MorphoWave Compact - 2018_2000035853-v81
4.3 > Output Relay
14
Yellow / White
RLY_NO
Contact relay (normally open)
12
Grey / White
RLY_COM
Contact relay common
13
Orange / White
RLY_NC
Contact relay (normally closed)
Figure 22: Output relay wiring
Nominal characteristics of relay
Load characteristics:
1 A max @ 30 VDC (according to the safety extra low voltage requirements independently of the power
supply),
Resistive load or inductive load; see warning information hereafter for inductive load,
The internal relay is designed for at least 100 000 cycles (resistive load).
Inductive load management requires a parallel diode for a better contact lifetime.
Example of connection for electrical door locks
MorphoWave SP
terminal
Figure 23: Example of electric latch connection
Summary of Contents for MorphoWave SP
Page 1: ...Copyright 2021 Idemia November 2021 2018_2000035853 v81 MorphoWave SP Installation guide ...
Page 2: ...Copyright 2021 Idemia November 2021 2018_2000035853 v81 ...
Page 7: ...7 MorphoWave Compact 2018_2000035853 v81 1 Introduction ...
Page 19: ...19 MorphoWave Compact 2018_2000035853 v81 2 General description ...
Page 27: ...27 MorphoWave Compact 2018_2000035853 v81 3 Installation procedure ...
Page 40: ...40 MorphoWave Compact 2018_2000035853 v81 4 Electrical interface ...
Page 57: ...57 MorphoWave Compact 2018_2000035853 v81 5 User interface ...
Page 61: ...61 MorphoWave Compact 2018_2000035853 v81 6 Recommendations ...
Page 65: ...65 MorphoWave Compact 2018_2000035853 v81 7 Annex 1 finger placement recommendations ...
Page 69: ...69 MorphoWave Compact 2018_2000035853 v81 8 Annex 2 Bibliography ...
Page 72: ...72 MorphoWave Compact 2018_2000035853 v81 9 Annex 3 Support ...