INSTALLATION GUIDE
TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE.
REVISION DATE: 2020-06-02
Identiv (NASDAQ: INVE) is a global provider of physical security and secure identification. Identiv’s products, software, systems, and
services address the markets for physical and logical access control, video analytics and a wide range of RFID-enabled applications.
For more information, visit identiv.com or email [email protected].
© Identiv, Inc. | All rights reserved. This document is Identiv public information.
Wiring Reference
OPTIONAL DC POWER IN
0v
DC Power Ground
+12
DC Power Input
TB1
Requirements
• 12 – 16 Vdc
• 350 mA
(300 mA external & 50 mA internal)
1
DIGITAL CONTACT INPUTS
R1 - R2
Ground
In1 - In2
Non-supervised or supervised
inputs 1 - 2
4
RELAY OUTPUT
Nc
Normally closed
C
Common
No
Normally open
Relay Contact
DC:
30 Vdc @ 1 Adc
AC:
60 Vac @ 0.5 Aac
5
3
Press and hold this button for 10 seconds to
reset the configuration back to default.
RESET BUTTON
This product is sensitive to Electrostatic Discharges (ESD).
Take precautions while handling the product by using proper grounding straps at all times.
CAUTION
NOTE
As long as the total current of the reader plus a door strike DOES NOT EXCEED 300mA,
you may power the door strike using the power out and ground from the reader Input terminal block.
A flashing green “Ready” LED light on
the Freedom Bridge circuit board indicates
that the bridge is powered but not
connected to a server.
A solid green “Ready” LED light indicates
that the Freedom Bridge has established a
connection to the server and is ready to use.
2
WIEGAND READER INPUT
+12
Power Output
0v
Ground
D1
Data 1 Input
D0
Data 0 Input
Ld
LED Output
Bz
Buzzer Output
Power Output
Using PoE
• 12.0 - 16.5 Vdc
• 300 mA max current
Power Output
Using DC
• 8.5 - 16.0 Vdc
• 300 mA max current