Battery at 25% power

Battery critically low

Battery empty

Battery charging

Software upgrade is available (SmartService* Solutions customers only)

Warning notification (gray icon indicates the warning has been viewed and is 
unresolved)

Error notification (gray icon indicates the error has been viewed and is unresolved)

Lost communication with IDEXX VetLab Station

Lost Wi-fi communication

Lost Ethernet connection

Powering the Analyzer On/Off

To Power the Analyzer On

Hold the power button until you hear a beep.

To Power the Analyzer Off

Hold the power button for 3 seconds and release when you hear a beep.

Charging the Analyzer

The analyzer will charge automatically when it is plugged into a power source. You can charge the 
analyzer while it is powered on or off, but it will charge faster when the analyzer is powered off. It will 
take approximately 8 hours to charge a completely expired battery when the analyzer is powered off 
during the charging process. 

To Charge the Analyzer

1.  Plug the USB mini B end of the power cord into the power port on the back of the analyzer.
2.  Plug the AC end of the power cord into an appropriate electrical outlet.  

Getting Started

Summary of Contents for SNAP Pro

Page 1: ...SNAP Pro Analyzer Operator s Guide...

Page 2: ...industrial property rights covering this document or subject matter in this document The furnishing of this document does not give a license to these property rights except as expressly provided in a...

Page 3: ...onnected to an IDEXX VetLab Station 8 Confirming Results 9 Viewing Test Results 9 Modifying the Preferences 10 Changing the ProRead Settings 10 Changing the Connection Settings 10 Viewing Past Notific...

Page 4: ...he IDEXX VetLab Station helps you attain a comprehensive picture of your patient s health with the ability to view test results from multiple analyzers on a single report determine disease progression...

Page 5: ...n snap into place 3 Connect the power cord to the analyzer and an appropriate electrical outlet The status light should appear steady yellow Note It will take up to 8 hours to fully charge the analyze...

Page 6: ...analyzer is being used cordlessly or plugged into an electrical outlet corded When the status light appears And is The analyzer Green Solid Has interpreted that all results on the test are negative O...

Page 7: ...power button until you hear a beep To Power the Analyzer Off Hold the power button for 3 seconds and release when you hear a beep Charging the Analyzer The analyzer will charge automatically when it...

Page 8: ...analyzer activates the test and then a countdown timer displays When analysis is complete results are shown on the results screen and are sent to the IDEXX VetLab Station automatically Tip The color...

Page 9: ...lts tap the Check Mark icon The results will then be saved on the analyzer and sent to the IDEXX VetLab Station if applicable Note To cancel the test and return to the Home screen tap the Close icon V...

Page 10: ...etwork and select the IDEXX network OR Tap No if you do not want to connect the analyzer to an IDEXX VetLab Station 3 Tap the Home icon to return to the Home screen Viewing Past Notifications 1 At the...

Page 11: ...ettings and then tap Time 2 If you want to change the time format select a new format underneath the current time display 3 Use the numeric keypad to change the time if necessary 4 Tap the Home icon t...

Page 12: ...il you the updated software for the analyzer For detailed upgrading instructions see the insert included with the upgrade USB drive Cleaning the Internal Components To Be Performed Weekly or As Needed...

Page 13: ...ach solution reflectors lens activator axle 5 Clean the 3 white reflectors the axle and the activator using a new lint free wipe or cotton swab dampened with 70 isopropyl alcohol mild liquid soap and...

Page 14: ...IDEXX Laboratories to obtain replacement batteries This symbol is placed in accordance with the European Union Directive 2002 96 on the Waste Electrical and Electronic Equipment the WEEE Directive If...

Page 15: ...clude many behind the scenes improvements We also recommend rebooting the analyzer weekly If your software is up to date and rebooting did not resolve your issue consult this section for more informat...

Page 16: ...e always upgrade the software when prompted Improper sample preparation An anticoagulant was not used with the whole blood sample The pipette provided with the SNAP test was not used to properly measu...

Page 17: ...use The analyzer base isn t properly locked into place ensure the base is secure and that both fasteners on the base are in the locked position The batteries are in backwards or missing see photo D sh...

Page 18: ...sumption Operating maximum 5 W Batteries Main Batteries Output 3 7 V DC 2 600 mAh Chemistry Lithium ion Type Portable 18650 Rechargeable Yes Weight 50 0 g Button Cell Battery Output 3 V DC 48 mAh Chem...

Page 19: ...n the European Union and is strongly encouraged in all other countries If the equipment is used in a manner other than specified the protection provided by the analyzer may be impaired The SNAP Pro An...

Page 20: ......

Reviews: