2.3.1 RS422 MASTER Connectors & Pinout
Wago
: 713-1404
Pin Number Designator Comment
1
V+
Supply Voltage from the Barrier:
+15V DC (+/-1%)
2
V+
Supply Voltage from the Barrier:
+15V DC (+/-1%)
3
GND
Ground Supply from the barrier
4
GND
Ground Supply from the barrier
5
RX-
RS422 communication from the barrier
6
TX-
RS422 communication from the barrier
7
RX+
RS422 communication from the barrier
8
TX+
RS422 communication from the barrier
2.3.2 RS485 MASTER Connectors & Pinout
Wago
: 713-1404
Pin Number Designator Comment
1
V+
Supply Voltage from the Barrier:
+15V DC (+/-1%)
2
V+
Supply Voltage from the Barrier:
+15V DC (+/-1%)
3
GND
Ground Supply from the barrier
4
GND
Ground Supply from the barrier
5
DATA-
RS485 Data communication from the barrier
6
DATA-
*pin 6 bridged to pin 5*
7
DATA+
RS485 Data communication from the barrier
8
DATA+
*pin 8 bridged to pin 7*
2.3.3 RS422 HOST Connectors & Pinout
Wago
: 713-1404
Pin Number Designator Comment
1
-
Not Connected
2
-
Not Connected
3
-
Not Connected
4
-
Not Connected
5
RX-
RS422 communication from the barrier
6
TX-
RS422 communication from the barrier
7
RX+
RS422 communication from the barrier
8
TX+
RS422 communication from the barrier
2.3.4 RS485 HOST Connectors & Pinout
Wago
: 713-1404
Pin Number Designator Comment
1
-
Not Connected
2
-
Not Connected
3
-
Not Connected
4
-
Not Connected
5
DATA-
RS485 Data communication from the barrier
6
DATA-
*pin 6 bridged to pin 5*
7
DATA+
RS485 Data communication from the barrier
8
DATA+
*pin 8 bridged to pin 7*