2.4 Setting Dome Camera (DIP Switch)
You can set video type with D1 and termination with D2 in SW1.
SW1-D1
Video Type
SW1-D2
Termination
OFF NTSC
OFF
Not
Terminated
ON
PAL
ON
Terminated
The device which is connected at end of line, whether it is a dome camera or keyboard, must
have the cable for communication terminated by setting the appropriate DIP switch. Without
proper termination, there is potential for control signal errors. Total length of the cable for
communication should not exceed 4000 ft (1.2 km).
You can set coaxitron protocol with D1 and D2 in SW3.
SW3-D1
SW3-D2
HD-TVI OUTPUT
AHD OUTPUT
OFF OFF
Hikvision-C
ACP-PTZ
OFF
ON
Pelco-C Reserved
ON
OFF Reserved
Reserved
ON ON
Reserved Reserved