background image

dmf2dl5sm-rev0316 

Model DMF2  Page 9  

PILOT VALVE

The pilot valve assembly is accessed by removing the main air distribution 

valve body from the pump and lifting the pilot valve body out of the intermediate 

housing.

Most problems with the pilot valve can be corrected by replacing the 

o-rings. Always grease the spool prior to inserting it into the sleeve. If the

sleeve is removed from the body, reinsertion must be at the chamfered side.

Grease the o-rings to slide the sleeve into the valve body. Securely insert the

retaining ring around the sleeve. When reinserting the pilot valve, push both

plungers (located inside the intermediate bracket) out of the path of the pilot

valve spool ends to avoid damage.

PILOT VALVE ACTUATOR

Bushings for the pilot valve actuators are threaded into the intermediate 

bracket from the outside. The plunger may be removed for inspection or 

replacement. First remove the air distribution valve body and the pilot valve body 

from the pump. The plungers can be located by looking into the intermediate. 

It may be necessary to use a fine piece of wire to pull them out. The bushing 

can be turned out through the inner chamber by removing the outer chamber 

assembly. Replace the bushings if pins have bent.

WARRANTY

This unit is guaranteed for a period of five years against defective material 

and workmanship.

PROBLEM 
 

Pump cycles but will not pump. (Note: higher suction lifts require faster cycling speed for priming.) 

POSSIBLE CAUSES: 

A.

Air leak in suction line.

B.

Excessive suction lift.

C.

Flap valve not seating properly.

D.

Leakage at joint of suction manifold or elbow flange.

E.

Suction line or strainer plugged.

F.

Diaphragm ruptured.

PROBLEM

 

  Pump will not cycle. (Note: Always disconnect air supply to relieve air pressure before disassembling any 

portion of pump.)

POSSIBLE CAUSES: 

A.

Discharge hose or line plugged, or discharge head requirement greater than air supply pressure.

(Disconnect discharge line to check.)

B.

Spool in air distribution valve not shifting. (Remove end cap and check spool — must slide freely.)

C.

Diaphragm ruptured. (Air will escape out discharge line in this case.)

D.

Blockage in diaphragm chamber preventing movement. (Shut off air supply and reopen after

pressure is relieved.) 

PROBLEM

 

Uneven discharge flow. (Indicates one chamber not operating properly.) 

POSSIBLE CAUSES: 

A.

Flap valve not sealing properly in one chamber.

B.

Diaphragm failure in one chamber.

C.

Air leak at suction manifold joint or elbow flange one side.

For additional information, see the Warren Rupp Troubleshooting Guide.

TROUBLESHOOTING - 

For additional information, see the Warren Rupp Troubleshooting Guide.

Tel:  866-777-6060 
Fax: 866-777-6383

Springer Pumps, LLC 

Website: www.springerpumps.com 

Int'l: +001 267 404 2910

Summary of Contents for Warren Rupp DMF2

Page 1: ...lap Valve Servicing 7 Diaphragm Servicing 8 Reassembly 8 Pilot Valve 9 Pilot Valve Actuator 9 Service Instructions Troubleshooting 9 Warranty 9 Material Codes 10 Composite Repair Parts List DMF2S 11 1...

Page 2: ...When the pump is used for materials that tend to settle out or solidify the pump should be flushed after each use to prevent damage In freezing temperatures the pump should be completely drained betw...

Page 3: ...PSI 80 PSI 100 PSI 10 0 20 30 40 50 60 70 80 90 100 20 0 40 60 80 100 120 140 160 10 17 20 34 30 51 40 68 50 85 60 101 9 70 118 9 80 135 9 90 152 9 100 169 9 150 254 9 0 200 300 400 500 600 BAR 100 0...

Page 4: ...TION To order a pump or replacement parts first enter the Model Number DMF2R or DMF2S followed by the Type Designation listed below in the far left column Materials Operating Temperatures For specific...

Page 5: ...119 27 00 686 13 50 343 3 4 NPT AIR INLET SUCTION PORT 2 CAM AND GROOVE DISCHARGE PORT 2 CAM AND GROOVE 3 4 NP 5 58 142 19 80 503 24 50 622 5 58 142 4 69 119 27 00 686 13 50 343 PT AIR INLET SUCTION...

Page 6: ...0 5 58 142 3 4 NPT AIR INLET SUCTION PORT 2 CAM AND GROOVE DISCHARGE PORT 2 CAM AND GROOVE 3 4 NPT AIR EXHAUST 32 00 813 23 85 606 8 73 222 5 58 142 18 50 470 5 58 142 3 4 NPT AIR INLET SUCTION PORT 2...

Page 7: ...an internal pilot valve which alternately pressurizes one side of the air distribution valve spool while exhausting the other side The pilot valve is shifted at each end of the diaphragm stroke by the...

Page 8: ...eezing of the exhaust air causing the pump to cycle erratically or stop operating Thiscanbeaddressedbyusingapointofuseairdryertosupplement a plant s air drying equipment This device will remove excess...

Page 9: ...on the valve body and intermediate reinstall the valve body on the pump using new gaskets Tighten the four hex head capscrews evenly and in an alternating cross pattern AIR EXHAUST If a diaphragm fail...

Page 10: ...outward or toward the head of the center screw Make sure both plates are installed with outer radii against the diaphragm After all components are in position in a vise and hand tight set a torque wr...

Page 11: ...a period of five years against defective material and workmanship PROBLEM Pump cycles but will not pump Note higher suction lifts require faster cycling speed for priming POSSIBLE CAUSES A Air leak i...

Page 12: ...Grade EPDM Color GRAY 370 Butyl Rubber Color Coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile Color Coded RED SI...

Page 13: ...EW HEX HD 7 16 14 X 1 8 15 170 026 330 CAPSCREW HEX HEAD 2 16 170 032 330 CAPSCREW HEX HEAD 8 17 170 035 330 CAPSCREW HEX HD 7 16 14 X 1 50 12 18 170 045 330 CAPSCREW HEX HEAD 4 19 170 052 330 CAPSCRE...

Page 14: ...E 1 4 4 46 620 011 114 PLUNGER ACTUATOR 2 47 670 005 110 RETAINER FLAP VALVE 4 48 675 013 360 RING SEALING 4 49 685 007 120 ROD DIAPHRAGM 1 50 720 004 360 SEAL U CUP 2 51 722 004 110 SEAT FLAP VALVE 4...

Page 15: ...4 7 16 12 27 10 39 1 18 4 5 F 5 C 5 B 5 E 5 D 31 5 A 30 34 56 14 38 46 11 3 50 40 49 57 21 56 17 45 53 35 55 54 13 56 36 2 17 6 32 28 9 2015 Warren Rupp Inc All rights reserved Printed in U S A Model...

Page 16: ...W HEX HEAD 8 14 170 024 330 CAPSCREW HEX HD 7 16 14 X 1 8 15 170 026 330 CAPSCREW HEX HEAD 2 16 170 032 330 CAPSCREW HEX HEAD 8 17 170 035 330 CAPSCREW HEX HD 7 16 14 X 1 50 8 18 170 045 330 CAPSCREW...

Page 17: ...E 1 4 4 46 620 011 114 PLUNGER ACTUATOR 2 47 670 005 110 RETAINER FLAP VALVE 4 48 675 013 360 RING SEALING 4 49 685 007 120 ROD DIAPHRAGM 1 50 720 004 360 SEAL U CUP 2 51 722 004 110 SEAT FLAP VALVE 4...

Page 18: ...F 5 C 5 B 5 E 5 D 31 5 A 30 34 56 14 38 46 11 3 50 40 49 57 21 56 17 45 53 35 55 54 13 19 2 35 55 32 6 28 9 2015 Warren Rupp Inc All rights reserved SANDPIPER is a registered tradename of Warren Rupp...

Page 19: ...nnex VIII This product has used Harmonized Standard EN809 1998 A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc...

Page 20: ...Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX0071 X DEKRA Certification B V 0344 Meande...

Reviews: