RECOMMENDATIONS 1/2

Warning

The manufacturer cannot be held responsible in case of non-compliance with the following recommendations or incorrect use of the terminal.

General precautions

Do not attempt to repair the MorphoWave

TM

OEM yourself. The manufacturer cannot be held responsible for any damage/accident that may result from 

attempts to repair components. Any work carried out by non-authorized personnel will void your warranty.

Do not expose the terminal to extreme temperatures, outdoor conditions, temperatures exceeding [10

°

C ; 35

°

C].

Only use the terminal with its original accessories. Attempts to use unapproved accessories with your terminal will void your warranty.

Due to electrostatic discharge, and depending on the environment, synthetic carpeting should be avoided in areas where the MorphoWave

TM

OEM.

Areas containing combustibles

It is highly recommended not to install the terminal in the vicinity of gas stations or any other installation containing flammable or combustible gases or 
materials.

Ethernet connection

It is recommended to use a category 5 shielding cable (120 Ohms) or higher. It is also strongly recommended to insert a repeater unit every 90m.

Extreme care must be taken while connecting Ethernet wire to the MorphoWave

TM

OEM terminal block board since low quality connection may strongly 

impact Ethernet signal sensibility.

It is recommended to connect Rx+ and Rx- with the same twisted-pair wire (and to do the same with Tx+/Tx- and the other twisted-pair wire).

Biometric sensor maintenance

Clean the glass every day to optimize performances of the product especially when there is heavy dust deposit on the capture window.

Use a dry cloth to clean the terminal and the sensor. The use of acid liquids, alcohol or abrasive materials is prohibited.

Use a dry air spray to remove the dust out of the sensor glass.

Terminals not connected to network

For terminals used in standalone mode (local database only), it is strongly recommended to backup regularly the database.

Date / Time synchronization

If you want to use the MorphoWave

TM

OEM terminal for application requiring high time precision, we recommend synchronizing regularly your 

MorphoWave

TM

OEM terminal time with an external clock.

The MorphoWave

TM

OEM terminal clock has a +/- 10 ppm typical time deviation at +25

°

C (r/- 1sec per day).

At lower and higher temperature, deviation may be more important.

2015_2000009095

Summary of Contents for MorphoWave OEM

Page 1: ...IDEMIA DOCUMENT REPRODUCTION AND DISCLOSURE PROHIBITED MorphoWaveTM OEM Quick User Guide 2015_2000009095 V3...

Page 2: ...roduct Overview The MorphoWaveTM OEM offers the fingerprint contactless sensor technology for a wide range of application as access control and time attendance With an easy way to administrate the dev...

Page 3: ...aclock or RS485 protocols The MorphoWaveTM OEM terminal sends User ID to the Controller The Controller sends its decision to the MorphoWaveTM OEM terminal which displays access is granted or denied on...

Page 4: ...provided by a 12 Volts Wiegand power supply which complies with the Security Industry Association s Wiegand standard March 1995 Power over Ethernet POE MorphoWaveTM OEM terminal s power supply can als...

Page 5: ...east 48 hours at 25 C Don t forget to change battery after long power cut or after several short power cut C 1 6 2 5 4 3 Power Supply 12V Power Ground Tamper switch 2 Tamper switch 1 Digital Ground Di...

Page 6: ...RS422 485_GND Black Red Wiegand IN Wiegand OUT 22 WIEGAND_IN0 Green Red 23 WIEGAND_IN1 White Red 20 WIEGAND_GND Black Red 24 WIEGAND_OUT0 Green 21 WIEGAND_OUT1 White 25 WIEGAND_LEDOUT1 Blue 26 WIEGAND...

Page 7: ...ire shall be connected together Power supply from electrical source shall be switched off before starting the installation Before any installation please refer to the MorphoWaveTM OEM Installation Gui...

Page 8: ...Imax 2A Deadbolt Door strike Push Button on other side of the door Snubber Diode 1 D 2 Relay_NO Relay_Com A B C Deadbolt Door strike Push Button on other side of the door Relay 5 RLY_NO Yellow White...

Page 9: ...or and position the cable between the metal frame and the bracket Use the tie wrap provided to attach the cable to the bracket through the pre drilled hole Reattach the rear cover To access to the pow...

Page 10: ...on PC side the middle plastic part is blue Connect the power adaptor of the PC to the unit Connect RJ45 cable on the PC for Ethernet connectivity Please use only the power adaptor provided with the P...

Page 11: ...uest the terminal checks user s access rights using a biometric check If the result of the check is successful access granted a message is sent to the Central Access Controller for additional access r...

Page 12: ...st can be triggered by entering user id through keypad or through Wiegand command Terminal compares the data provided by the user with the reference data provided by the same user during enrollment ph...

Page 13: ...selection of several languages i e English French and Spanish are available 3 Trigger Event Activate trigger events such as Biometric Keypad or External Port The access rights check process is initiat...

Page 14: ...rminal user enrollment can be performed In Terminal Database enrollment requires gathering the data listed below User s Name and Last name Capture Fingers for biometric check Terminal auto selects bes...

Page 15: ...PROHIBITED ENROLLMENT PROCESS 2 2 2015_2000009095 1 2 3 NB To complete enrollment two waves are required The operator has to choose the hand to enroll Up to 4 fingers per hand can be selected for enro...

Page 16: ...15 IDEMIA DOCUMENT REPRODUCTION AND DISCLOSURE PROHIBITED MORPHOWAVETM ACQUISITION GUIDELINES 1 2 2015_2000009095 Ideal acquisition procedure...

Page 17: ...16 IDEMIA DOCUMENT REPRODUCTION AND DISCLOSURE PROHIBITED MORPHOWAVETM ACQUISITION GUIDELINES 2 2 2015_2000009095 Improper use...

Page 18: ...ure T A mode It is possible to activate and configure T A mode using a set of parameters from MBTB software In normal mode there are 4 function keys that can be associated with T A action and displaye...

Page 19: ...igured using terminal administration menu System Menu Terminal Settings Video Phone Configuration You can Add a Video Phone Server in Terminal View or Delete a Video Phone server Note Terminal can be...

Page 20: ...TM OEM terminal is to use MorphoBioToolBox application The application will connect to MorphoWaveTM OEM through Ethernet by entering IP address This application has to be installed on administration P...

Page 21: ...y 5 shielding cable 120 Ohms or higher It is also strongly recommended to insert a repeater unit every 90m Extreme care must be taken while connecting Ethernet wire to the MorphoWaveTM OEM terminal bl...

Page 22: ...2015_0000010424 These documents describe the different functions available on the terminal and procedures for configuring the terminal It also contains the full description of all the configuration pa...

Page 23: ...IDEMIA Support Terminaux Biom triques 18 Chauss e Jules C sar 95520 Osny FRANCE support bioterminals idemia com Phone 33 1 30 20 30 40 9H00am to 5H30pm French Time Monday to Friday http www biometric...

Reviews: