6

 

Technical Data 

Operating Data Long-Range RFID (ILR, Beacon Technology) 

Read range 

Up to 30 m (90 ft) in free air 

Operating frequency 

868 MHz (EU) or 915 MHz (NA) ISM band 

Operation mode 

Transmits a pre-programmed data string 
in regular intervals 

Repetition rate (ping rate) 

0,5 – 60 seconds, adjustable in steps of 0,5 seconds 

Transmit power 

< 1 mW 

Compatibility 

i-PORT 4B, i-PORT MB, i-CARD CF B 

 

Electrical Data 

Power supply 

Lithium battery (not replaceable) 

Battery lifetime expectancy 

4 years @ 2 seconds ping rate 

 

Configuration 

The transponder is configured using the i-PROG MB at a distance of max. 5 cm. 
Ping rate 

Configurable from 0.5 to 60 seconds  
in steps of 0.5 seconds 

User data 

9 Bytes (user definable) 

 

Environmental Conditions 

Operating temperature 

–30 to +70 °C (–22 to +158 °F) 

Shock 

50 G, 3 times acc. DIN IEC 68-2-27 
several times onto concrete floor from 1 m height 

Vibration 

3 G, 20 sine wave cycles, 5 to 150 Hz,  
DIN IEC 68-2-6 

 

5 G, noise 5 to 1.000 Hz, 30 minutes 
DIN IEC 68-2-64 

 

Mechanical Data 

Dimensions 

43 × 38.5 × 14.5 mm (1.7 × 1.5 × 0.57 inches) 

Casing Plastics 
Mass 40 

Protection class 

IP 65 

 

Certifications 

EMC 

CE (EN 300 220-1, -3; ETSI EN 301 489-1, -3), 
FCC Part 15 (US), Industry Canada 

ATEX/IECEx certificates 

II 1 G Ex ia IIC T4, Certificate Number: DNV-2008-OSL-ATEX-42107 

 
 
 
 
 

Summary of Contents for i-B2X W

Page 1: ...i B2X W Wristband Tag Manual...

Page 2: ...n damages resulting from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility of such damages...

Page 3: ...5 2 3 SCOPE OF THIS DOCUMENT 5 2 4 SAFETY INSTRUCTIONS 5 2 5 RESPONSIBILITY 5 2 6 ASSOCIATED DOCUMENTS 5 2 7 SCOPE OF DELIVERY VISUAL INSPECTION 6 2 8 OPTICAL IDENTIFICATION OF THE TAG 6 3 INITIAL OPE...

Page 4: ...of 11 1 Radio Frequency Compliance Statement FCC Compliance Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authorit...

Page 5: ...n this document are suitable for ATEX conformity 2 4 Safety Instructions Operational Safety The device described in this manual is for exclusive operation by trained employees The correct and safe use...

Page 6: ...d service organization of IDENTEC SOLUTIONS should also be informed to facilitate the repair or exchange of the system 2 8 Optical Identification of the Tag The label is on the rear side of the tag pr...

Page 7: ...o not open the housing Configuration is done using the built in air interface of the i B2X W Configuration The i B2X W is configured using the i PROG MB programming device Things to be configured The...

Page 8: ...ed as every standard wristwatch The band should not be too loose This avoids that the tag slides down over the wrist and prevents possible injury For maximum convenience put the end of the wristband u...

Page 9: ...le connections could lead to damage and malfunctions of the system and therefore should be repaired as soon as possible A Brief Checklist Are all housings intact Are all cables intact Are all connecto...

Page 10: ...tion The transponder is configured using the i PROG MB at a distance of max 5 cm Ping rate Configurable from 0 5 to 60 seconds in steps of 0 5 seconds User data 9 Bytes user definable Environmental Co...

Page 11: ...i B2X W Page 11 of 11 Dimensional Drawing...

Reviews: