![Idis TC-S1283WHX Quick Manual Download Page 31](http://html1.mh-extra.com/html/idis/tc-s1283whx/tc-s1283whx_quick-manual_4157992031.webp)
31
• VIEW ANGLE SETUP
VIEW ANGLE SETUP
PANNING RANGE
FLIP : 90
TILT ANGLE LIMIT : 00
SAVE AND EXIT(ESC TO CANCEL)
FLIP
OFF,
AUTO,
90
, 100
, 110
, 120
OFF:
The dome camera moves until 90
vertically.
AUTO:
When the camera reaches the floor directly above the moving object, it will stop.
At that time, release the controller instantly and pull it down again to run the auto-flip function.
When you use the panning range, it is recommended to use the flip mode to AUTO.
90
, 100
, 110
, 120
:
Allows the image to flip digitally when the camera moves over the setting
angle vertically.
TILT ANGLE LIMIT
-10
~ 10
This option is designed to limit the view angle as there is some obstruction in zooming out on
specific areas of the tilt angle.
PANNING RANGE
When the dome camera is installed near a wall, panning range can be limited by user.
PANNING RANGE SETUP
(CTRL KEY)
RIGHT LIMIT : 000.0
LEFT LIMIT : 000.0
ENABLE : OFF
SWAP : OFF
AUTO PAN : ON
SAVE AND EXIT(ESC TO CANCEL)
1. Place the dome camera under 90 degree vertically.
2. Set “
RIGHT LIMIT
” by pressing the
Right
key.
3. Set “
LEFT LIMIT
” by pressing the
Left
key.
4. Set “
ENABLE
” to ON to use.
To exchange the right and the left limit, set “
SWAP
” to ON.
To apply limits on the auto pan (endless panning), set “
AUTO PAN
” to ON.
NOTE: When the flip mode is 90
, 100
, 110
or 120
and you moves over 90
vertically,
the panning range operates in opposite side.