Page 12
4
、
Adjust the layout of the sound box and the tone arm.
2.6 Alarm input and output connections
1、
Alarm input
A. Alarm input is grounding alarm input.
B. Alarm input demand is the grounding voltage signal.
C. When the alarm is connected with two DVRs or connected with DVR and other equipments, it
should be isolated by relay.
2、
Alarm output
Alarm output can not be connected with high-power load (no more than 1A).When forming the
output loop it must prevent the big current from relay damage. Use the contact isolator when there is a
high-power load
3、
PTZ decoder connections
A. The grounding of the PTZ decoder and DVR must be shared otherwise the common-mode
voltage will lead to the PTZ control failure. The shielded twisted pair is recommended.
B. Avoid the entrance of high voltage. Make the layout reasonably. Take precaution from the
thunder.
C. In the ou
tlying end connect 120Ω resistance paralleled to reduce the inflection and insure the
signal quality.
D. The 485 AB lines of DVR can not connected with other 485 output equipments paralleled.
E. The voltage between the AB lines of the decoder must be less than 5V.
4
、
Front equipment grounding note
Bad grounding can lead to the burnout of the chip.
5
、
Alarm input type unlimited
The DVR alarm output port is constant opening type.
Summary of Contents for ICR-E42-83-163
Page 1: ...Page 1 Identivision ICR E42 83 163 Installer Manual EN ver 1 2...
Page 74: ...Page 74 Weight 3kg without hard disk Installation Desktop...
Page 79: ...Page 79 Appendix 8 FTP Setting 12 14 minutes long videos...
Page 80: ...Page 80 Service LDSZ Kft 1117 Budapest N dorliget u 7 b www identivision hu en...