VAC-2000UHD / 4000UHD User’s Guide
29
8.2.15 [ F38 ] Copying CEC physical address copy of EDID
CEC: Pass through between IN and OUT1
The CEC physical address of the sink device that is connected to OUT1 can be copied into the EDID of the
VAC.
If the CEC physical address of the connected sink device and the VAC’s address are not the same, the CEC
functions, such as input switching in the sink device at start-up, may not work correctly. The problem can be
solved by using the CEC physical address that is copied into the VAC.
The setting will be applied only if CEC-supported source and sink devices are connected and one of 03 to 46
is selected for “8.2.2 [ F10 ] Setting EDID resolution”.
Setting values
on : Copy physical address
oFF : Not copy physical address [Default]
Note:
CEC system link functions supported by other companies are not guaranteed to work correctly by this setting.
Check the actual configuration.
8.2.16 [ F42 ] Setting EDID WXGA
You can set the number of WXGA pixels
based on the resolution setting of EDID.
The setting will be applied only if one of 03 to 46 is selected for “8.2.2 [ F10 ] Setting EDID resolution”.
Setting values
on : 1366
×
768
oFF : 1360
×
768 [Default]
8.2.17 [ F70 to F7n ] Setting audio output
You can set audio ON/OFF that is output from the HDMI output connectors.
Menu numbers
F70 to F71 : OUT1 to OUT2 (VAC-2000UHD)
F70 to F73 : OUT1 to OUT4 (VAC-4000UHD)
Setting values
on : ON [Default]
oFF : OFF