SWC-2000 Command Guide
29
@GTL / @STL
Lighting condition of control command button
Function
Getting
Setting
Format
@GTL, button _1 (,button _2
・・・
)
@STL, button _1, led_1 (,button _2,
led_2
・・・
)
Return value
@GTL, button _1, led_1 (,button _2,
led_2
・・・
)
@STL, button _1, led_1 (,button _2,
led_2
・・・
)
Parameter
button_1-16: Control command button
0 = All control command buttons
1 to 16 = Control command button 1 to Control command button 16
led_1-16: Lighting condition
0 = Lights when a control command is registered [Default]
1 = Lights while a control command is being executed
2 to 9 = Group 1 to Group 8
2 to 9:
- A control command(s) that is linked to a control command button is executed
by pressing the desired button when the control command execution button
lights
Control command button lights regardless of execution
- If any control command is not linked to the control command button, the
button does not light. Another button in the same group keep lighting
Example
@GTL,5
@GTL,5,0
Getting the lighting condition of the
Control command button 5
The control command button lights if a
control command is registered
@STL,2,1
@STL,2,1
Setting the Control command button 2 to
light while a command is being executed
Completed
Remarks
-