RECOMMENDATIONS 1/2
Warning
•
The manufacturer cannot be held responsible in case of non-compliance with the following recommendations or incorrect use of the terminal.
General precautions
•
Do not attempt to repair the MorphoWave
TM
OEM yourself. The manufacturer cannot be held responsible for any damage/accident that may result from
attempts to repair components. Any work carried out by non-authorized personnel will void your warranty.
•
Do not expose the terminal to extreme temperatures, outdoor conditions, temperatures exceeding [10
°
C ; 35
°
C].
•
Only use the terminal with its original accessories. Attempts to use unapproved accessories with your terminal will void your warranty.
•
Due to electrostatic discharge, and depending on the environment, synthetic carpeting should be avoided in areas where the MorphoWave
TM
OEM.
Areas containing combustibles
•
It is highly recommended not to install the terminal in the vicinity of gas stations or any other installation containing flammable or combustible gases or
materials.
Ethernet connection
•
It is recommended to use a category 5 shielding cable (120 Ohms) or higher. It is also strongly recommended to insert a repeater unit every 90m.
•
Extreme care must be taken while connecting Ethernet wire to the MorphoWave
TM
OEM terminal block board since low quality connection may strongly
impact Ethernet signal sensibility.
•
It is recommended to connect Rx+ and Rx- with the same twisted-pair wire (and to do the same with Tx+/Tx- and the other twisted-pair wire).
Biometric sensor maintenance
•
Clean the glass every day to optimize performances of the product especially when there is heavy dust deposit on the capture window.
•
Use a dry cloth to clean the terminal and the sensor. The use of acid liquids, alcohol or abrasive materials is prohibited.
•
Use a dry air spray to remove the dust out of the sensor glass.
Terminals not connected to network
•
For terminals used in standalone mode (local database only), it is strongly recommended to backup regularly the database.
Date / Time synchronization
•
If you want to use the MorphoWave
TM
OEM terminal for application requiring high time precision, we recommend synchronizing regularly your
MorphoWave
TM
OEM terminal time with an external clock.
•
The MorphoWave
TM
OEM terminal clock has a +/- 10 ppm typical time deviation at +25
°
C (r/- 1sec per day).
•
At lower and higher temperature, deviation may be more important.