Design of the relief valve permits the discharge to be piped behind the operator panel for in-
creased operator and/or bystander safety.
2.2.
Installation
The unique design of the Hale Master Intake Valve permits installation in the fire pump suction
tube behind the pump compartment panel using a minimum of space. The valve body is only 3-
3/8 inches (86 mm) wide and various suction tube options are available to fit most standard
pump compartment widths. (Refer to Hale Bulletin 596 for various suction tube options.)
The side mounted valve is installed behind the pump compartment panel between the suction
tube and suction tube extension (Figures 1 and 2). The design of the relief valve mounting flange
permits rotation of the relief valve to redirect the outlet of the relief valve as necessary as well as
remote mounting. There are 2-½ inch female NPT threads machined into the relief valve mount-
ing flange of the MIV valve to permit remote mounting of the relief valve.
Figure 1.
Component Part Identification (Electric Valve)