7
IDEMIA D
OCUMENT
- R
EPRODUCTION AND
D
ISCLOSURE
P
ROHIBITED
MORPHOWAVE
TM
OEM - RELAY WIRING
FOR INITIAL VERSION & REVISION 2
2015_2000009095
Power supply
VCC < 30V
Imax < 2A
Deadbolt / Door strike
Push Button on
other side of the
door
Snubber Diode
1
D
2
Relay_NO
Relay_Com
A B C
Deadbolt / Door strike
Push Button on
other side of the
door
Relay
5
RLY_NO
Yellow / White
6
RLY_COM Grey / White
7
RLY_NC
Orange / White
Power supply
VCC < 30V
Imax < 2A
Inductive load management requires a parallel diode for a better contact lifetime