background image

 

MSO Fingerprint scanners Installation Guide 
Revision History 

 

 

 

 

 

2018_2000039830 
October 2021 

This document and the information therein are the property of IDEMIA. They must not be copied 
or communicated to a third party without the prior  authorization of IDEMIA 

 

Revision History 

 

Revision 

Date 

Document revision history 

1.0 

November 2002 

Creation of the document 

1.1 

November 2002 

Add chapter “MSO100 Material Compatibility” 

1.2 

December 2002 

Add chapter “Finger positioning” 

1.3 

January 2003 

Clarifications 

1.4 

July 2003 

Add chapter “MSO300” 

1.5 

October 2003 

Precisions with the LEDS states 

1.6 

March 2004 

MSO 300 S getting started 

1.7 

June 2004 

Add information about Smart Card option 
Add MSO3xx suspend mode LEDs status 

1.8 

July 2004 

Add MMI description for MSO350 
Add IDENTLITE license reference 

1.9 

December 2004 

Precisions with the LEDS states 
Add MSO CBM 

2.0 

April 2005 

Update of hotline phone number 

2.1 

July 2005 

Added the MSO xx1 products reference 

2.2 

September 2005 

Add the "SAGEM MorphoSmart™ Service Provider Usb Server" 
installation in the USB driver installation for MSO3xx and CBM. 

2.3 

January 2006 

Added installation procedure for Windows XP ® embedded. 

2.4 

June 2006 

Minor form modifications 
Corrected performance description 

2.5 

December 2006 

FCC recommendations 

2.6 

August 2007 

Updated company name 
Removed MSO100 items. 

2.7 

December 2007 

Added the MSO1350 model 

2.8 

May 2008 

New plan. 
Upgrade biometric performances description. 

2.9 

March 2009 

Add IP (Ingress Protection) rating (se

IP Rating

) 

Change hotline address 

Add information about USB driver installation (se

Note for 

administrators

) 

2.10 

September 2009 

Update hotline mail address 

Summary of Contents for MSO1300

Page 1: ...MSO Fingerprint scanners Installation Guide October 20212 2018_2000039830 Version 2 24 MSO300 MSO301 MSO1300 MSO1350 MSO Fingerprint scanners Installation Guide ...

Page 2: ...ny purpose without the express written permission of IDEMIA The software described in this document is supplied under a license agreement or nondisclosure agreement It is against the law to copy the software on any medium except as specifically allowed in the agreement This manual makes reference to names and products that are trademarks of their respective owners PROPRIETARY RIGHTS This document ...

Page 3: ...July 2004 Add MMI description for MSO350 Add IDENTLITE license reference 1 9 December 2004 Precisions with the LEDS states Add MSO CBM 2 0 April 2005 Update of hotline phone number 2 1 July 2005 Added the MSO xx1 products reference 2 2 September 2005 Add the SAGEM MorphoSmart Service Provider Usb Server installation in the USB driver installation for MSO3xx and CBM 2 3 January 2006 Added installat...

Page 4: ... 15 March 2013 Update registered office address 2 16 October 2013 Update MSO1300 and MSO1350 pictures from 2014 2 17 May 2015 Update footer legal text 2 18 Feb 2018 Update Company s logo 2 19 November 2018 Update registered office address and company s name Update power supply information 2 20 June 2019 Change MorphoSmart by MSO Update 3 with MSO USB driver Update 13 with MSO KMS Update 2 4 2 with...

Page 5: ...4 1 1 Dimensions and Weight 15 4 1 2 Temperature range and humidity 15 4 1 3 IP rating 15 4 2 General description 16 4 2 1 Top view 16 4 2 2 Bottom view 16 4 3 MSO301 devices specificities 17 4 4 Specific Cleaning Precautions 17 4 5 Specific recommendations 17 5 MSO1300 18 5 1 Physical Characteristics 18 5 1 1 Dimensions and Weight 18 5 1 2 Temperature range and humidity 18 5 1 3 IP rating 18 5 2 ...

Page 6: ...ine Interface 28 8 2 1 Description 28 8 2 2 Biometric terminal status 28 8 2 3 Biometric request status 28 8 2 4 Smart card reader status MSO1350 28 9 Secure MSO getting started 29 9 1 Description 29 9 2 Installation 29 9 3 Reference 29 10 Recommendations 30 10 1 Warning 30 10 2 Cable bend radius 30 10 3 Areas containing combustibles 30 10 4 Repair 30 10 5 Usage 31 10 6 Accessories 31 10 7 Environ...

Page 7: ...orization of IDEMIA 7 List of figures Figure 1 MSO300 3D View 15 Figure 2 MSO3xx Top View 16 Figure 3 MSO3xx Bottom View 16 Figure 4 MSO1300 18 Figure 5 MSO1300 3D view 19 Figure 6 MSO1300 Bottom view 19 Figure 7 MSO1350 20 Figure 8 MSO1350 top view and side view 22 Figure 9 MSO1350 bottom view 22 Figure 10 MSO S unlocking with KMS application 29 Figure 11 MSO cable radius recommendation 30 Figure...

Page 8: ...4 MSO 300 devices IP rating 16 Table 5 MSO 1300 devices weight and sizes 18 Table 6 MSO 1300 devices temperature and humidity range 18 Table 7 MSO 1300 devices IP rating 19 Table 8 MSO 1350 devices weight and sizes 20 Table 9 MSO 1350 devices temperature and humidity range 21 Table 10 MSO 1350 devices IP rating 21 Table 11 Database size 25 Table 12 Not encrypted Database fulfill time 25 Table 13 I...

Page 9: ...g more than 20 years of experience in the field of biometric identification and the processing of literally millions of individual fingerprint identification records We believe you will find the MSO terminal fast accurate and easy to use as a biometric peripheral The MSO terminal offers the following advantages High quality optical scanner Software development suite MSO SDK for all MSO devices Key...

Page 10: ...only The MSO terminals must be placed on a flat clear surface where it will not be at risk of coming in contact with fluids 2 2 MSO Hardware Platform Compatibility The MSO USB devices are compatible with usual PC configurations but we therefore strongly advise you to perform a compatibility test with target PC hardware configuration The MSO USB devices are compatible with most of the self powered ...

Page 11: ...the USB connector of the MSO USB device to a USB port of the PC Wait for USB enumeration process usually not more than a few seconds Then the device is ready for use for example with the sample applications delivered with MSO SDK please refer to MSO SDK section 2 3 3 MSO SDK The MSO Software Development Kit provides the required elements to enable you to develop your own applications for MSO devic...

Page 12: ...e tab to apply Titre 1 to the text that you want to appear here 2018_2000039830 October 2021 This document and the information therein are the property of IDEMIA They must not be copied or communicated to a third party without the prior authorization of IDEMIA 12 ...

Page 13: ... processed as a Communication Device Class CDC in accordance with the USB Device Class Specifications version 2 0 available from the www usb org web site in developers documents section The MSO devices comply with the USB 1 1 standard They operate in Full Speed mode 12 Mbit s with USB 1 1 USB 2 0 USB 3 0 and USB 3 1 hosts or hubs The MSO communication protocol over USB is described in the R2 and R...

Page 14: ...tion therein are the property of IDEMIA They must not be copied or communicated to a third party without the prior authorization of IDEMIA 14 3 MSO USB driver installation 3 1 MSO USB driver setup Get The MSO USB Driver installation package and double click on setup exe to install it After installation the plugged MSO device will be listed on ports Com LPT category in Device Manager ...

Page 15: ...e MSO3xx 3xx1 are dedicated to be connected to an USB port which supplies the required power Figure 1 MSO300 3D View 4 1 1 Dimensions and Weight Device Dimensions L x w x h Weight Sensor MSO3xx 80 x 92 x 57 mm 300 g 416 x 416 pixels Table 2 MSO 300 devices weight and sizes The weight doesn t include the cord 4 1 2 Temperature range and humidity Device Temperature range Humidity Operating Storage O...

Page 16: ...on of IDEMIA 16 MSO30x which integrates a MSO xxx OEM IP53 rated sensing window Table 4 MSO 300 devices IP rating The table above defines also the maximum value of the IP ingress protection rating which can be reached by a product which integrate according to the appropriate recommendations an OEM model 4 2 General description 4 2 1 Top view Figure 2 MSO3xx Top View 4 2 2 Bottom view Figure 3 MSO3...

Page 17: ...ust with their fingers Use compressed gas for electronic devices to avoid electrostatic discharges In order to eliminate organic marks a weekly cleaning is required In this case using a rag moistened with diluted dishwashing liquid is advised It is advised to clean the sensor after 1000 uses with a lightly damp rag to dry it and to wait a few minutes before starting up again the terminal The clean...

Page 18: ...ics The MSO1300 device is dedicated to be connected to an USB port which supplies the required power Figure 4 MSO1300 5 1 1 Dimensions and Weight Device Dimensions L x w x h Weight Sensor MSO1300 68 7 x 39 7 x 15 3 mm 40 g 400 x 256 pixels Table 5 MSO 1300 devices weight and sizes The weight doesn t include the cord 5 1 2 Temperature range and humidity Device Temperature range Humidity Operating S...

Page 19: ...the prior authorization of IDEMIA 19 MSO1300 which integrates a CBM OEM IP65 rated sensing window Table 7 MSO 1300 devices IP rating The table above defines also the maximum value of the IP ingress protection rating which can be reached by a product which integrate according to the appropriate recommendations an OEM model 5 2 General description 5 2 1 3D view Figure 5 MSO1300 3D view 5 2 2 Bottom ...

Page 20: ...r communicated to a third party without the prior authorization of IDEMIA 20 6 MSO1350 6 1 Physical Characteristics The MSO1350 includes a smart card reader and is dedicated to be connected to an USB port which supplies the required power Figure 7 MSO1350 6 1 1 Dimensions and Weight Device Dimensions L x w x h Weight Sensor MSO1350 82 x 71 x 41 mm 140 g 400 x 256 pixels Table 8 MSO 1350 devices we...

Page 21: ...1 2 Temperature range and humidity Device Temperature range Humidity Operating Storage Operating Storage MSO1350 0 C to 50 C 20 C to 70 C 10 RH 85 RH 95 Table 9 MSO 1350 devices temperature and humidity range 6 1 3 IP rating Device IP rating MSO1350 which integrates a CBM OEM IP65 rated sensing window Table 10 MSO 1350 devices IP rating The table above defines also the maximum value of the IP ingr...

Page 22: ...information therein are the property of IDEMIA They must not be copied or communicated to a third party without the prior authorization of IDEMIA 22 6 2 General description 6 2 1 Top view and Side view Figure 8 MSO1350 top view and side view 6 2 2 Bottom view Figure 9 MSO1350 bottom view USB connector Smart Card Slot Sensor Plastic casing USB cable Product sticker Rubber feet ...

Page 23: ...MIA 23 6 2 3 Smart Card Reader characteristics MSO1350 device is equipped with a smartcard reader that complies with ISO 7816 1 2 3 PC SC protocol CCID over USB2 protocol CPU based cards with T 0 and or T 1 protocol ISO 7816 Class A B and C smartcards 5V 3V and 1 8V Card Reader characteristics ID1 Cards EMV Level 1 Insertion Cycles at least 100 000 Smart Detections Smart Card detection Movement de...

Page 24: ...r authorization of IDEMIA 24 7 MSO device Technical Characteristics 7 1 Electrical characteristics 7 1 1 USB connection All USB MSO devices The MSO devices comply with the USB 1 1 standard They operate in Full Speed mode 12 Mbit s with USB 1 1 USB 2 0 USB 3 0 and USB 3 1 hosts or hubs 7 1 2 Power Supply For all MSO devices DC Power supply 5 Volts 5 as shown on the product label 5V Standby mode 500...

Page 25: ... records when redundant template check is off Number of records 500 3000 5000 USB 17s 100s 172s Table 12 Not encrypted Database fulfill time 7 2 3 Verify performances The verify process compare the search fingerprint to one or more reference fingerprints less than 1 second typical time Please not that The measure starts with finger valid placement on the sensor and stops with result returned to th...

Page 26: ...a finger which is recorded as the 1st fingerprint of the user s record It also means that the time required to reject a fingerprint No Hit is higher than the time required to match with the 1st fingerprint of a record Number of records Hit fingerprint 1 Hit fingerprint 2 No Hit 100 1 s 1 5 s 1 5 s 500 1 1 s 1 5 s 1 5 s 2000 1 5 s 2 s 2 s 3000 2 s 2 5 s 2 5 s 5000 2 5 s 3 s 3 s Table 13 Identify pe...

Page 27: ...tus The tables below describe the meaning of the light signals 8 1 2 Biometric terminal status Status Sensor Lower LED Upper LED Suspend low power mode Off Off Off Stand By wait for a request Off Flashing Green See Maintenance State such as firmware update in progress Off Blinking Red Blinking Red Personalization State secure MSO Off Blinking Red Blinking Red Unrecoverable Error or USB enumeration...

Page 28: ...inal status Status Sensor Suspend low power mode Off Stand By wait for a request from host system Off Maintenance State such as firmware update in progress Blinking Personalization State secure MSO Blinking Unrecoverable Error or USB enumeration Error Off Table 16 MSO13x0 system status 8 2 3 Biometric request status Status Sensor Waiting For Finger On Waiting For Finger Removal On Finger Misplaced...

Page 29: ...cation Install MKMS by double clicking on MKMS installer version exe After installation start the MKMS application in C IDEMIA MSO Key Management System Select the Root key generation action in the Initialization menu to create your MSO Certification Authority Click Insert Transport Files button to import the two transport files and their passwords into the MKMS database figure 1 Set up the value ...

Page 30: ...ncorrectly 10 2 Cable bend radius When the cable need to be bended please to figure below it is recommended to have a bend radius value higher than 1 2 cm Figure 11 MSO cable radius recommendation 10 3 Areas containing combustibles It is strongly recommended that you do not install your MSO terminal in the vicinity of gas stations petroleum processing facilities or any other facility containing fl...

Page 31: ...ischarge and depending on the environment synthetic carpet should be avoided in areas where the MSO terminal has been installed 10 8 Cleaning precautions It is recommended to clean the sensor when it is dirty It is recommended to use a blowgun before rag in case users brought sand or hard dust with their fingers Use compressed gas for electronic devices to avoid electrostatic discharges In order t...

Page 32: ...d the information therein are the property of IDEMIA They must not be copied or communicated to a third party without the prior authorization of IDEMIA 32 Any other practices Scratch materials bleach chlorine soda alcohol quaternary ammonium acid products permanently damage and or negatively impact the performances of the device They can irreversibly damage the product ...

Page 33: ...are certified for many countries including Morocco For declarations of conformity and details please see https www biometric terminals com 11 2 MSO1300 MSO 1300 products are traced through Model Number MPH SE 005A MPH SE 005B There are certified for many countries including Morocco For declarations of conformity and details please see https www biometric terminals com 11 3 MSO1350 MSO 1300 product...

Page 34: ...pied or communicated to a third party without the prior authorization of IDEMIA 34 12 Bibliography Title Description EDM reference R1 MSO Overview General information about MSO product family 2018_2000039827 R2 MSO Host System Interface specifications chm ILV Protocol Description of commands N A R3 MSO SDK Programming guide chm MSO SDK guide for programmers N A R4 NEMO FW Reference Manual chm CBM ...

Page 35: ...nformation available on website https biometricdevices idemia com s USA Canada Email support bioterminals us idemia com Phone 1 888 940 7477 LATAM Latin America Email support bioterminals us idemia com Phone 1 714 575 2973 EMEA Europe Middle East Africa Email support bioterminals idemia com Phone 33 1 30 20 30 40 APAC Asia Pacific Email support bioterminals in idemia com Phone 91 8929 159 665 Indi...

Page 36: ...ased when the finger is optimally positioned Common non optimal finger positioning is illustrated below followed by an illustration of best finger placement Fingerprint Placement Fingerprint Orientation Fingerprint Inclination Fingerprint Rotation Figure 12 Finger placement recommendations Other recommendations for acquiring a quality finger image Fingers should neither be too moist nor extremely ...

Page 37: ...e tab to apply Titre 1 to the text that you want to appear here 2018_2000039830 October 2021 This document and the information therein are the property of IDEMIA They must not be copied or communicated to a third party without the prior authorization of IDEMIA 2 ...

Page 38: ...Copyright 2020 IDEMIA Registered Office 2 place Samuel de Champlain 92400 Courbevoie France www idemia com ...

Reviews: