X-SMS 700-485-01B 

Bypass Status 

Desired Action 

Code 

Command  Ext. Comm  Data 

Retrieve bypass status of 
zone 1 

1234 

Bypass 

Status 

Retrieve status of “Lounge” 

1234 

Bypass 

Status 

Lounge 

Check recent activity by retrieving event logs 

The “Event” command is sent by you to retrieve a selectable number of 
events from the Alarm event log. 

Desired Action 

Code 

Command  Ext. Comm  Data 

Retrieving 5 Events 

1234 

Event 

Panel 

NOTE

SMS text is limited by the networks to 160 characters and 

retrieving event logs that exceed 160 characters will amount to a number 
of SMSes being sent

ENHANCE THE FUNCTIONALITY OF YOUR X-SERIES ALARM PANEL 

Using names in reporting and commands 

The X-SMS device itself, and all partitions, zones, and PGM’s can be 
named. These names are used by default in all reports, and can be used 
in commands in place of the default zone / partition / PGM numbers.  

Desired Action 

Code 

Command  Ext. Comm  Data 

Name PGM 5 Lights 

1234 

PGM 

Name 

5:Lights 

Name the X-SMS device 
“Home” 

1234 

Site 

Name 

Home 

Name partition 1 “Main 
House” 

1234 

Partition 

 Name 

1:Main 
House 

Name partition 2 as 
“Granny Flat” & partition 3 
as “Garage” 

1234 

Partition 

Name 

2:Granny 
Flat, 
3:Garage 

Name zone 1 as “Kitchen” 

1234 

Zone 

 Name 

1:Kitchen 

Name zone 2 “Lounge” & 
zone 5 “Patio” 

1234 

Zone 

Name 

2:Lounge, 
5:Patio 

NOTES 

 

The X-Series alarm system does not use site, partition or PGM 
names, names and these cannot be added via the keypad. 

 

If a zone is named via SMS it will over write the zone name on the 
system  

 

If a space is inserted before or after the name then the space 
becomes part of the zone name. 

 

Names are case sensitive 

Update your panel’s time and date via the mobile network 

Desired Action 

Code  Command  Ext. Command  Data 

Set the unit to retrieve the 
time & date from the Cell 
network 

1234  Add 

Time 

Phone Number 

(SIM card number 
inserted in the 
unit) 

NOTE

: Setting the unit to update time will require a SMS to be sent once 

a week to retrieve the time from the cell network. This will be done 
automatically if enabled. 

MANAGE YOUR X-SMS DEVICE REMOTELY 

Lock X-SMS in event of lost phone 

This is the “disabled” mode for use when access to an authorised phone 
number has been lost due to theft or misplacement. To activate the 
lockout send the lockout command from an authorised phone number. 
Once in this mode, the SMS Module will ignore all incoming SMS’s apart 
from a re-enable command from the same number that the disable 
command originated from. There are only two ways to re-enable a 
disabled SMS Module: via the re-enable SMS or by physically pressing 
the reset switch on the module.  

Desired Action 

Code 

Command 

Ext. Comm 

Data 

Temporarily disable the 
SMS module 

1234 

Lockout 

 On 

 

Enable the SMS module 
after being disabled 

1234 

Lockout 

Off 

 

Check and top up SIM airtime balance 

You will use the “Airtime” command to query the current airtime 
balance of the SIM card in the module or to add airtime to the module. It 
is your responsibility to supply the network-dependant strings to 
manage their airtime. 

Desired Action 

Code 

Command 

Ext. Comm 

Data 

Save balance string in the 
SMS module 

1234 

Airtime 

 Command 

Enter the 
string 
supplied  

Query airtime balance 

1234 

Airtime 

Balance 

  

Add airtime 

1234 

Airtime 

 

Network 
supplied 
string 

Add, manage and remove X-SMS users 

Phone Number Categories  

All phone numbers fall into one of three categories, Master, Arming, or 
Reporting, as below.  
Entering phone numbers into the SMS unit is done via SMS’s from a 
“Master Phone Number”. In the default state any cell phone can be used 
to enter the first “Master Phone Number”, once entered the phone with 
that cell number must be used to enter more cell numbers or control the 
system. 

Master Phone Number 

Master phone numbers have the highest level of access to the SMS 
Module. Master phone numbers are allowed access to all configuration 
data. Only master numbers are permitted to add phone numbers to the 
system.  

Arming phone Numbers 

Arming phone numbers are permitted enough access to the module to 
be able to arm and disarm the Alarm Panel and receive reports.  

Reporting Phone Numbers 

Reporting phone numbers are only permitted to receive reports from the 
SMS module, and to temporarily turn off reporting to that number. 

 

How Phone Numbers relate to User Codes 

The SMS module works on the basis of phone numbers, with each phone 
number being a user on the SMS module. The SMS module users’ cell 
numbers are in no way linked to User Codes on the alarm panel. The 
SMS module will only accept commands from known phone numbers 
and will reject commands from unknown numbers or numbers not 
authorised for the command sent.  
Any allowed messages are passed to the panel. The panel elects to 
execute the command based on the following: 

 

Validity of the user code within the alarm 

 

The properties of the user code within the alarm 

 

The current status of the panel 

Therefore, for a person to send a successful command, the following 
conditions must be met: 

 

The phone number must be programmed into the SMS 

 

The user’s cell phone must not be hidden 

 

The phone number must be allocated to a group that allows the 
specified command 

 

The user code must be programmed into the panel 

 

The user code properties must be enabled for the specified 
command 

 

The action must be possible in the current panel status 

 

The command string must be correct and with all the required 
information 

The “Add” command is sent to add a new authorised phone number to 
the SMS Module. You must specify whether the new phone number is a 
Master Phone Number, User Phone Number or a Reporting Phone 
Number.  

Desired Action 

Code 

Command  Ext. Command  Data 

Add phone number as a 
Master number 

1234 

Add 

Master 

Phone Number 

Add phone number as 
an Arm number 

1234 

Add 

Arming 

Phone Number 

Add phone number as a 
Reporting number 

1234 

Add 

Reporting 

Phone Number 

Deleting a phone 
number  

1234 

Delete 

 

Phone Number 

SMS Threshold 

By default the number of SMSes sent per day per phone number is 
limited to 20.  
To increase or decrease the number of SMSes sent to a phone number, 
the “threshold” extended command is sent by the phone number that is 
requesting the change. 

Desired Action 

Code 

Command  Ext. Command  Data 

Increase the reporting 
threshold to 50 SMSes 

1234 

Report 

Threshold 

50 

Decrease the reporting 
threshold to 14 

1234 

Report 

Threshold 

14 

 

Summary of Contents for X Series

Page 1: ... by a valid user code programmed into the alarm panel by your installer FEATURES OF THE IDS X SMS DEVICE Take full remote control of your X Series alarm panel o Arm disarm o Bypass un bypass zones o Home automation via PGM s Keep in touch with your premises o Receive customised reports on panel status and events o Check current panel status o Check recent activity by retrieving event logs Enhance ...

Page 2: ...ass in the data field Zones may be referred to by their number or where applicable by their name Valid command examples Desired Action Code Command Ext Comm Data Bypass zone 1 1234 Bypass 1 Bypass zone 3 4 8 10 1234 Bypass 3 4 8 10 Bypass named zone Passage 1234 Bypass Passage Bypass named zone Lounge Kitchen 1234 Bypass Lounge Kitchen Unbypass Zone 5 1234 Unbypass 5 Unbypass Kitchen 1234 Unbypass...

Page 3: ...zone violations AC Fail Restore and Battery low restore Valid extended commands Type Desired Action Code Command Ext Comm Data Turn on partial reporting 1234 Report Type Partial Turn on global reporting 1234 Report Type Full NOTE Only a Master Phone Number can allocate partitions to a phone number Check current panel status Current arm status zone status and PGM status can be checked Arm Status De...

Page 4: ...Comm Data Name PGM 5 Lights 1234 PGM Name 5 Lights Name the X SMS device Home 1234 Site Name Home Name partition 1 Main House 1234 Partition Name 1 Main House Name partition 2 as Granny Flat partition 3 as Garage 1234 Partition Name 2 Granny Flat 3 Garage Name zone 1 as Kitchen 1234 Zone Name 1 Kitchen Name zone 2 Lounge zone 5 Patio 1234 Zone Name 2 Lounge 5 Patio NOTES The X Series alarm system ...

Page 5: ...airtime Desired Action Code Command Ext Comm Data Save balance string in the SMS module 1234 Airtime Command Enter the string supplied Query airtime balance 1234 Airtime Balance Add airtime 1234 Airtime Network supplied string Add manage and remove X SMS users Phone Number Categories All phone numbers fall into one of three categories Master Arming or Reporting as below Entering phone numbers into...

Page 6: ...the panel The user code properties must be enabled for the specified command The action must be possible in the current panel status The command string must be correct and with all the required information The Add command is sent to add a new authorised phone number to the SMS Module You must specify whether the new phone number is a Master Phone Number User Phone Number or a Reporting Phone Numbe...