background image

                                uTrust TS Contact Keypad Reader 

 

 

 

Page 9 of 15 

 

 

 

 
 

6.0  Product Certification ID

’s 

6.1  FCC Certification ID - 

MBPTSKPSC-00 

6.2  IC Certification ID - 

7485A-TSKPSCR0

 

 

7.0  Installation details  

 
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, 
and the authorities having jurisdiction. 

7.1 

  Parts List 

 

 

TS Contact Keypad reader -1 

 

Screws (A #6-18X1.5" SS) - 4Nos 

– Back Plate mounting screws for Wall 

 

Snake Eye Screw (SMF #6-32X5/16

” SS) – 1 No- Top casing mounting security screw 

 

Screws (SMF #6-32x3/8" SS) - 3 N

o’s - 1 casing to back plate mounting screw and 2 Junction 

Box   mounting screws 

 

Nylon anchor plug -4 Nos  

 

6 pin phoenix plug (Phoenix connector version only) 

– 2 Nos 

 

Back Plate 

7.2 

Recommended Infrastructure 

 

 

All cabling and wiring shall be UL Listed and/or UL Recognized 

 

Cable Wiegand      

- 22AWG Shielded cable or better. (Cable P No: ALPHA WIRE, P/N 

1299/10C) 

 

Cable RS485 

  

- 24AWG STP or better 
   shall comply with UL2556 VW-1  

 

Power Supply                 - Class 2 Linear DC PSU - 12 V, 1A min. 

  (for uL compliant installations) 
    ES1 / PS2 Linear DC PSU - 12 V, 1A min. 
  (for IEC 62368 compliant installations) 

 
 
 
 
 
 
 
 
 

Summary of Contents for uTrust TS

Page 1: ...User Manual uTrust TS Contact Keypad Reader 8216 Version 1 1 Confidential Author Sixtus Stanly Version 1 1 Date 11 Aug 2020 Document no 821601_UM...

Page 2: ...Document History Version Date Description of Change Author 1 0 14 Feb 2019 Initial version Sixtus Stanly 1 1 11 Aug 2020 Added ISED French notes Sixtus Stanly...

Page 3: ...rtification ID s 9 6 1 FCC Certification ID MBPTSKPSC 00 9 6 2 IC Certification ID 7485A TSKPSCR0 9 7 0 Installation details 9 7 1 Parts List 9 7 2 Recommended Infrastructure 9 7 3 Connector Informati...

Page 4: ...for third party proprietary protocols The reader supports Wiegand and RS485 OSDP protocol interfaces for communications to the control panel 2 0 Reader 2 1 Functionality 8216 is a physical access cont...

Page 5: ...uTrust TS Contact Keypad Reader Page 5 of 15 2 3 Rear View w o back plate...

Page 6: ...uTrust TS Contact Keypad Reader Page 6 of 15 Reader with Terminal connector Reader with Pigtail cable...

Page 7: ...uTrust TS Contact Keypad Reader Page 7 of 15 Rear View with Backplate Back plate...

Page 8: ...ipment Type of equipment Potted Reader Suitable for Indoor use Interface Type Phoenix connectors and Pigtail cable Voltage Rating 12V DC Current Rating 12V Peak Current 150 mA Average Current 110 mA C...

Page 9: ...MF 6 32X5 16 SS 1 No Top casing mounting security screw Screws SMF 6 32x3 8 SS 3 No s 1 casing to back plate mounting screw and 2 Junction Box mounting screws Nylon anchor plug 4 Nos 6 pin phoenix plu...

Page 10: ...ormation 7 3 1 Pinout diagram Shield Ground Drain Black wire should be connected to the cable shield Caution During Wiring make sure that the VDC lines does not make contact with any other cables as i...

Page 11: ...the wall as per the backplate drawing above b The reader is to be mounted at a height less than 2 meters from the floor for MS1 compliance as per IEC 62368 1 c Insert the nylon screw plugs into the w...

Page 12: ...uTrust TS Contact Keypad Reader Page 12 of 15...

Page 13: ...5 8 0 Power up and Testing 1 Turn power on The LED blinks 3 times green with a long beep then turns red 2 Present a card Contactless card The LED blinks green and a short Beep is heard Contact card Th...

Page 14: ...uTrust TS Contact Keypad Reader Page 14 of 15 3 Press Key Buzzer tone backlight LED blinks...

Page 15: ...following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which...

Reviews: