VAC-2000UHD / 4000UHD User’s Guide
20
8.2.2 [ F10 ] Setting EDID resolution
You can set the EDID to be sent to the source device:
In order to use a built-in EDID (setting values “03” to “28”), set the maximum resolution supported by the sink
device using setting values “03” to “28”.
Setting values
[Table 8.4] The maximum resolution of EDID
Setting
values
Maximum resolution
Pixel
Standard
Remarks
01
EXTERNAL (External EDID)
-
-
If no sink device is connected, the
previous setting will be applied.
02
Copy EDID
-
-
If no collected data, its default is 03.
03
1080p(59.94 / 60)
1920
×
1080
HDTV
Default
04
720p
1280
×
720
05
1080i
1920
×
1080
06
1080p (24 / 25 / 30 / 50)
1920
×
1080
07
SVGA
800
×
600
VESA
08
XGA
1024
×
768
09
VESA720
1280
×
720
For DVI device input
10
WXGA
1280
×
768
11
WXGA
1280
×
800
12
Quad-VGA
1280
×
960
13
SXGA
1280
×
1024
14
WXGA
1360
×
768
、
1366
×
768
The number of pixels can be set in
“
8.2.16 Selecting EDID WXGA”.
15
SXGA+
1400
×
1050
16
WXGA+
1440
×
900
17
WXGA++
1600
×
900
(RB)
18
UXGA
1600
×
1200
19
WSXGA
1680
×
1050
20
VESA1080
1920
×
1080
(RB), For DVI device input
21
WUXGA
1920
×
1200
(RB)
22
QWXGA
2048
×
1152
(RB)
23
WQHD
2560
×
1440
(RB)
24
WQXGA
2560
×
1600
(RB)
(RB)
:
Reduced Blanking