Follow these steps to install and operate the strainer:

1.

Flush all new systems

 – Flushing the system

before the meter has been installed is the
preferred first step. Thoroughly flush the lines
until the system is purged of all foreign
materials. See 

Disassembly & Reassembly

for disassembly and reassembly instructions.

2.

Plan a location for the strainer in the system

providing for the following requirements

 –

Ensure there is no pipe strain imposed on the
strainer or any other component part of the
meter assembly. The meter and its accessories
must not support the weight of the piping. Plan
for enough space to allow clearance so that the
strainer basket cover and strainer basket can
be easily removed.

3. Install the strainer:

(a) Install the strainer on the inlet side of the meter
(b) Bolt the strainer outlet to the inlet flanged connection of the meter.
(c) Then bolt the inlet piping to the inlet flanged connection of the strainer.

4. Check the strainer daily during the first 100 hours of operation

 – New or repaired

piping can be the source of welding slag or other foreign material that will block or
rupture the strainer screen–or until no more debris is found in the strainer.

5. Inspect and clean the strainer basket regularly

 – To ensure proper operation.

6. Follow Strainer Maintenance

 – Follow the steps in the Maintenance section below.

Maintenance

It's very important to follow preventive maintenance procedures to protect the strainer as well
as the metering system. Foreign matter such as ice can build up inside the strainer and cause
damage to the strainer and the metering system. When foreign matter builds up inside the

11

Summary of Contents for Liquid Controls F Series

Page 1: ......

Page 2: ...nuals Mobile online version of this manual Get the latest PDF manual Table of Contents Resources in this Guide 3 Publication Updates 4 Safety Procedures 4 Overview 7 Installation Operation 9 Disassemb...

Page 3: ...he introductory and safety information and then proceed to the Installation chapter DISCLAIMER Liquid Controls disclaims all liability for damage to meter or accessories because of corrosion salting o...

Page 4: ...ad and understand the instructions All work must be performed by qualified personnel trained in the proper application installation and maintenance of equipment and or systems in accordance with all a...

Page 5: ...it is used Class I Div 2 For North America installations must be per the U S National Electrical Code NFPA 70 or the Canadian Electrical Code in order to maintain Class I Division 2 ratings This may r...

Page 6: ...appropriate extinguisher for the materials that have caught fire such a Class B fire extinguisher water or fog extinguisher If in doubt call your local fire department IN THE EVENT OF A GAS LEAK IN T...

Page 7: ...squares per inch The outer screen works as a backing It gives reinforcement and support to the fine mesh inner screen Liquid passes through the strainer and into the inlet of the meter Any debris tha...

Page 8: ...the supply tank 2 Close the valve on the vapor return line 3 Close the manual valve in the supply line on the inlet side of the meter If no manual valve exists on the inlet side consult the truck man...

Page 9: ...so that the strainer basket cover and strainer basket can be easily removed 3 Install the strainer a Install the strainer on the inlet side of the meter b Bolt the strainer outlet to the inlet flange...

Page 10: ...ioning properly keep strainer repair costs to a minimum and insure the protection of your metering system Newly installed or repaired systems Check the strainer daily during the first 100 hours of ope...

Page 11: ...r any foreign material Be sure to wipe the housing clean using a soft cloth 4 Clean the strainer basket by flushing the basket with a liquid cleaning agent suited for your application A soft brush may...

Page 12: ...hat occurs after tightening the fasteners indicates a damaged seal or distortion to the surface of the cover In either case the seals or cover must be replaced Additional tightening will not stop the...

Page 13: ...r holes 8 Attach the flat washer 10 and nuts 11 to the screws 9 from below Evenly tighten all nuts and screws See the Torque Chart below WARNING Before refilling or re pressurizing your meter strainer...

Page 14: ...number Your distributor will use it to find the correct part for your strainer Troubleshooting PROBLEM PROBABLE CAUSES SOLUTIONS Meter lockup the rotors don t turn CAUSE A Strainer basket rupture poss...

Page 15: ...ce procedures or contact your full service distributor Meter inspection due to meter inaccuracy reveals scoring of the meter chamber CAUSE See the probable causes for the problem above SOLUTION See th...

Page 16: ...als are allowing product to leak This is caused by a damaged o ring or gasket seal or reusing a PTFE seal after strainer maintenance SOLUTION A Replace the damaged seals Replace PTFE seals if they wer...

Page 17: ...Strainers 17 Get the latest PDF manual https www lcmeter com resources technical manuals Mobile online version of this manual https www lcmeter com manuals Bill of Materials F 7 Aluminum...

Page 18: ...Strainers 18 Get the latest PDF manual https www lcmeter com resources technical manuals Mobile online version of this manual https www lcmeter com manuals F 7 Brass...

Page 19: ...Strainers 19 Get the latest PDF manual https www lcmeter com resources technical manuals Mobile online version of this manual https www lcmeter com manuals F 7 Cast Iron...

Page 20: ...Strainers 20 Get the latest PDF manual https www lcmeter com resources technical manuals Mobile online version of this manual https www lcmeter com manuals F 7 Stainless Steel...

Page 21: ...Strainers 21 Get the latest PDF manual https www lcmeter com resources technical manuals Mobile online version of this manual https www lcmeter com manuals F 15 Aluminum...

Page 22: ...Strainers 22 Get the latest PDF manual https www lcmeter com resources technical manuals Mobile online version of this manual https www lcmeter com manuals F 30 Aluminum...

Page 23: ...Addition of a Magnet and Holder to the FA 7 and FA 15 Strainer Assemblies To help alleviate the problem of premature strainer plugging and to prolong the life of the measuring chamber Liquid Control h...

Page 24: ...Strainers 24 Get the latest PDF manual https www lcmeter com resources technical manuals Mobile online version of this manual https www lcmeter com manuals FS FSAA FSA Configurations...

Page 25: ......

Reviews: