SA1E-L Miniature Laser Photoelectric Switches (Built-in Amplifier)

Characteristics (Typical)

1. Through-beam SA1E-LT

Excess Gain (without slit)

Excess Gain (with round slit)

Lateral Displacement (without slit)

Excess Gain

1

10

100

50

40

30

20

10

0

Excess Gain

1

10

100

20

25

15

10

5

0

ø2.0 mm

Slit on receiver

ø1.0 mm

Slit on receiver

ø0.5 mm

Slit on receiver

Lateral Displacement Y (mm)

-30

-20

-10

0

0

5 10 15 20 25 30 35 40 45 50

10

20

30

X

Y

Sensing Distance (m)

Sensing Distance (m)

Sensing Distance (m)

Angle (without slit)

Light Beam Diameter

Receiver Angle 

θ

 (°)

-20

-15

-10

-5

0

0

5

10 15 20 25 30 35 40 45 50

5

10

15

20

θ

X

Light Beam Diameter (mm)

0

10

20

30

40

50

60

70

80

90

100

0

5

10 15

20 25 30 35 40 45 50

B

A

A

B

 

Sensing Distance X (m)

Sensing Distance (mm)

2. Polarized Retroreflective SA1E-LP

Excess Gain

Lateral Displacement

Angle

Excess Gain

1

10

100

20

15

10

5

0

IAC-R5/R8

IAC-R9

Lateral Displacement Y (mm)

-15

-10

-5

0

5

10

15

0

1

2

3

4

5

6

7

8

9 10

X

Y

IAC-R5/R8

IAC-R9

Reflector Angle 

θ

 (°)

-50

-40

-30

-20

-10

0

10

20

30

40

50

0

1

2

3

4

5

6

7

8

9 10

IAC-R9

IAC-R5/R8

X

θ

Sensing Distance (m)

Sensing Distance X (m)

Sensing Distance X (m)

Light Beam Diameter

Light Beam Diameter (mm)

0

10

20

30

40

50

60

70

80

90

100

0

5

10 15

20 25 30 35 40 45 50

B

A

A

B

Sensing Distance (mm)

Operation 
Level

Operation 
Level

Operation 
Level

(Light beam diameter)
 

Reference value (visual inspection)

(Light beam diameter)
 

Reference value (visual inspection)

Summary of Contents for SA1E-L Series

Page 1: ...SA1E L Miniature Photoelectric Switches Built in Amplifier Laser Visible red laser beam and fast response speed High precision sensing Through beam Background Suppression BGS Polarized Retroreflective ...

Page 2: ... sensing range or detection of small objects IDEC s Unique Optical Lens Mechanism Parallel beam to the housing axis makes installation of the photoelectric switch easy Housing Beam is parallel to the housing axis Optical Lens positioned to make the beam parallel to the housing axis Optical Lens fixed in the housing Laser Diode fixed in the housing Top View Easy Installation m max Narrow space for ...

Page 3: ...nts exposed to dust or water vapor Dust and water resistant Because the visible red laser is easy to see in both short 20 mm and long 30 m distances the detecting position and optical axis can be found quickly The small beam can detect small objects and it also enables easy positioning of the sensor in applications where the beam has to pass through narrow spaces All models are Class 1 laser compl...

Page 4: ...gth Part No NPN Output PNP Output Through beam 30m Cable 1 m SA1E LTN3 SA1E LTP3 2 m SA1E LTN3 2M SA1E LTP3 2M 5 m SA1E LTN3 5M SA1E LTP3 5M Connector SA1E LTN3C SA1E LTP3C See the characteristics on page 11 Polarized Retroreflective Note See the characteristics on page 11 Cable 1 m SA1E LPN3 SA1E LPP3 2 m SA1E LPN3 2M SA1E LPP3 2M 5 m SA1E LPN3 5M SA1E LPP3 5M Connector SA1E LPN3C SA1E LPP3C Back...

Page 5: ... Brackets Item Part No Package Quantity Reflector Mounting Bracket For IAC R5 IAC L2 Note 1 1 For IAC R9 IAC L3 Note 2 For IAC R8 IAC L5 Note 3 See page 10 for dimensions Note 1 The IAC L2 is not supplied with M4 mounting screws and nuts Note 2 The IAC L3 is supplied with two M3 mounting screws M3 8 mm sems screws Note 3 The IAC L5 is supplied with two M4 mounting screws M4 10 mm sems screws Air B...

Page 6: ...e 10 to 55 C no freezing Operating Humidity 35 to 85 RH no condensation Storage Temperature 25 to 70 C no freezing Storage Humidity 35 to 85 RH no condensation Insulation Resistance Between live part and mounting bracket 20 MΩ minimum 500V DC megger Dielectric Strength Cable models 1 000V AC 50 60 Hz 1 minute between live part and mounting bracket Connector models when connected with connector cab...

Page 7: ...ø 3 5 19 5 Note 3 25 4 1 2 3 4 2 M3 Projector 3 2 Through beam Through beam Polarized Retroreflective Background Suppression BGS Polarized Retroreflective Background Suppression BGS Connector Model Note 1 No stable LED sensitivity control and operation mode switch are attached on the through beam projector Note 2 Power ON LED green for through beam projector Note 3 Cable length depends on models N...

Page 8: ...3 2 3 2 25 19 14 4 46 18 13 2 5 7 6 ø55 ø39 19 29 7 20 40 5 5 5 5 1 2 19 5 29 0 0 6 15 0 5 3 31 5 ø39 0 ø55 0 9 3 7 2 3 2 17 1 25 4 8 0 12 3 10 8 13 0 18 0 55 0 Note 1 Note 3 Note 2 SA9Z K03 Note 1 Projector through beam Receiver through beam Note 2 Projector polarized retroreflective background suppression Note 3 Receiver polarized retroreflective With Mounting Bracket 1 2 14 6 34 8 55 0 10 6 ø3 ...

Page 9: ...erial Stainless Steel All dimensions in mm SA9Z K04 Reflector 61 8 Reflecting surface 47 47 2 ø4 5 30 40 30 4 51 2 51 2 IAC R8 IAC R5 Reflecting surface 47 2 47 2 2 ø4 3 51 72 60 3 9 Reflecting surface 47 47 6 6 1 3 5 4 4 61 6 51 5 51 6 40 20 2 R 2 2 2 R 2 2 IAC R9 28 4 24 8 10 8 13 4 19 5 1 6 With Mounting Bracket ...

Page 10: ...e installed to either the top or side Tighten the fitting to a torque of 0 5 N m maxi mum The air tube fitting and mounting bracket are not supplied and must be ordered separately recommended mounting bracket SA9Z K01 All dimensions in mm 5 8 14 0 8 0 37 0 25 4 25 0 6 9 M5P0 8 M5P0 8 Material Anodized aluminum surface 2 ø 3 2 3 2 3 5 19 5 2 0 3 8 31 5 Recommended mounting bracket SA9Z K01 Air Blow...

Page 11: ...0 θ X Light Beam Diameter mm 0 10 20 30 40 50 60 70 80 90 100 0 5 10 15 20 25 30 35 40 45 50 B A A B Sensing Distance X m Sensing Distance mm 2 Polarized Retroreflective SA1E LP Excess Gain Lateral Displacement Angle Excess Gain 1 10 100 20 15 10 5 0 IAC R5 R8 IAC R9 Lateral Displacement Y mm 15 10 5 0 5 10 15 0 1 2 3 4 5 6 7 8 9 10 X Y IAC R5 R8 IAC R9 Reflector Angle θ 50 40 30 20 10 0 10 20 30 ...

Page 12: ...nce X mm Sensing Distance mm Light beam diameter Defined as 1 e2 13 5 of the center intensity Color Matte Paper and Other Materials Preset 150 mm Color Matte Paper and Other Materials Preset 300 mm Control Knob vs Sensing Distance Sensing Distance mm 50 0 100 150 200 White Green Red Blue Gray Black Cardboard Aluminum Stainless Steel Black Rubber Brass Sensing Distance mm 0 50 100 150 200 250 300 3...

Page 13: ...he table below adjust the sensitivity of the SA1E L photoelectric switch when necessary in such cases as the through beam is used to detect small or translucent objects The table explains the status of operation LED when the operation mode is set to light ON Step Photoelectric Switch Status Sensitivity Control Adjusting Procedure 1 Receiving light Through beam polarized retroreflective No object d...

Page 14: ...tion and damage may be caused Inductive devices or heat source Extreme vibration or shock Large amount of dust Toxic gases Water oil chemicals Outdoors Make sure to prevent sunlight fluorescent light and especially the fluorescent light of inverters from entering the receiver of the pho toelectric switch directly Keep the through beam type receiver away from intense extraneous light Interference p...

Page 15: ...ize sensing errors If the SA1E L is used in a place subject to large variations in the ambient temperature the characteristics may change depending on the target object Be sure to check the operation under the actual operating conditions Polarized retroreflective when the sensing objects have mirror surface the reflected light from the mirror surface might cause false detection Make sure that the ...

Page 16: ...cting transparent objects Photo Polarized retroreflective Cable Model All dimensions in mm 10 8 31 5 19 5 Photo Through beam Connector Model 10 8 31 5 10 8 19 5 1 2 3 4 5 1 T Through beam Infrared LED TA Through beam Red LED P Polarized Retroreflective Red LED D Diffuse reflective Infrared LED N Small beam Reflective Red LED B Background Suppression BGS Red LED G Convergent Reflective Infrared LED...

Reviews: