Quantis Appliance User Manual
Document version : 2.13
Distribution : Confidential
Date : 06.08.2020
Page: 11 / 47
3.1.2
Computer configuration
On your computer connect the USB to Serial cable to an available USB port.
Use a Serial terminal software for instance:
•
On Linux: Putty, Minicom, MobaXterm
•
On Windows: Putty, Teraterm, MobaXterm
Then configure the serial port with the next settings:
•
Serial port baud rate: 115200
•
no parity, 8 data-bits, one stop-bit
Open the connection and press RETURN and the login should be printed:
___ ____ ___ _ _
|_ _| _ \ / _ \ _ _ __ _ _ __ | |_(_) __ _ _ _ ___
| || | | | | | | | | |/ _` | '_ \| __| |/ _` | | | |/ _ \
| || |_| | |_| | |_| | (_| | | | | |_| | (_| | |_| | __/
|___|____/ \__\_\\__,_|\__,_|_| |_|\__|_|\__, |\__,_|\___|
|_|
qa login:
3.1.3
CLI configuration
Then log in with the factory default credentials:
Username:
cliUser
Password:
cliUser
qa login:
cliUser
Password:
Last login: Fri Jul 21 16:48:18 on tty1
=======================================
* *
* ~~ Quantis Appliance CLI ~~ *