3.  GENERAL PART

3.1. 

SCOPE OF USE 

The garage door is designed to close the opening of the building, for cars to drive in and/or for people to enter. Using the garage 

door for other purposes is prohibited.

Read installation and user manuals carefully before using the garage door. The manufacturer is not liable for faults caused by 

improper use and maintenance.

3.2. PROHIBITED

Do not lift objects, animals or persons by door mechanisms.

Do not replace door parts with door parts supplied by other manufacturers.

Acceleration or deceleration of the operation of the door controlled by an automatic drive is not permitted.

3.3. 

ENVIRONMENTAL CONDITIONS

• 

Ensure proper drying or ventilation of the building, otherwise there is a risk of corrosion;

• 

Provide proper protection of the door before starting plastering, painting works since cement, gypsum and other building 

materials can damage the surface of the door; 

• 

Protect the door from aggressive and corrosive substances as this may cause corrosion;

• 

The protective film must be peeled off the door within 30 days of the installation of the door (this instruction does not apply to 

painted door).

•  Optimal climatic conditions for the use of the door:

 

- the outdoor temperature should be ≤ -20°C and ≤ +50°C*. 

 

- relative air humidity from 20% to 90%.

 

- wind speed shall not exceed 30 m/s. 

The  water  resistance  class  is  IP65  (the  door  is  watertight,  there  is  no  leakage  of  liquids  sprayed  on  the  door  surface).  Large 

temperature fluctuations inside and outside the premises can cause surface deflections of the segments (i.e. bimetallic effect may 

occur).  This is especially typical in dark-coloured doors installed on south / southwest side.

Surface must be maintained using the following instruction:

When the ambient temperature is below 0°C, spraying the side sealing rubber with liquid silicone is recommended. Lubricate castor, 

hinge shafts and springs.

Corrosion and aggressive environment may adversely affect the operation of the door.

3.4. CONTROL

Use the door only when there are no obstacles on its path of operation, avoid standing or walking under moving door;

TWO METHODS OF CONTROL ARE POSSIBLE:

MANUAL – 

when the door is lifted by means of a handle, rope or manual chain drive;

AUTOMATIC – 

when the door is opened and closed by an automatic electric drive. The door lock must not be used if the door is 

controlled by means of an automatic drive.

REMOTE CONTROL 

An automatic electric drive can be controlled with help of remote control. The same button on the remote control opens and closes 

the door. Pressing the button once will fully open the door and will stop it. If the button is pressed while the door is rising, the door 

stops. Pressing the button once again closes the door. The drive has an automatic reverse function. It means that if there is an 

obstacle in the path of operation of the door, the door will stop and will automatically rise to the open position. In the event of a 

power failure, the drive may be disconnected and the door may be opened manually.           

 

The automatic drive cover may only be removed by a qualified professional.

Summary of Contents for IDO-HOME

Page 1: ...USER MANUAL DOOR PASSPORT...

Page 2: ...2...

Page 3: ...ons 3 3 Environmental conditions 3 4 Control 3 5 Remote control 4 SAFETY 4 1 Hazards 4 1 Safety 4 1 Precautions 5 EXPLANATION OF SYMBOLS 6 OPERATING TIME AND FAULTS 6 1 1 COMPACT COMPACT models 6 1 2...

Page 4: ...o use the garage door QUALIFIED SPECIALIST A qualified specialist is one who has technical knowledge and experience to work with garage doors This person has to be aware of the potential hazards DOOR...

Page 5: ...ace Large temperature fluctuations inside and outside the premises can cause surface deflections of the segments i e bimetallic effect may occur This is especially typical in dark coloured doors insta...

Page 6: ...nt during the operation contact the company that has installed the door for warranty or post warranty service If protection is triggered by rope rupture or spring breakage immediately contact the comp...

Page 7: ...RBANCES DISTURBANCE POSSIBLE REASON SOLUTION Spontaneous door movement Improperly tightened springs Spring relaxation has occurred after use Contact the door servicing company The door squeaks when op...

Page 8: ...at door model by entering into a contract with a service company approved by the manufacturer The wear of the moving parts and the condition of an automatic drive are inspected The door owner can only...

Page 9: ...T OF INSTALLED COMPONENTS The technical characteristics and performance of the components listed below are described in the relevant installation instructions and or on the identification label of the...

Page 10: ...10 DATE WORKS PERFORMED INSTALLATION COMMISSIONING ADJUSTMENT INSPECTION REPAIR REPLACEMENT OF SAFETY DEVICES TECHNICIAN SIGNATURE CLIENT SIGNATURE...

Page 11: ...AB in a package that ensures safe transportation If the equipment is delivered without packaging Idomus UAB shall not be liable for mechanical damage caused during transportation If after 6 months aft...

Page 12: ...12 B D A A E C C B D A A E C C FRONT SPRINGS BACK SPRINGS...

Page 13: ...13 B D B C C E A A F F G SIDE SPRINGS WICKET DOOR...

Page 14: ...12...

Page 15: ...13...

Page 16: ...UAB IDOMUS V Kr v s av 129 Kaunas Tel 370 37 308 900 info idomus lt www idomus lt...

Reviews: