background image

 

 

6.  Technical Specifications 

Communication ILR

350 

technology

 

Operation Mode 

 

 

 

UHF Broadcast or response communication  

Read Range 

 

 

 

up to 500 m 

1

 

Compatibility 

 

 

 

i-PORT M352, i-MARK S350, iPOINT, i-PORT BT USB 

Operating Frequency 

 

 

 

UHF ISM Band: 868 MHz (EU) or 920 MHz (NA)

2

 

Antenna / Transmit Power 

 

 

 

1x Internal Antennas / <1mW 

 

 

 

 

 

Communication LF

boost

 Marker

 

Operation Mode 

 

 

 

Receives Marker ID at a predefined interval, transmits over UHF 

Exciter Range 

 

 

 

up to 5m

 

(adjustable)  

1

 

Compatibility 

 

 

 

i-MARK S350, iPOINT 

Operating Frequency 

 

 

 

125kHz 

 

 

 

 

 

Communication NFC

 

 

 

 

 

Antenna 

 

 

 

Integrated 13.56MHz coil (read/write) 

Standards 

 

 

 

ISO/IEC 15693, ISO/IEC 14443A&B, Sony FeliCa 

Usage 

 

 

 

Programmable functionality 

 

 

 

 

 

Electrical 

 

 

 

 

Battery 

 

 

 

CR2477 Coin Cell (non-replacable) 

Battery Lifetime expectancy 

 

 

 

Up to 10 years (depending on use case) 
e.g. up to 7 years with 2 sec. ping rate & 8 hrs/day working   

 

 

 

 

 

Environmental Conditions 

 

 

 

 

Operating Temperature 

 

 

 

-40°C to +70°C (-40°F to +158 °F) 

Storage Temperature 

 

 

 

-40°C to +85°C (-40°F to +185°F) 

Humidity 

 

 

 

Up to 100% 

Shock: 

 

 

 

EN 60068-2-32: Multiple drops to concrete from 1m (3ft), 5 times 
EN 60068-2-29: 50G on all 3 axis, 3 times per axis 

Vibrations 

 

 

 

EN 60068-2-64: noise 5 to 1000Hz, 90 minutes per axis 
EN 60068-2-6: 5G, 20 sin wave cycles per axis, 5-500Hz 

Standard/Certification 

 

 

 

 

Europe 

 

 

 

CE

 (EN 300 220-1, -2, -3; EN 301 489-1,-3; EN 62368-1) 

North America 

 

 

 

FCC

 Part 15 (US); 

IC

 RSS210 

 
Mechanical Data 

 

 

 

 

Push Button 

 

 

 

Event Generation 

Status Display 

 

 

 

Bi-Color LED 

Dimensions 

 

 

 

(L) 90 x (W) 41 x (T) 12 mm 

Housing Colours 

 

 

 

Front/back:

 RAL 9002 Light Grey, 

Button:

 RAL 7024 Graphite Grey 

Enclosure Material 

 

 

 

Plastic (PC-ASA) 

Enclosure Rating 

 

 

 

IP67 

Weight 

 

 

 

40g

 

 

 

 

 

 

Order Code

 

 

 

 

 

iQ355 P   

 

 

 

456000 

ID Cardholder (ATEX) 

 

 

 

456051 

Safe-Strap Basic Black 3 mm ATEX w/o knob 

 

 

 

711828 

1

 The communication range depends on environmental conditions and national regulation limits 

2

 Other country frequencies are available, please contact IDENTEC SOLUTIONS 

 
 
 
 

 

Summary of Contents for IDS1000

Page 1: ...IDENTEC SOLUTIONS Model IDS1000 iQ355 P Personnel Tag HARDWARE USER MANUAL...

Page 2: ...or consequential damages including without limitation damages resulting from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if in...

Page 3: ...ith part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including int...

Page 4: ...to electrostatic discharges Please observe the special instructions for their protection Incorrect handling can damage the unit and cause the invalidation of the warranty Minimum safety precautions ag...

Page 5: ...accidental use and the service unit responsible immediately informed Safety Documents The iQ355 P was designed tested and supplied in perfect condition according to document IEC EN 60950 1 Safety Req...

Page 6: ...NFC Interface 10 2 2 System Components Readers 11 2 3 Tag Functions 12 2 3 1 Pushbutton 12 2 3 2 LED Indicators 12 2 3 3 Configuration 12 3 Mechanical Information Installation 13 3 1 Mounting Options...

Page 7: ...t the service department for any possible changes or updates to operating and maintenance procedures Updates will be provided upon request The information in this document may be subjected to changes...

Page 8: ...ower microcontroller and a non replaceable high capacity coin cell battery Pushbutton for alarm generation battery status or general debugging Configurable Bi color LED for Alarm indication battery st...

Page 9: ...he iQ355 P has an internal UHF antenna and can communicate up to a range of 500 meters with a reader or iPOINT device 2 1 2 LF Interface The LF Interface uses IDENTEC s LFBOOST Marker technology Zone...

Page 10: ...ce is a Near Field Communication interface The iPOINT can be used as an entry terminal Alternatively the tag can communicate with access control system over standard NFC interfaces The range from the...

Page 11: ...of up to 500 m 1640 ft Identec s i PORT BT USB readers can be installed at fixed locations or used as a mobile reader to provide seamless communication with the iQ355 P tags The mobile reader can the...

Page 12: ...Long hold 5 seconds T B D 2 3 2 LED Indicators LED Indication Information Additional Information Blinking Green T B D Solid green T B D Blinking Red T B D Solid Red T B D Blinking Orange T B D Solid...

Page 13: ...tion Housing Dimensions 3 1 Mounting Options The tag can be mounted in the following ways Carried in a pocket used with a keyring used with a neck strap All ways of wearing the tag can also be done wi...

Page 14: ...ll cables intact Are all connectors intact Are all connectors securely fastened Are all screws still tight Is there a sudden malfunction at a specific unit What are the status of the LEDs is the RUN L...

Page 15: ...power units on which the customer can carry out only very limited repairs Normally the repairs are carried out at IDENTEC SOLUTIONS or possibly at a distributor Before a part is sent in for repair a...

Page 16: ...day working Environmental Conditions Operating Temperature 40 C to 70 C 40 F to 158 F Storage Temperature 40 C to 85 C 40 F to 185 F Humidity Up to 100 Shock EN 60068 2 32 Multiple drops to concrete...

Page 17: ......

Reviews: