5.2.3 Fiber optic cable
To ensure the best performance of a fiber optic cable for a long-haul transmission, select and connect the
proper fiber optic cable correctly.
● Connect a fiber optic cable to the OPF as follows:
Optical output connector of the transmitter & optical input connector of the receiver
Optical input connector of the transmitter & optical output connector of the receiver
● To polish connectors:
For SFP+ module for multi-mode: PC polishing is recommended.
For SFP+ module for single-mode: UPC polishing is recommended.
Note:
APC polishing is not supported.
● Extension distance varies depending on attenuation of the fiber, connector and other contact portions.
● Do not exceed the allowable tension and bend radius; otherwise it may affect the performance of the
product and the product life cycle.
● Make sure to plug the dust cap to the both ends except for when connecting it to the product. Do not leave
a fiber optic cable without the dust cap if you do not use the cable in order to prevent scratches and dirt.
● Before connecting a fiber optic cable to the OPF, make sure there is no scratch or dirt on the ends of the
connector; otherwise, the OPF may not work correctly. Clean it up if it is dirty.
Left: without dust cap
Right: with dust cap
Before cleaning After cleaning
5.2.4 SFP module
The fiber type and extension distance to be used vary depending on the SFP module.
* Some SFP modules for single-mode can extend the transmission distance up to 10 km with OS1.
Please contact us if needed.
Notes:
● Plug the dust cap to the fiber optical cable if you do not use it.
● Do not use the SFP module for other devices. Do not connect the fiber optic cable that is connected to
other devices to the SFP module; otherwise, the SFP module may be broken.
● If you need to replace the SFP module, please contact us.
Multimode fiber
Singlemode fiber
Wave length
850 nm (Oxide VCSEL laser*)
1310 nm (Fabry-Perot laser*)
Maximum extension
distance
OM3: 300 m/984.25 feet
OM4: 1 km/3280.84 feet
OS1: 4.7 km/15419.94 feet
Input level
-11.2 dBm or higher
-13.8 dBm or higher
Output level
-8.2 dBm to -2 dBm
-10.6 dBm to +0.5 dBm
Optical overload
0 dBm
+0.5 dBm
Connector
LC (Duplex)