Owner’s Manual
700-624-01C
8
Operation of the Keypad
To ensure correct operation of your security system it is essential to familiarize yourself
with the use of the keypad
.
The keypad has a buzzer, command entry keys, zone and system status LED's.
The keypad is used to send commands to the system and to display the current
system status.
The keypad(s) should be mounted in a convenient location within the protected
premises generally close to the Entry/Exit zones.
After a preprogramed period of inactivity, the keypad will automatically enter into
a power-save mode by turning off all the indicators. The keypad "wakes up" or
comes on when any key is pressed or any zones are violated. The power save
feature is programmable and may be disabled.
A sensor which has registered an alarm condition will be indicated on the keypad
by the corresponding zone light flashing.
The keypad buzzer will sound under the following conditions.
o
When any key is pressed during the entry of codes.
o
Three times if one or more of the zones are violated when attempting
to arm the system.
o
To indicate a trouble condition if enabled in programming.
o
During the entry/exit delay.
o
Will sound 5 times when a chime zone is violated.