background image

 

iPOINT X – Hardware User Manual | 18.06.2020 

 

Copyright © 2020 IDENTEC SOLUTIONS. All rights reserved. 

8

 

2.  Introduction 

2.1  iPOINT X and System Description 

The iPOINT X device provides a functional ATEX/IECEx certified combination of: The “zone location” system of an 
i-MARK, the long-range Reader functionality of an i-PORT as well as close proximity NFC functionality, encased in 
an attractive, rugged, IP67 housing. 
 

 

 
 
The Housing contains: 

5 Status LEDs (see Section 3.1) 

a Connection Chamber where the wired interfaces can be accessed 

Relevant cable glands, as wired access points, depending on the device setup 

Mounting Plate and securing screw (see Section 4) 

 
For a detailed description of how to correctly open the connection chamber and other mechanical information, 
please refer to Section 4.1. 
 
The iPOINT X can used as a standalone device or with an interface to an access controller. See Section 2.3 for 
more details. 
 
Following is a description of the wireless technologies that are available within the iPOINT X Device. 
 
 

 

Summary of Contents for iPOINT X

Page 1: ...IDENTEC SOLUTIONS Model IDS1002 iPOINT X ATEX HARDWARE USER MANUAL...

Page 2: ...person for any special incidental indirect or consequential damages including without limitation damages resulting from use of or reliance on information presented herein or loss of profits or revenu...

Page 3: ...ended This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Conformit l exposition aux champs RF des quipements radio Pour satisfaire aux exigences...

Page 4: ...National Electrical Code WARNING Not to be connected to equipment that uses or generates more than 250V with respect to earth ground WARNING This product contains components that are sensitive to ele...

Page 5: ...ocuments The iPOINT X was designed tested and supplied in perfect condition according to document EN 62368 1 2014 and EN60950 22 Safety Requirements Condensate Change of Temperature To avoid condensat...

Page 6: ...15 2 3 2 RS485 MASTER Connectors Pinout 15 2 3 3 RS422 HOST Connectors Pinout 15 2 3 4 RS485 HOST Connectors Pinout 15 2 3 5 Connector coding 16 2 4 Cabling Hints 16 2 5 Lid Open Detection 16 3 Initi...

Page 7: ...o the content contained herein It is the user s responsibility to contact the service department for any possible changes or updates to operating and maintenance procedures Updates will be provided up...

Page 8: ...g The Housing contains 5 Status LEDs see Section 3 1 a Connection Chamber where the wired interfaces can be accessed Relevant cable glands as wired access points depending on the device setup Mounting...

Page 9: ...ocols The iPOINT X has two internal UHF antennas built in and can communicate up to a range of 500 meters with its Tags The main benefit of two antennas is the elimination of RF dead spots in static s...

Page 10: ...LF power Minimum Delay between LF telegram Minimum Cycle delay Description 0 to 39 0 ms 10 ms All slots active 40 to 59 40 ms 10 ms Only 6 slots per frame are active 1 slot inactive between 2 actives...

Page 11: ...reserved 11 2 1 2 NFC Interface The NFC Interface is a Near Field Communication interface The iPOINT X can be used as an entry terminal or for other NFC communication The range to the Tag is around 10...

Page 12: ...Tracking and Tracing Localization Environmental Data Sensing i B350 Tags IDENTEC SOLUTIONS i B350 tags are designed to be cost effective and easy to implement while offering maximum flexibility The b...

Page 13: ...ew Topologies RS422 MASTER RS422 or RS485 cable connector to the host computer for connector details see section 2 3 1 RS422 HOST This can be used as a communication interface to an access controller...

Page 14: ...All rights reserved 14 Installation RS422 with Access control Installation RS485 with access control RS422 RS485 and Power supplies must go through Barrier VCL1520X outside of the Hazardous Area Pleas...

Page 15: ...e Barrier 15V DC 1 3 GND Ground Supply from the barrier 4 GND Ground Supply from the barrier 5 DATA RS485 Data communication from the barrier 6 DATA pin 6 bridged to pin 5 7 DATA RS485 Data communicat...

Page 16: ...please see Ex entity data The following table assumes that 2 wires of the cable are used for power supply connection For the Lapp lflex EB CY 7 x 0 75 1 50 the shield shall also be used for GND conne...

Page 17: ...ks Orange when a response or a broadcast is received LF This is the LF Communication LED LED blinks green when Marker Loop ID is sent It blinks red if LF is not working properly e g loop broken or loo...

Page 18: ...s from the front side until magnetic connection is released lift off 2 Loosen the 8x screws be aware DO NOT pull out the screws out completely the gasket can be damaged 3 Lift off the lid 4 Now you ha...

Page 19: ...ting plate only 4x countersunk screws are required with a maximum diameter of 5mm or M5 screws Length and type shall be chosen depending on wall material 4x countersunk screws Choose screw type and le...

Page 20: ...there s a risk of damage 4 2 1 Optional Extra Pole Mount Bracket Kit A Pole Mount Bracket Kit is available Pole Mount Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to...

Page 21: ...Extension Bracket Kit is available Extension Bracket Kit o Contains the bracket and accessories o The bracket can be mounted to a wall with M8 Bolts or via threaded rods e g wall anchors o Multiple mo...

Page 22: ...iPOINT X Hardware User Manual 18 06 2020 Copyright 2020 IDENTEC SOLUTIONS All rights reserved 22...

Page 23: ...e included in the host system How this could look in detail depends on the relevant system concept and very likely varies from one system to another A Brief Checklist Are all housings intact Are all c...

Page 24: ...mmended that these parameters are set before the component is entered into the spare part stock system In most cases all units within an identification system are used in the same way so that only one...

Page 25: ...UHF LF COM RUN NFC Electrical Power Source 15 VDC 1 over Barrier VCL1520X Environmental Conditions Operating Temperature 40 C to 70 C 40 F to 158 F Storage Temperature 40 C to 85 C 40 F to 185 F Humi...

Page 26: ...tennas internal Group P1 Pin Value P1 Pin Value Frequency Value Ui V Ii A Pi W IIB IIC P1 1 P1 2 16 065 0 474 1 904 P1 5 P1 7 P1 6 P1 8 6 135 0 196 0 301 UHF 868 MHz 920 MHz 10 0 Uo V Io A Po W IIB II...

Page 27: ......

Reviews: