IDEMIA DOCUMENT
– REPRODUCTION AND DISCLOSURE PROHIBITED
Ethernet and Wireless LAN
MorphoAccess® SIGMA Lite Series
– Quick User Guide - 2015_2000005700-V11
12
Step
three
:
c
om
m
unic
at
ion
s
RJ-45
LAN Ethernet
Management
station
Wireless
25
ETH TX+
Orange
1
27
ETH TX-
Orange / White
2
29
ETH RX+
Green
3
31
ETH RX-
Green / White
6
30
ETH VPORT+
Blue
4 & 5
32
ETH VPORT-
Blue / White
7 & 8
28
ETH GND
Drain wire (no color)
Shell
Use a category 5 shielding cable (120 Ohms) or better.
It is strongly recommended to insert a repeater unit every 90m.
By default, MorphoAccess® SIGMA Lite Series terminal is
configured in Static mode.
Terminal Block Ethernet connection
Extreme care must be taken while connecting Ethernet wire to
the block board since low quality connection may strongly
impact Ethernet signal sensibility.
Connect Rx+ and Rx- with the same twisted-pair wire (and to
do the same with Tx+/Tx- and the other twisted-pair wire).
WLAN option
IDEMIA wireless enabled devices support
802.11b and 802.11g standards. WEP Open,
WPA and WPA2 are supported.
IP address
Mode
Parameter
Factory value
Static
Terminal IP
address
192.168.1.10
Gateway IP
address
192.168.1.254
Sub network
mask
255.255.254.0
Host name
MAsigma-lite
MAsigma-lite-plus