123
M.
Place apparatus in pump gear. SAM enters Auto Mode.
N.
Verify tablet mirrors SAM Control Center display. See Figure 93.
Figure 93. Auto Mode Screen (Tablet/SAM Control Center)
O.
Using tablet, open an intake.
P.
Then open a discharge.
If SAM functions properly, the tablet is ready for use. Place the tablet on the docking station to
charge (leave the tablet powered on until fully charged).
4.11.
Bench Procedures
SAM bench procedures are intended to be performed after the Removal portion of the associ-
ated (referenced or titled) R&R procedure and prior to the Installation portion of the same R&R
procedure. Typically, the bench procedure entails the installation of a repair kit or R&R of the
originally R&R assemblys subcomponents. When the bench procedure is complete, simply click
on the link provided to return to the Installation portion of the original R&R procedure (or use the
table of contents to locate the R&R procedure for the assembly of the same name).
4.11.1
AB Swing-out Valve Motor Rotation
DO NOT USE A DRIVER AND SOCKET TO INITIALLY MOVE A CLOCKED VALVE.
To change the position of the motor on a valve to accommodate an adjacent component or struc-
ture or to provide physical access to the override connection; reference Section III of the Style
8600 Electric Actuator With Motor Driver Installation Instructions (P/N 123248) for a Gen I valve
or Section II and IV of the Style 8600 Electric Actuator Installation Instructions (P/N 127890) for
a Gen II valve.
4.11.2
4-Way Air Valve R&R
THE 4-WAY AIR VALVES ARE CONNECTED TO THE APPARATUS COMPRESSED AIR SUP-
PLY. DO NOT REMOVE A 4-WAY AIR VALVE, PF VALVE AIR CYLINDER, FITTINGS, OR AIR
TUBES WHEN THE SYSTEM IS PRESSURIZED.
Four-way valves are required to route priming suction to each MIV installed on the pump (See
Figure 94). The suction provides air evacuation for the rigid LDH connected to the MIV. The
valves are mounted on the rear of the PVG/MAC valve bracket and require air line (refer to
FSG-PL-00099), plumbing (refer to FSG-PL-01514), and harness connection (see Table 69).
Summary of Contents for Hale Sam
Page 2: ......
Page 37: ...17 Figure 14 SAM Blue CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 38: ...18 Figure 15 SAM Green CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 39: ...19 Figure 16 SAM Red CAN Buss Architecture With Three SAM Control Centers Diagram...
Page 40: ...20 Figure 17 SAM System Drain And Pneumatic Diagram...
Page 41: ...21 Figure 18 SAM Speaks Diagram...
Page 42: ......
Page 58: ...38 THIS PAGE INTENTIONALLY BLANK...
Page 62: ...42 THIS PAGE INTENTIONALLY BLANK...
Page 192: ...172 THIS PAGE INTENTIONALLY BLANK...
Page 206: ...186 THIS PAGE INTENTIONALLY BLANK...
Page 220: ...200 THIS PAGE INTENTIONALLY BLANK...