![iDM iPUMP A 2-7 Installation Instructions Manual Download Page 58](http://html1.mh-extra.com/html/idm/ipump-a-2-7/ipump-a-2-7_installation-instructions-manual_3719130058.webp)
(C) IDM ENERGIESYSTEME GMBH
14. Technical documentation
Installation instructions iPump A 2-7, 3-11
58
Technical documentation
Ka
p
ite
l 1
3
14. Technical documentation
TECHNICAL DOCUMENTATION
according Directive 2010/30/EU and corresponding Regulation (EU) No. 811/2013 (Energy Labelling),
Dircetive 2009/125/EC and corresponding Regulation (EU) No. 813/2013 (Ecodesign)
Rev.0/01-12-2016
Model:
Type of heat pump:
Low-temperature heat pump: (Yes/No)
Temperature application: (35°C/55°C)
Equipped with supplementary heater: (Yes/No)
Heat
pump
combination
heater:
(Yes/No)
Yes
iPump A 2-7
Air-to-water heat pump
Yes
high temperature (55°C)
Yes
Heat
pump
combination
heater:
(Yes/No)
cold
average
warm
cold
average
warm
Rated heat output
P
rated
4,6
4,3
6,5
kW
Seasonal space heating efficiency
Ș
s
129
150
192
%
Climate condition
Climate condition
Dl
d
it
f
t
l
d
Dl
d
it
f
t
l
d
Yes
Outdoor temperature T
j
Outdoor temperature Tj
T
j
= – 15 °C
P
dh
3,7
-
-
kW
T
j
= – 15 °C
COP
d
2,04
-
-
---
T
j
= – 7 °C
P
dh
2,8
4,0
-
kW
T
j
= – 7 °C
COP
d
2,83
2,49
-
---
T
j
= +2 °C
P
dh
1,9
2,3
6,5
kW
T
j
= +2 °C
COP
d
4,10
3,66
2,31
---
T
j
= +7 °C
P
dh
2,4
2,3
4,2
kW
T
j
= +7 °C
COP
d
6,15
2,29
3,98
---
T
j
= +12 °C
P
dh
2,8
2,8
2,7
kW
T
j
= +12 °C
COP
d
9,17
2,82
2,72
---
Declared capacity for part load
(indoor temperature = 20 °C)
Declared capacity for part load
(indoor temperature = 20 °C)
T
j
= Bivalenz temperature (T
biv
)
P
dh
3,7
4,5
6,5
kW
T
j
= Bivalenz temperature (T
biv
)
COP
d
2,04
2,11
2,31
---
T
j
= Operation limit temperature (TOL)
P
dh
3,4
4,5
6,5
kW
T
j
= Operation limit temperature (TOL)
COP
d
1,86
2,11
2,31
---
Bivalenz temperature (Tbiv)
T
biv
-15,0
-10,0
2,0
°C
Operation limit temperature
TOL
-18,0
-10,0
2,0
°C
Cycling interval capacity for heating
P
cych
kW
Cycling interval capacity for heating
COP
cyc
---
Degradation co-efficient
C
dh
0,9
0,9
0,9
---
Heating water operating limit temperature
WTOL
62
62
62
°C
Power consumption in modes other than active mode
Supplementary heater
Thermostat
-off
m
ode
P
TO
00
25
0
025
0
025
kW
Rated
heat
output
(*
)
P
sp
1-
6
1-
6
1-
6
kW
Thermostat
-off
m
ode
P
TO
0,
025
0,
025
0,
025
kW
Rated
heat
output
(
)
P
sup
1-
6
1-
6
1-
6
kW
Standby mode
P
SB
0,022
0,022
0,022
kW
Off-mode
P
OFF
0,022
0,022
0,022
kW
Type of energy input
Crankase heater mode
P
CK
00
0
kW
Other items
For air-to-water heat pumps:
Capacity control
Rated air flow rate, outdoors
---
2.500
m
3
/h
Sound power levels, indoors/outdoors
L
WA
42.3/45.7
42.3/45.7
42.3/45.7
dB
For water- or brine-to-water heat pumps:
electrical
variable
Annual energy consumption
Q
HE
3.407
2.368
1.900
kWh
Rated brine or water flow rate, outdoor heat exchanger
---
n.a.
n.a.
n.a.
m
3
/h
For heat pump combination heater:
Declared load profile
Water heating energy efficiency
Ș
wh
%
Daily electricity consumption
Q
elec
kWh
Daily fuel consumption
Q
fuel
n.a.
n.a.
n.a.
kWh
Annual electricity consumption
AEC
kWh
Annual fuel consumption
AFC
n.a.
n.a.
n.a.
GJ
Contact details:
XL
95,8
8,180
1.749
IDM-Energiesysteme, Seblas 16-18, 9971 Matrei i.O., Austria