Strainers
14
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
Replacement Parts & Troubleshooting
How to Order Replacement Parts
Follow these steps to order replacement parts:
1. Refer to the exploded view drawings on pages 8-15. Find the four-digit item number of
the part that needs replaced. Item numbers are listed on the exploded drawings.
2. In the red Owners Information Packet, you will find a computer printout titled Parts List.
The Parts List lists each item number alongside a five-digit part number. The part number
identifies the specific individual piece, kit, or complete assembly used to assemble that
particular meter.
3. Contact your distributor and give them the five-digit part number. Your distributor will use
it to find the correct part for your strainer.
Troubleshooting
PROBLEM
PROBABLE CAUSES & SOLUTIONS
Meter lockup / the
rotors don't turn
CAUSE A
– Strainer basket rupture possibly due to improper
maintenance of the strainer basket. If this occurred in a new
system, the system may have been improperly flushed.
SOLUTION A
– Replace the strainer basket and follow proper
strainer maintenance procedures. New systems should be
flushed. In all systems, the meter chamber will require cleaning
and may require replacement of parts. Refer to the Installation &
Operation Guide for meter maintenance procedures, or contact
your full service distributor.
CAUSE B
– Debris entered the metering chamber, possibly due
to improper cleaning during strainer maintenance. (Dirt may have
fallen into the strainer housing when the basket was removed for
cleaning.)
SOLUTION B
– Properly clean the strainer housing as outlined in
the Maintenance section in the
topic.
9