IDS MKII Installer Manual Download Page 11

 

IDS Digital Remote Receiver MKII   700-373-02C   Issued April 2010 

11 

Set

 

DIP switches 1 

and

2 for the corresponding relays to pulse or clear switches 1 

and

 2 to toggle. 

Clear

 8 to save settings. 

THE ARMED and READY LED’s flash. 

Clear 

other switches to return to standby. 

The ARMED LED is on. 

 

6.3

 

                                     Assign Panic Relay 

 

 

A panic relay will be triggered by a panic remote - or by holding down any button on a learned remote for 

3 seconds (if this feature is enabled). 

 

Set

 DIP switches 6 then 7.  

The ARMED LED is on, whilst the READY LED flashes. 

Set

 

DIP switch 1 

OR

 2 to select which relay to activate when a Panic Event occurs.  

Clear

 DIP switch 8 to commit panic relay choice to memory. 

The ARMED and READY LED’s will flash. 

Clear

 other switches to return to standby mode. 

The ARMED LED is on. 

 

6.4

 

                                              Assign Relay Button                                             

 

Changing  the  button  that  triggers  a  relay  will  affect  the  remote  used  to  change 

it  as  well  as  any 

remotes that are subsequently learned

The remotes that have already been learned will keep their 

previous  button  to  relay  settings.  (When  pressing  a  button  to  assign  to  a  relay  the  keypad  gives  two 

beeps to indicate the change). 

 

Set

 DIP switch 5, then 8. 

The READY LED is on, whilst the ARMED LED flashes. 

Set

 

either DIP switch 1 or 2 to select the desired relay. 

Press

 the button on the remote that is required to activate the relay. 

 

Any button (on that remote) that was previously programmed to activate that relay will no longer do so.  

 

Repeat

 

for the other relay if so required. 

Clear

 

8 to save this setting.  

The ARMED and READY LED’s will flash. 

Clear

 

other switches to return to standby mode. 

The ARMED LED is on.

 

 

6.5

 

              Relay Secure/Safe Mode 

(Default is Secure for both relays)                             

 

Secure Mode: Loss of supply power will 

not

 

switch the state of the relay – (Normally relaxed). 

 

Safe Mode: Loss of supply power

 

will

 cause the relay to switch state – (Normally activated). When the 

relays are set to Safe Mode, the relay terminal contact N/O and N/C will be switched around. 

 

Set

 

DIP switch 6, then 8. 

The ARMED LED will flash, whilst the READY LED flashes fast. 

Use

 

DIP switches 1 and 2 to select which relays to set for safe mode.  

Clear

 

DIP switch 8. 

Clear

 

DIP switch 6. 

The ARMED and READY LED’s will flash. 

Summary of Contents for MKII

Page 1: ......

Page 2: ...IDS Digital Remote Receiver MKII 700 373 02C Issued April 2010 2...

Page 3: ...ns 7 3 2 Add Remote to Panel 7 3 3 Assigning Alarm Panel Functions to Remote Buttons 8 3 4 Assign Relay to Button 8 3 5 Assign Panic Button 9 3 6 Assign Arm Disarm Button 9 3 7 Assign Stay Arm Button...

Page 4: ...USER CODES stored in the IDS Alarm Panel This means that the Alarm Panel is able to log ARM DISARM events per user Functionality of the receiver is extended with two fully programmable relay outputs w...

Page 5: ...sition of the relevant DIP switches Set On Clear Off During normal operation STANDBY MODE all switches are cleared except the two that are used to select STANDBY MODE options see page 16 Selecting Sta...

Page 6: ...buttons are NOT erased Set DIP switches 1 5 6 7 and lastly 8 Clear 8 to affect the reset Clear all remaining switches to return to standby mode The ARMED LED stays on 2 4 Erase Remotes and Restore Fa...

Page 7: ...he Alarm Panel ADD the user codes that will be assigned to the remote receivers one for each Do this only if the codes have not already been entered before NOTE If you are using a partitioned system p...

Page 8: ...e Alarm Panel s memory Only delete USER CODES if so required existing USER CODES can still be used 3 3 Assigning Alarm Panel Functions to Remote Buttons Remote Assignment Function Dipswitch Learn remo...

Page 9: ...buttons make sure that the relay assignment is the way you require it as per 6 4 Assign Relay Button The new ARM DISARM button will not trigger relay1 If you change the default setting the relay will...

Page 10: ...y IDS remote to add that remote When all the required remotes have been added clear DIP switch 3 These remotes will now operate as per the default settings if these were not altered 6 Operational Mode...

Page 11: ...ep their previous button to relay settings When pressing a button to assign to a relay the keypad gives two beeps to indicate the change Set DIP switch 5 then 8 The READY LED is on whilst the ARMED LE...

Page 12: ...standby mode 7 Fault Finding 7 1 Amber LED Indicator The sole function of this LED is to indicate when there is a valid bus connection between the receiver and an IDS Alarm Panel 7 2 Red and Green LED...

Page 13: ...ming function selected FUNCTION DIP SWITCH SETTING LED STATUS 1 2 3 4 5 6 7 8 RED GRN Learn Relay Pulse Period 0 0 0 0 0 0 1 0 Fast OFF Relay Normal or Fail Safe 0 0 0 0 0 1 0 0 Slow Fast Assign Panic...

Page 14: ...IDS Digital Remote Receiver MKII 700 373 02C Issued April 2010 14...

Page 15: ...IDS Digital Remote Receiver MKII 700 373 02C Issued April 2010 15...

Page 16: ...IDS Digital Remote Receiver MKII 700 373 02C Issued April 2010 16...

Reviews: