPL VAK X0 1 IT01 EN P Rexroth IndraControl VAK 10 1 VAK 40 1 Drawer Keyboard Bos...

Page 4: ...oning 15 12 Device Description 15 12 1 General Information 15 12 2 Operation Displays 16 13 Error Causes and Elimination 16 14 Maintenance 16 15 Ordering Information 17 16 Disposal 17 16 1 Recycling 17 16 2 Packaging materials 17 17 Service and Support 17 Index 19 Bosch Rexroth AG Table of Contents DOK SUPPL VAK X0 1 IT01 EN P Rexroth IndraControl VAK 10 1 VAK 40 1 Drawer Keyboard II 21 ...

Page 5: ...ssembly installation Programmer Mechanic electrician To dismount To dispose Commissioning engineer Technologist Process specialist Maintenance technician Fig 1 1 Assigning the present documentation to the target groups product phases and activities of the target group Purpose This document instructs the technical staff of the machine manufacturer on how to per form the mechanic and electrical inst...

Page 6: ...UT 10 7 5 5 5 1 5 1 5A max I C B T V SW Version V0 002 MNR 1070170021 101 03W19 7261 IND CONT EQ 17YB SN 123456814 15 16 Made in Germany UN AC 230V 115V IN 0 7A 1 4A MNR 1070086255 101 V Nr 1 TYP PCPNL PEN400J1287 IS110 T Bosch Rexroth Electric Drives and Controls GmbH D 64711 Erbach SN 004012652 7261 IND CONT EQ 17YB XXXXXXXXXXXXXXXXX I C B H T V FD 05W01 1 2 3 4 8 9 5 10 6 12 11 13 14 15 16 1 Lo...

Page 7: ...tructions in this documentation contain specific signal words danger warning caution notice and if necessary a safety alert symbol according to ANSI Z535 6 2006 The signal word is meant to draw the reader s attention to the safety instruction and sig nifies the degree of danger The safety alert symbol a triangle with an exclamation point which precedes the sig nal words danger warning and caution ...

Page 8: ...aphic user interfaces To navigate within graphic user interfaces The drawer keyboards may only be operated under the mounting and installation condi tions the position and the ambient conditions temperature degree of protection hu midity EMC etc specified in this documentation Keyboard damage due to unapproved lubricant and cleaner NOTICE Before use check new lubricants or cleaners for compatibili...

Page 9: ...ity 85 Min absolute humidity 1 g m3 Max absolute humidity 25 g m3 Condensation not allowed Corresponds to climatic class 1K2 acc to EN 60721 3 1 Air pressure Up to 3000 m above sea level acc to EN 61131 2 Mechanical strength Max vibration Frequency range 10 up to 150 Hz Excursion 0 075 mm for 10 to 57 Hz Acceleration 1g for 57 to 150 Hz acc to EN 60068 2 6 Max shock 15 g 11 ms acc to EN 60068 2 27...

Page 10: ...vironments EN 60664 1 Overvoltage category II EN 60950 Clearances and creepage distances office environment and power units ISO 13850 Machinery Safety EMERGENCY STOPS EN 60 529 Degrees of protection including housings and installation compartments EN 60 068 2 6 Vibration test EN 60068 2 27 Shock test EN 60721 3 3 Classification of ambient conditions operation EN 60721 3 2 Classification of ambient...

Page 11: ...rial environments IEC 61000 6 2 2005 March 2006 Fig 8 2 Standards for electromagnetic compatibility EMC Non compliance with CE conformity due to modifications to the device The CE marking is only valid for the device in its delivery status After hav ing modified the device the CE conformity is to be verified 8 3 UL CSA Certified The devices are certified according to UL508 Industrial Control Equip...

Page 12: ...ting cable is available at the drawer keyboard Connection type Connector type at the ca ble Connection external USB USB A USB A female connector Fig 9 1 Interface at the drawer keyboard 10 Mounting 10 1 Installation Notes Lay all connecting cables in loops and use strain reliefs for all cables Keep as much distance as possible to noise sources 10 2 Mounting For mounting the drawer keyboard proceed...

Page 13: ...he following pages 2 Remove the paper strip from the seal on the rear side of the front panel 3 Insert the drawer keyboard from the front into the cut out The mounting bolts M4 are inserted into the drilled holes see fig 10 4 Mounting of the device on page 13 4 Fasten the display by screwing the nuts at the rear side of the mounting bolts see fig 10 4 Mounting of the device on page 13 Mechanic dam...

Page 14: ...cut out Fig 10 1 Mounting cut out VAK 10 1 129 387 5 5 5 68 376 58 129 4 5 2 1 Drilled hole for the mounting bolts bore diameter 4 5 mm Mounting cut out Fig 10 2 Mounting cut out VAK 40 1 Bosch Rexroth AG Mounting DOK SUPPL VAK X0 1 IT01 EN P Rexroth IndraControl VAK 10 1 VAK 40 1 Drawer Keyboard 12 21 ...

Page 15: ...least 209 mm 6 or 8 nut M4 Fig 10 3 Mounting of the device 10 3 Housing Dimensions 10 3 1 Front View 88 350 VAK10 1 407 VAK 40 1 IndraControl V Fig 10 4 Front View DOK SUPPL VAK X0 1 IT01 EN P Rexroth IndraControl VAK 10 1 VAK 40 1 Drawer Keyboard Bosch Rexroth AG Mounting 13 21 ...

Page 16: ... 4 43 Fig 10 5 Side view 10 3 3 Top View 316 200 1 Insert bolt for ground connection Fig 10 6 Top View Bosch Rexroth AG Mounting DOK SUPPL VAK X0 1 IT01 EN P Rexroth IndraControl VAK 10 1 VAK 40 1 Drawer Keyboard 14 21 ...

Page 17: ... of the control cabinet PC 11 Commissioning The product can be used directly no configuration is required 12 Device Description 12 1 General Information 1 2 3 4 5 6 7 8 Left mouse button Right mouse button LED for numeric keypad activation LED for Caps Lock activation LED for scrolling Right mouse button Mouse pointer Left mouse button Fig 12 1 Device overview Keyboard The keyboard has all functio...

Page 18: ...wn 14 Maintenance Ensure that the IP degree of protection of the device is kept during mainte nance Keyboard damage due to unapproved lubricant and cleaner NOTICE Before use check new lubricants or cleaners for compatibility with the material of the devices Include the following measures in the maintenance schedule At least once a year all plug and terminal connections of the components are to be ...

Page 19: ...oducts free domicile to the following address Bosch Rexroth AG Electric Drives and Controls Bürgermeister Dr Nebel Straße 2 97816 Lohr am Main Germany 16 2 Packaging materials The packaging materials consist of cardboard plastic material wood or expanded poly styrene EPS The packaging materials can be recycled without any problem For ecological reasons please refrain from returning the empty packa...

Page 20: ...ce worldwide Outside Germany please contact your local service office first For hotline numbers re fer to the sales office addresses on the internet Preparing information To be able to help you more quickly and efficiently please have the following informa tion ready Detailed description of malfunction and circumstances resulting in the malfunction Type plate name of the affected products in parti...

Page 21: ... Maintenance 16 Mounting 10 Mounting cut out 10 O Ordering information 17 P Packaging materials 17 Product identification 4 Purpose 3 R Recycling 17 S Safety alert symbol 5 Safety instructions 5 Scope 4 Scope of delivery 5 Side view 14 Signal words 5 Spare parts 6 Status displays 16 Support See service hotline 17 T Target groups 3 Technical data 7 Used standards 8 Tightening torques 11 Top view 14...

Page 22: ...W Wear parts 6 Bosch Rexroth AG Index DOK SUPPL VAK X0 1 IT01 EN P Rexroth IndraControl VAK 10 1 VAK 40 1 Drawer Keyboard 20 21 ...

Page 23: ...Notes DOK SUPPL VAK X0 1 IT01 EN P Rexroth IndraControl VAK 10 1 VAK 40 1 Drawer Keyboard Bosch Rexroth AG ...

Page 24: ...AK X0 1 IT01 EN P R911338463 Bosch Rexroth AG Electric Drives and Controls P O Box 13 57 97803 Lohr Germany Bgm Dr Nebel Str 2 97816 Lohr Germany Tel 49 9352 18 0 Fax 49 9352 18 8400 www boschrexroth com electrics ...

Reviews: