IDS X Series User Manual Download Page 20

Section: 8 

IDS X-series LCD Keypad User Manual   700-411-01D   Issued August 2010 

20 

5.

 

The LCD display reads „User Code + *‟. 

6.

 

Enter the [USER CODE] followed by the [*] key. 

7.

 

The LCD display reads „Output No. + *‟. 

8.

 

Enter the [OUTPUT No] followed by the [*] key. 

9.

 

The LCD display reads „ *‟. 

10.

 

Enter the [OUTPUT ACTION] followed by the [*] key. 

11.

 

Repeat steps 6 - 10 until all the user outputs have been entered. 

12.

 

Press the [#] key to exit the User Program Mode. 

 

Table 3: Output Address Physical Mapping Data  

 

Address 

Physical Outputs 

 

Address 

Physical Outputs 

00 

Disabled 

 

21 

  Reserved 

01 

Onboard output 1 

 

22 

  Reserved 

02 

Onboard output 2 

 

23 

  Reserved 

03 

Onboard output 3 

 

24 

  Reserved 

04 

Onboard output 4 

 

25 

  Reserved 

05 

Onboard output 5 

 

26 

  Reserved 

06 

Zone expander 1 output 1 

 

27 

  Reserved 

07 

Zone expander 1 output 2 

 

28 

  Reserved 

08 

Zone expander 2 output 1 

 

29 

  Reserved 

09 

Zone expander 2 output 2 

 

30 

  Reserved 

10 

Zone expander 3 output 1 

 

31 

  Reserved 

11 

Zone expander 3 output 2 

 

32 

  Reserved 

12 

Zone expander 4 output 1 

 

33 

  Reserved 

13 

Zone expander 4 output 2 

 

34 

  Keypad 1 output 

14 

Zone expander 5 output 1 

 

35 

  Keypad 2 output 

15 

Zone expander 5 output 2 

 

36 

  Keypad 3 output 

16 

Zone expander 6 output 1 

 

37 

  Keypad 4 output 

17 

Zone expander 6 output 2 

 

38 

  Keypad 5 output 

18 

Reserved 

 

39 

  Keypad 6 output 

19 

Reserved 

 

40 

  Keypad 7 output 

20 

Reserved 

 

41 

  Keypad 8 output 

 

Table 4: Output Actions Data  

 

Value 

Output Action 

00 

Set Output High (Set) 

01 

Set Output Low (Reset) 

02 

Pulse Output High 

03 

Pulse Output Low 

8.3.10

 

Option 14 – User Reporting Codes Enable 

 

[MASTER CODE] [*] [1] [4] [*] [USER CODE] [*] [BITMAP] [*] [#] 

 

1.

 

Enter the User Program Mode as per steps 1 - 4 of section 8.2. 

2.

 

The LCD display reads „Option Menu‟, „Add User Code‟.  

3.

 

To  select  menu  option  14  –  „User  RC  Enable‟,  press  the  [1]  [4]  keys  or  alternatively  use  the 

[PANIC]  or  [MED]  keys  to  scroll  through  the  list  of  programmable  options  until  you  reach  the 

option you want. 

Summary of Contents for X Series

Page 1: ...IDS X64 LCD Keypad User Manual 700 411 01C Issues August 2010 1...

Page 2: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 2...

Page 3: ...ency Alarms 12 6 1 Fire Alarms 12 6 2 Panic Alarms 12 6 3 Medical Alarms 12 6 4 Duress Alarms 13 7 Alarm Memory 13 7 1 Event Log 13 8 User Codes 14 8 1 Adding Deleting and Editing User Codes 14 8 2 Ho...

Page 4: ...24 9 2 How to Program Cancel Stay Zones 24 10 Buzz Zones 24 10 1 How to Program Cancel Buzz Zones 25 11 Chime Zones 25 11 1 How to Program Cancel Chime Zones 25 12 Viewing Trouble Conditions 26 13 Ch...

Page 5: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 5...

Page 6: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 6...

Page 7: ...partition number Ready to Arm if there are no violated zones otherwise it will display V zone Number zone name for about 3 seconds for each violated zone EXAMPLE If there are no zone violations the ke...

Page 8: ...nly via a designated exit route The panel will away arm at the end of the exit delay if any enter exit zone is violated e g the front door 6 Once the panel has armed the LCD display will read Armed al...

Page 9: ...D Keypad will read Exit Delay the ARM LED will come on and the keypad buzzer will sound for the duration of the exit delay 7 When the panel arms any STAY zones will be automatically bypassed These are...

Page 10: ...display as flashing text Use the PANIC and MED keys to scroll through zones that have been bypassed or violated The keypad buzzer will sound for the duration of the exit delay Only leave via a design...

Page 11: ...tion is registered the strobe will continue flashing after the siren has stopped sounding Entering a valid USER CODE will cancel the strobe 4 2 How to Disarm using a Key Switch or Remote 1 Activate th...

Page 12: ...a smoke detector connected to an appropriately programmed zone The siren will sound on and off repeatedly if programmed and the FIRE REPORTING CODE will be transmitted to the monitoring company To sil...

Page 13: ...d buzzer will sound briefly 3 Use the MED or PANIC keys to scroll through the zones violated during the last armed period 4 Press the 1 key to return to violated zones 5 Press the 2 key to display zon...

Page 14: ...e Table 1 for a summary of programmable options The programmable interface is accessed by entering the USER PROGRAMMING MODE Table 1 User Programming Options Options Summary of Programmable Options Op...

Page 15: ...Option 0 will be displayed on the LCD screen by default Press the key to confirm your entry Once prompted to Enter a User Code input a NEW USER CODE followed by the key Once the user code is programme...

Page 16: ...ns until you reach Menu Option 2 Press the key 4 The LCD display reads User Code 5 Enter the USER CODE to be deleted followed by the key Deleting the code in slot one will reprogram it to 1234 6 Furth...

Page 17: ...play reads User Code 5 Enter the USER CODE followed by the key the slot number is displayed on the keypad 6 Further slot numbers may be viewed by repeating step 5 7 Press the key to exit the User Prog...

Page 18: ...uder It is advisable to choose a code that can be easily remembered by all family or staff members 8 3 7 3 Maid s Code This code can be used to limit access to the premises A maid s code will only dis...

Page 19: ...LCD display reads Option Menu Add User Code 3 To select menu option 11 User Partitions press the 1 1 keys or alternatively use the PANIC or MED keys to scroll through the list of programmable options...

Page 20: ...Reserved 09 Zone expander 2 output 2 30 Reserved 10 Zone expander 3 output 1 31 Reserved 11 Zone expander 3 output 2 32 Reserved 12 Zone expander 4 output 1 33 Reserved 13 Zone expander 4 output 2 34...

Page 21: ...5 ON Enable access RC OFF Disable access RC 8 3 11 Option 15 User Reporting Code Telephone Modules MASTER CODE 1 5 USER CODE BITMAP 1 Enter the User Program Mode as per steps 1 4 of section 8 2 2 The...

Page 22: ...gh the list of programmable options until you reach the option you want 4 Press the key 5 The LCD display reads Zone Names Zone Num 6 Enter the ZONE No followed by the key 7 Press the key to begin ent...

Page 23: ...he User Program Mode as per steps 1 4 of section 8 2 2 The LCD display reads Option Menu Add User Code 3 To select menu option 41 Edit Date press the 4 1 keys followed by the key or alternatively use...

Page 24: ...s the key to toggle between YES and NO NOTE Buzz zones will be shown by flashing LEDs See Section 10 A Buzz zone cannot be selected as a Stay Zone The Buzz status must be cleared first 7 Repeat steps...

Page 25: ...selected as a Buzz zone 11 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated t...

Page 26: ...ondition has restored To cancel the beeping without viewing the trouble conditions press the key Table 7 Trouble Conditions Zone LED Trouble Condition 1 Panel AC Supply Failure 2 Panel Communications...

Page 27: ...off 1 Hold MODE down for one second until the keypad beeps twice 2 The LCD display reads Mode Number 3 Press the 3 key followed by the key 4 The LCD display reads Output Num 5 Enter the OUTPUT NUMBER...

Page 28: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 28...

Page 29: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 29...

Page 30: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 30...

Page 31: ...Codes Enable Master Code 1 4 User Code Bitmap User Reporting Code Telephone Master Code 1 5 User Code Bitmap Edit a Zone Name Master Code 3 0 Zone No Zone Name Edit the Time Master Code 4 0 Time Edit...

Page 32: ...IDS X series LCD Keypad User Manual 700 411 01D Issued August 2010 32...

Reviews: