IDS X Series User Manual Download Page 31

 

IDS X-series LCD Keypad User Manual   700-411-01C   Issues August 2010 

31 

Quick Reference User Guide 

 

Description 

Programming 

Add a User Code 

[*] [Master Code] [*] [0] [*] [New Code] [*] 

Change a User Code 

[*] [Master Code] [*] [1] [*] [Old Code] [*] [New Code] [*] 

Delete a User Code (Code Known) 

[*] [Master Code] [*] [2] [*] [User Code] [*] 

Add/Edit Slot 

[*] [Master Code] [*] [3] [*] [Slot Number] [*] [User Code] [*] 

Delete a User Code (Slot Known) 

[*] [Master Code] [*] [4] [*] [Slot Number] [*] 

View a Slot Number 

[*] [Master Code] [*] [5] [*] [User Code] [*] 

Edit User Code Properties 

[*] [Master Code] [*] [1] [0] [*] [User Code] [*] [Property 

Number] [*] [*]

 

Allocate a User Code to a Partition 

[*] [Master Code] [*] [1] [1] [*] [User Code] [*] [Partition Number] 

[*] [*] 

User Outputs 

[*] [Master Code] [*] [1] [3] [*] [User Code] [*] [Output Number] 

[*] [Output Action] [*] 

User Reporting Codes Enable 

[*] [Master Code] [*] [1] [4] [*] [User Code] [*] [Bitmap] [*] 

User Reporting Code Telephone 

[*] [Master Code] [*] [1] [5] [*] [User Code] [*] [Bitmap] [*] 

Edit a Zone Name 

[*] [Master Code] [*] [3] [0] [*] [Zone No] [*] [*] [Zone Name] [*] 

Edit the Time                                              

[*] [Master Code] [*] [4] [0] [*] [Time] [*] 

Edit the Date                                              

[*] [Master Code] [*] [4] [1] [*] [Date] [*] 

Change Partitions 

[Mode] [1] [*] [Partition Number] [*] 

Select a Stay Profile 

[Mode] [2] [*] [Profile Number] [*] 

Program/Cancel Stay Zone 

[3] [Zone Number] [*]  

Program/Cancel Buzz Zone 

[4] [Zone Number] [*] 

Program/Cancel Chime Zone 

[2] [Zone Number] [*]  

Quick Arm 

[1] 

Quick Stay 

[5] 

Stay Arm and Go 

[6] 

Bypassing/Un-bypassing a Zone 

[9]  [Master Code] [*] [Zone Number] [*] [*] 

Alarm Memory 

[0]

 

Displays zones violated.

 

View Trouble Conditions 

[7]           1 = AC Mains Fail          2 = No Communication 

                3 = Phone Line              4 = Siren Tamper 

                5 = Low Battery             6 = 12V Aux Fuse 

                7 = Engineer Reset       8 = Box Tamper 

                9 = Tamper on Peripheral Device 

               10 = Comms Loss to Peripheral Device 

               11 = Loss of Power to Peripheral Device 

               12 = EEPROM Failure

 

 

 

 

Summary of Contents for X Series

Page 1: ...IDS X64 LCD Keypad User Manual 700 411 01C Issues August 2010 1...

Page 2: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 2...

Page 3: ...ency Alarms 12 6 1 Fire Alarms 12 6 2 Panic Alarms 12 6 3 Medical Alarms 12 6 4 Duress Alarms 13 7 Alarm Memory 13 7 1 Event Log 13 8 User Codes 14 8 1 Adding Deleting and Editing User Codes 14 8 2 Ho...

Page 4: ...24 9 2 How to Program Cancel Stay Zones 24 10 Buzz Zones 24 10 1 How to Program Cancel Buzz Zones 25 11 Chime Zones 25 11 1 How to Program Cancel Chime Zones 25 12 Viewing Trouble Conditions 26 13 Ch...

Page 5: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 5...

Page 6: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 6...

Page 7: ...partition number Ready to Arm if there are no violated zones otherwise it will display V zone Number zone name for about 3 seconds for each violated zone EXAMPLE If there are no zone violations the ke...

Page 8: ...nly via a designated exit route The panel will away arm at the end of the exit delay if any enter exit zone is violated e g the front door 6 Once the panel has armed the LCD display will read Armed al...

Page 9: ...D Keypad will read Exit Delay the ARM LED will come on and the keypad buzzer will sound for the duration of the exit delay 7 When the panel arms any STAY zones will be automatically bypassed These are...

Page 10: ...display as flashing text Use the PANIC and MED keys to scroll through zones that have been bypassed or violated The keypad buzzer will sound for the duration of the exit delay Only leave via a design...

Page 11: ...tion is registered the strobe will continue flashing after the siren has stopped sounding Entering a valid USER CODE will cancel the strobe 4 2 How to Disarm using a Key Switch or Remote 1 Activate th...

Page 12: ...a smoke detector connected to an appropriately programmed zone The siren will sound on and off repeatedly if programmed and the FIRE REPORTING CODE will be transmitted to the monitoring company To sil...

Page 13: ...d buzzer will sound briefly 3 Use the MED or PANIC keys to scroll through the zones violated during the last armed period 4 Press the 1 key to return to violated zones 5 Press the 2 key to display zon...

Page 14: ...e Table 1 for a summary of programmable options The programmable interface is accessed by entering the USER PROGRAMMING MODE Table 1 User Programming Options Options Summary of Programmable Options Op...

Page 15: ...Option 0 will be displayed on the LCD screen by default Press the key to confirm your entry Once prompted to Enter a User Code input a NEW USER CODE followed by the key Once the user code is programme...

Page 16: ...ns until you reach Menu Option 2 Press the key 4 The LCD display reads User Code 5 Enter the USER CODE to be deleted followed by the key Deleting the code in slot one will reprogram it to 1234 6 Furth...

Page 17: ...play reads User Code 5 Enter the USER CODE followed by the key the slot number is displayed on the keypad 6 Further slot numbers may be viewed by repeating step 5 7 Press the key to exit the User Prog...

Page 18: ...uder It is advisable to choose a code that can be easily remembered by all family or staff members 8 3 7 3 Maid s Code This code can be used to limit access to the premises A maid s code will only dis...

Page 19: ...LCD display reads Option Menu Add User Code 3 To select menu option 11 User Partitions press the 1 1 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options...

Page 20: ...Reserved 09 Zone expander 2 output 2 30 Reserved 10 Zone expander 3 output 1 31 Reserved 11 Zone expander 3 output 2 32 Reserved 12 Zone expander 4 output 1 33 Reserved 13 Zone expander 4 output 2 34...

Page 21: ...5 ON Enable access RC OFF Disable access RC 8 3 11 Option 15 User Reporting Code Telephone Modules MASTER CODE 1 5 USER CODE BITMAP 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The...

Page 22: ...gh the list of programmable options until you reach the option you want 4 Press the key 5 The LCD display reads Zone Names Zone Num 6 Enter the ZONE No followed by the key 7 Press the key to begin ent...

Page 23: ...he User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code 3 To select menu option 41 Edit Date press the 4 1 keys followed by the key or alternatively use...

Page 24: ...s the key to toggle between YES and NO NOTE Buzz zones will be shown by flashing LEDs See Section 10 A Buzz zone cannot be selected as a Stay Zone The Buzz status must be cleared first 7 Repeat steps...

Page 25: ...selected as a Buzz zone 11 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated t...

Page 26: ...ondition has restored To cancel the beeping without viewing the trouble conditions press the key Table 7 Trouble Conditions Zone LED Trouble Condition 1 Panel AC Supply Failure 2 Panel Communications...

Page 27: ...off 1 Hold MODE down for one second until the keypad beeps twice 2 The LCD display reads Mode Number 3 Press the 3 key followed by the key 4 The LCD display reads Output Num 5 Enter the OUTPUT NUMBER...

Page 28: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 28...

Page 29: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 29...

Page 30: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 30...

Page 31: ...Codes Enable Master Code 1 4 User Code Bitmap User Reporting Code Telephone Master Code 1 5 User Code Bitmap Edit a Zone Name Master Code 3 0 Zone No Zone Name Edit the Time Master Code 4 0 Time Edit...

Page 32: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 32...

Reviews: