13
MorphoWave Compact - 2018_2000035853
1.4 > Wiring Recommendations
Idemia recommends using a AWG16 gauge and 24V power supply when PoE+ supply is not used.
The
voltage
specified
is
the
one
measured
on
the
product
block
connector:
12V-24V (-15% / +10%).
The voltage drop due to the cable shall be taken into account. The following table shows the maximum
distance between power supply and one (1) unique device, depending on cable gauge and power supply
rating:
Gauge
AWG
Section
(mm
2
)
Maximum distance (meters) vs power
source rating
12V+/-10%
12V+/-5%
24V+/-10%
16
1.31
9 m
20 m
300 m
18
0.82
6 m
12 m
200 m
20
0.52
3 m
8 m
120 m
22
0.32
2 m
5 m
75 m
Drop voltage = loss of power due to wire resistance and its length: V2 = V1
– Drop voltage
V1
V2
L
Summary of Contents for MorphoWave Compact
Page 1: ...Copyright 2018 Idemia May 2018 2018_2000035853 MorphoWave Compact Installation guide ...
Page 2: ...Copyright 2018 Idemia May 2018 2018_2000035853 ...
Page 9: ...9 MorphoWave Compact 2018_2000035853 1 Introduction ...
Page 21: ...21 MorphoWave Compact 2018_2000035853 2 General description ...
Page 29: ...29 MorphoWave Compact 2018_2000035853 3 Installation procedure ...
Page 37: ...37 MorphoWave Compact 2018_2000035853 3 3 4 Attach the device on the base plate ...
Page 41: ...41 MorphoWave Compact 2018_2000035853 4 Electrical interface ...
Page 58: ...58 MorphoWave Compact 2018_2000035853 5 User interface ...
Page 64: ...64 MorphoWave Compact 2018_2000035853 6 Accessories Software Licenses and PC Applications ...
Page 67: ...67 MorphoWave Compact 2018_2000035853 7 Recommendations ...
Page 70: ...70 MorphoWave Compact 2018_2000035853 8 Annex 1 finger placement recommendations ...
Page 74: ...74 MorphoWave Compact 2018_2000035853 ...
Page 75: ...75 MorphoWave Compact 2018_2000035853 9 Annex 2 Bibliography ...
Page 78: ...78 MorphoWave Compact 2018_2000035853 10 Annex 3 Support ...
Page 80: ...Copyright 2017 Photo GettyImages 656164914 Copyright 2017 Photo GettyImages 656164914 ...