P9025AC FOD TUNING GUIDE

4

REVISION  08/26/15

AN-886  

Typically, some offsets are included in the reported received power value in order to avoid false FOD disconnects due to coil 
misalignments. These offsets are incorporated by shifting the FOD curve up above the actual power in order to guarantee that 
the Tx power level and the reported power levels are within the 350 mW threshold even when the Rx is off-center by 5 mm from 
the optimal alignment location in any direction accept the z-direction. The bank used to determine the reported power vs. output 
load current is selectable by installing a resistor from pin FOD1 to GND. The following table lists the resistance (±1%) needed 
to select each internal FOD1 bank:

Table 1: FOD1 Bank Selection Table

Power offsets are described in more detail in the next section.

Global Offset (FOD2)

The P9025AC offers an additional layer of flexibility that allows a global power offset to be added to the RX

POWER_FOD

 reported 

level. This offset is applied by connecting an external resistor from pin FOD2 to GND and directly affects the received power 
level that is reported to the transmitter across the load spectrum. The adjustment range allows for ±300 mW shifts to the reported 
power value at all load levels across the spectrum. The magnitude of the FOD2 constant offset adjustment is dependent upon 
the value of the FOD2 resistor and is added to the output power. The valid range for the FOD2 offset resistance is 20k

 up to 

open circuit where 20 k

 results in a +300mW offset and open (FOD2 pin floating) results in -300mW offset.

The following graph indicates the theoretical FOD curve needed to be WPC V1.1.2 Pre-Certified with the P9025AC when using 
the recommended layout and bill-of-materials in the P9025-R-EVK reference kit and shows the reported power shifts that would 
occur at the positive and negative ends of the FOD2 adjustment range.

Figure 2. P9025AC-R-EVK with Wurth FOD Curve (Bank 1), ± FOD2 Global Offset Minimum and Maximum 

Variation Allowance

Bank  #

1

2

3

4

5

6

7

8

9

10

R

FOD1

(k

)

150 to open

113

97.6

75

64.9

56.2

49.9

45.3

40.2

20 to 33.2

Summary of Contents for P9025AC

Page 1: ...on the pre programmed FOD curve For WPC compliant systems the loss allowed due to foreign objects is 350 mW not including known losses due to the Tx and Rx systems For systems where WPC compliance is...

Page 2: ...sfer and decode communication packets Respectively the Rx device measures the power that it is receiving i e delivering to the load and reports that value to the Tx module Since the Rx circuit and sys...

Page 3: ...for exact values The Rx Reported Received Power vs Load Current graph is an indication of the power lost due to the electrical operations required for the Tx and Rx to function as the load current cha...

Page 4: ...WER_FOD reported level This offset is applied by connecting an external resistor from pin FOD2 to GND and directly affects the received power level that is reported to the transmitter across the load...

Page 5: ...At 0 9V the offset is 0 mW At 0 V the offset is 300mW and at 1 8V the offset is 300mW The Rx reported received power shift can be calculated using the following equation where VFOD2 is found using equ...

Page 6: ...power value from the Rx Second the FOD1 pin on the P9025AC Rx should be connected to GND This will have the effect of selecting the pre programmed Bank 10 which maxes out the reported power level If...

Page 7: ...left hand input table labeled First data set 7 Move the Rx coil exactly 5mm away from the Optimal Alignment Location in any direction that is 90 Clock wise or counter clockwise from the direction chos...

Page 8: ...the recommended bank by highlighting the suggested FOD1 and FOD2 resistances to use under the Bank row The listed values in the FOD1 section are the largest reported power error contained within the...

Page 9: ...REVISION 08 26 15 9 P9025AC FOD TUNING GUIDE AN 886 be filled in...

Page 10: ...100 MDT BST Reference Testers should be used in conjunction with calibrated lab equipment These laboratories offer excellent Qi compliance FOD determination services and they are recommended Due to th...

Page 11: ...license under intellectual property rights of IDT or any third parties IDT s products are not intended for use in applications involving extreme environmental conditions or in life support systems or...

Reviews: