3. Description
iPump A are compact air-water heat pump with a sc-
roll capsule compressor with inverter technology and
400 V or 230 V power supply.
The Indoor unit of the iPump A includes the conden-
ser, a high e
ffi
ciency loading pump, the switching
valve for heating-/domestic hot water, an immersion
heater, a 200 l DHW storage tank and a sensor set.
The outdoor unit includes the evaporator and the
axial ventilator.
The microprocessor controller NAVIGATOR 2.0 en-
sures e
ffi
cient operation of the heat pump.
The heat pump system is controlled as needed and is
equipped with a variety of monitoring-, security- and
reporting functions.
By default, an unregulated and a regulated heating
circuit can be controlled.
The microprocessor controller NAVIGATOR 2.0 pro-
vides a variety of additional applications, e.g. Smart
Grid, remote control or operation via smartphones.
The heat meter is integrated by default.
A colored 7“ touch display simpli
fi
es the operation of
the heat pump. The display can be removed from the
housing of the iPump A and can be placed separately,
e.g. in the living room.
In order to simplify the transport into the heating
room, the iPump A can be split.
The connections for the refrigerating pipes are optio-
nal on the right or left side of the heat pump.
The connections for heating- and hot water lines are
at the top, as well as the LAN-connection, the cable
inlet for the sensors and the optional connection for
the circulation.
The lower the maximum fl ow temperature
is set, the higher is the effi ciency of the
heat pump.
The electrical lines and refrigerant con-
nection pipes between the indoor and out-
door units are not in the scope of delivery.
The parts are available as accessories
and must be connected according to the
technical specifi cations.
3.1. Intended use
For monovalent heating and cooling of single- and
multiple dwellings with the heat source air. In this
case, the building should be equipped with a low tem-
perature heating systems (e.g. under
fl
oor heating,
wall heating, low temperature radiator heating). The
heat pump may only be used for domestic and not for
purely commercial operation!
The iPump A is working with the safety refrigerant
R410A, that circulates in an closed circuit. When ins-
talled and commissioned properly, meaning that there
is no environmental impact.
3.2. Scope of deliver y
Outdoor unit iPump A
- Housing in sheet metal covering, powder-coated
- Housing optional with cladding panels
- Fin evaporator
- Electronic expansion valve
- Axial ventilator with Flow-Grid
- Mounting kit for the installation of the outdoor unit-
consists of:
4 pcs. threaded bolt M12 x 210 mm
8 pcs. hexagonal nuts M12
8 pcs. washers M12
Indoor unit iPump A
- Heat pump with Scroll-compressor with inverter
technology
- Inverter with patented CIC-Technology
- Copper soldered stainless steel plate heat ex-
changer as condenser
- Refrigerant collector
- Refrigerant dryer
- Refrigerant inspection glass
- Electronic expansion valve
- Electronic high pressure and low-pressure limiter
- Switching valve heating/domestic hot water
- Integrated A-Label loading pump
- Colored 7“ Touch display with NAVIGATOR 2.0
- Stable base frame
- Cladding, insulated against heat and noise
- Sensor package