Idex Godiva GV10000 Installation Manual Download Page 23

 

 

 

 

 

23 

 

©Godiva Ltd. Our policy is one of continuous development. We therefore reserve the right 

to amend specifications without notice or obligation. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Godiva GV10000

Page 1: ...Installation Manual Operation Manual Workshop Manual Parts List Godiva Ltd A Unit of IDEX Corporation Charles St Warwick CV34 5LR England Tel 44 0 1926 623600 Fax 44 0 1926 623666 www godiva co uk go...

Page 2: ...thout notice or obligation AMENDMENT RECORD Model GV10000 Mod No Date Page s Amendment New Issue No July 2002 New Issue 1 1 Sep 2021 39 Insertion of installation manual with corresponding drawings Add...

Page 3: ...N AGAINST FROST 10 PERFORMANCE CURVE 11 PUMP OVERHAUL 12 SUCTION TUBE SUCTION TUBE SEALING RING 12 SUCTION TUBE SEALING RING 12 VOLUTE BODY 13 PRIMING VALVE 13 IMPELLER 14 IMPELLER 14 CARBON SEAL SEAL...

Page 4: ...n pump is running if necessary Maximum allowable inlet pressure is 12 bar Do not run the pump without water for more than one minute Training Godiva pumps must only be operated by trained personnel Ma...

Page 5: ...ction must be carried out if any damage has occurred please contact Godiva Ltd Post production Cleaning Fluid Immediately after production a special cleaning solution is used to clear the pump of any...

Page 6: ...Please contact sales for the drive cable Pump weight 321kg Pump connections Flexible joints are required to be fitted by the vehicle builder to include the drive coupling the suction coupling and the...

Page 7: ...Primer WRP This type requires a header tank 4 5 litres 1 gallon capacity minimum to be installed by the vehicle builder Information sheet ref DS325 page 22 provides details In cold weather a suitable...

Page 8: ...ore reserve the right to amend specifications without notice or obligation LIFTING POINTS Weight Mk21 Gunmetal 321Kg Use lifting straps that can support the respective weights above Mount strap around...

Page 9: ...ossible and can be fresh water or sea water Operator Controls Operation of the pump is by two basic controls discharge valve and pump speed control After use If pump has been used with foam stale wate...

Page 10: ...er out of engagement with the pump drive pulley A non return valve is provided on the water ring primer to prevent air from passing through the primer and into the pump The GVB10000 is made of phospho...

Page 11: ...11 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation PERFORMANCE CURVE...

Page 12: ...y and take off the suction tube This will reveal the suction tube sealing ring which has four holes tapped UNC to allow jacking bolts to be used Joint washers are fitted between the volute body and th...

Page 13: ...and rubber hose from the valve and remove the nuts spring washers plain washers and bolts which secure it to its bracket Lift off the valve To dismantle the valve remove the three nuts spring washers...

Page 14: ...impeller nut and remove the impeller from the splined shaft carefully levering between the impeller and the pump head if necessary When refitting the impeller use a new split pin to secure the slotte...

Page 15: ...off the shaft complete with carbon seal seating ring The seating ring can be removed from the shaft sleeve by removing the round wire circlip which retains it The O ring can then be seen inside the s...

Page 16: ...meter drive remove the two bolts and spring washers securing the tacho drive housing to the bearing housing Take out the drive assembly Normally requires no attention but if a new pinion has to be fit...

Page 17: ...necessary see Chapter 12 The shaft may then be tapped out towards the impeller end with the bearing and the tachometer gear piece Should the bearing remain in the bearing housing it should be tapped o...

Page 18: ...uld be used on the contacting faces To fit a new impeller undo the impeller retaining screw and pull off the impeller note if the impeller binds on the shaft it will be necessary to remove the primer...

Page 19: ...the underside of the disengaging unit and unscrew the disengaging unit from the bracket The primer release pipe may now be removed from the pump body if necessary The disengaging unit is dismantled by...

Page 20: ...it All packages should be signed for on receipt as unexamined In the event of loss or damage a claim should be made on the carrier without delay 3 PARTS CLAIMED TO BE DEFECTIVE AND REPLACEABLE UNDER G...

Page 21: ...of the various assemblies to be ascertained immediately It should be noted that in some cases the parts listed under a particular assembly are not all parts used to make up the assembly concerned This...

Page 22: ...22 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation GVB10000 Spare parts...

Page 23: ...23 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation...

Page 24: ...24 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation...

Page 25: ...25 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation...

Page 26: ...26 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation Pump Head and Pump Drive Shaft...

Page 27: ...27 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation Volute Body and Suction Tube Assembly...

Page 28: ...28 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation Water Ring Primer...

Page 29: ...29 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation Priming Valve...

Page 30: ...30 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation Primer Disengaging Unit...

Page 31: ...31 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation GV10000 Pump Assembly Drawing...

Page 32: ...32 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation...

Page 33: ...o amend specifications without notice or obligation Installation points Pump Mounting Holes with a 20 62mm diameter Use 3 4 UNC or M18 fasteners four off minimum strength grade 8 8 Pump Mounting Holes...

Page 34: ...34 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation...

Page 35: ...35 Godiva Ltd Our policy is one of continuous development We therefore reserve the right to amend specifications without notice or obligation...

Page 36: ...ously lubricated in an oil bath Shaft sealing is by a carbon face seal which being spring loaded is self adjusting and therefore requires no attention The pump discharge flange can be in any of the fo...

Page 37: ...documents scan these QR codes Contact Customer Service Click here for details www godiva co uk customer support Warranty Statement Click here for details www godiva co uk warranty_statement Warranty C...