background image

Non-Contact RFID Locking Safety Switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Status 

Guard 

Green LED 

Yellow LED 

Locked 

Closed 

Steady 

Off 

Solenoid Power OFF (unlocked) 

Closed 

Flashing 

Off 

Guard Open 

Open 

Off 

Steady 

Door Forced Open 

Open 

Off 

Flashing 

Quick Connect (QC) 

250mm  (10”) 

M12  8-Way 

Male Plug 

 

Conductor 

Colours 

 
 

Function 

 

Power 

Ratings 

Blue 

Supply   0Vdc 

 

50mA max. 

Red 

Supply 24Vdc 

Orange 

Lock Applied (24Vdc) 

500mA max. 

Black 

Safety Output 1 

 

200mA (max. switching) 

White 

Safety Output 1 

Yellow 

Safety Output 2 

 

200mA (max. switching) 

Green 

Safety Output 2 

Brown 

Auxiliary Signal 

+24Vdc 

MGL-1 Switch Dimensions (mm) (Heavy Duty) 

 

Connection Colours                                                                                     

 

IDEM SAFETY SWITCHES Ltd., 2 Ormside Close, Hindley Industrial Estate, Hindley Green, Wigan, WN2 4HR   UK.    Tel: +44 (0)1942 257070    Fax.: +44 (0)1942  257076 

IDEM (USA), 4416 Technology Drive, Fremont, CA 94538   Tel:510-445-0751  Fax:1866-431-7064  email:  

[email protected]

  Web: 

www.idemsafety.com

 

 

       Doc: 102557 
       Aug 17 

                                                     

Standards:

   

ISO14119   EN60947-5-3   EN60204-1 

 

 

ISO13849-1   UL508 

 

 

Dielectric Withstand: 

250V.ac 

 

Insulation Resistance: 

100 Mohms 

 

Switching Distance: 

Sao   1mm   Close 

 

 

Sar    10mm   Open 

 

Tolerance to Misalignment: 

5mm in any direction from a gap of 5mm 

 

Switching frequency: 

1.0 Hz maximum

)

 

 

Approach speed: 

200mm/m   to   1000mm/s 

 

Body material: 

MGL-*P     = Plastic 

 

 

MGL-*M    = Die-Cast Metal 

 

 

MGL-*SS  = Stainless Steel 316 

 

Temperature Range: 

-25C to +40C 

 

Enclosure Protection: 

IP67/IP69K (Stainless Steel) 

 

Cable Type: 

PVC   8 core   6mm OD 

 

Mounting Bolts: 

2 x M5    Tightening torque 1.0 Nm 

 

Mounting Position: 

Any 

 

Power Supply: 

+24Vdc ± 10% (SELV / PELV) 

      Maximum Switched Current (outputs):       200mA   (Minimum internal resistance 8.5 Ohms) 

 
 

Characteristic Data according to EN ISO13849-1:

 

 

Performance Level 

e  If both channels are used in combination with a 

 

 

    SIL3/PLe control device 

 

Category 

Cat4 

 

 

MTTFd 

1100a 

 

 

Diagnostic Coverage DC 

99% (high) 

 

 

Number of operating days per year: 

d

op

 = 365d 

 

Number of operating hours per day: 

h

op

 = 24h 

 

B10d: 

Not mechanical parts implemented 

 

When the product is used deviant from these assumptions (different load, operating frequency, 
etc.) the values have to be adjusted accordingly. 

MGL-2 Switch Dimensions (mm) (Medium Duty) 
 

Pin View from Switch 

LED Operation and Switch Status Indication: 

 

The MGL switch uses 2 LEDs to indicate all the different possible switch states. 

 

The LEDs are in a clearly visible location at either side of the cable exit point. 

 

Actuator Operating Direction:

 

MGL shown in OPEN position. 
Steady Yellow LED indication.

 

MGL shown in CLOSED position, lock energised. 
Steady Green LED indication.

 

INFORMATION WITH REGARD TO UL508 

Type 1 Enclosures. 
Maximum temperature 40ºC.  Maximum output 24V.dc 200mA.                        
Powered by Class 2 or equivalent. 

WARNING:

 Hot surface – risk of burn if used at ambient temperature of +40C degrees.  

(Affix a warning label to the switch). 

 
Original Instructions. 

 
To request this data sheet in other languages please contact 

[email protected]

 

Um dieses Datenblatt in Deutscher Sprache wenden Sie sich bitte anfordern 

[email protected]

 

Pour obtenir cette fiche en Français, veuillez contacter 

[email protected]

 

Para solicitar esta hoja de datos en Español, por favor contacto con 

[email protected]

 

 

   

WARNING:  DO NOT DEFEAT, TAMPER, OR BYPASS THE SAFETY FUNCTION.   

                                        FAILURE TO DO SO CAN RESULT IN DEATH OR SERIOUS INJURY.  
 
         AVERTISSMENT: NE PAS DESACTIVER, MODIFIER, RETIRER, OU CONTOURNER  
                                       CETI INTERVERROUILLAGE IL PEUT EN RESULTER DES   
                                       BLESSURES GRAVES DU PERSONNEL UTILISATEUR.   
 