IDT P9025AC Tuning Manual Download Page 8

P9025AC FOD TUNING GUIDE

8

REVISION  08/26/15

AN-886  

When the Bank# columns are comprised of black and orange numerical values, this means that the error for that 
bank is above target by more than 350mW after the necessary FOD2 Offset shift has been implemented. This 
means that foreign objects are expected to be capable of consuming more power than the WPC specification allows 
at each load level that corresponds to an orange texted cell.  In this case, the spreadsheet predicts the best Bank 
to use regarding all load levels and will indicate the recommended bank by highlighting the suggested FOD1 and 
FOD2 resistances to use under the Bank# row.  The listed values in the FOD1 section are the largest reported power 
error contained within the best fitting Bank and the system designer should determine if the error is acceptable for 
the product under design.

To determine custom values, Bank 8 or Bank 9 can be adjusted using the Hexadecimal values on the PR_Banks 
tab until the selected bank column no longer has red cells. IDT will refer customers to a third party support team for 
programming the P9025AC with a custom FOD configuration.

Figure 4. Power Measurement Connection Diagram

Figure 5. P9025AC_FOD_Calculator.xls Measurements Entry Tab (Second data set not shown but must also 

Summary of Contents for P9025AC

Page 1: ...on the pre programmed FOD curve For WPC compliant systems the loss allowed due to foreign objects is 350 mW not including known losses due to the Tx and Rx systems For systems where WPC compliance is...

Page 2: ...sfer and decode communication packets Respectively the Rx device measures the power that it is receiving i e delivering to the load and reports that value to the Tx module Since the Rx circuit and sys...

Page 3: ...for exact values The Rx Reported Received Power vs Load Current graph is an indication of the power lost due to the electrical operations required for the Tx and Rx to function as the load current cha...

Page 4: ...WER_FOD reported level This offset is applied by connecting an external resistor from pin FOD2 to GND and directly affects the received power level that is reported to the transmitter across the load...

Page 5: ...At 0 9V the offset is 0 mW At 0 V the offset is 300mW and at 1 8V the offset is 300mW The Rx reported received power shift can be calculated using the following equation where VFOD2 is found using equ...

Page 6: ...power value from the Rx Second the FOD1 pin on the P9025AC Rx should be connected to GND This will have the effect of selecting the pre programmed Bank 10 which maxes out the reported power level If...

Page 7: ...left hand input table labeled First data set 7 Move the Rx coil exactly 5mm away from the Optimal Alignment Location in any direction that is 90 Clock wise or counter clockwise from the direction chos...

Page 8: ...the recommended bank by highlighting the suggested FOD1 and FOD2 resistances to use under the Bank row The listed values in the FOD1 section are the largest reported power error contained within the...

Page 9: ...REVISION 08 26 15 9 P9025AC FOD TUNING GUIDE AN 886 be filled in...

Page 10: ...100 MDT BST Reference Testers should be used in conjunction with calibrated lab equipment These laboratories offer excellent Qi compliance FOD determination services and they are recommended Due to th...

Page 11: ...license under intellectual property rights of IDT or any third parties IDT s products are not intended for use in applications involving extreme environmental conditions or in life support systems or...

Reviews: