background image

( 9 / 9 )

B-2048-1(1)

INSTRUCTION SHEET - HS1T Series 

Solenoid Type Safety Switch

2019.07

9

Precaution for Disposal

Dispose of the HS1T safety switch as an industrial waste.

http://www.idec.com

Manufacturer: IDEC CORP. 

2-6-64 Nishimiyahara Yodogawa-ku, Osaka 532-0004, Japan

EU Authorized Representative:APEM SAS

55, Avenue Edouard Herriot BP1, 82303 Caussade Cedex, France

DECLARATION OF CONFORMITY

We, IDEC CORPORATION 2-6-64, Nishimiyahara Yodogawa-ku,Osaka 532-0004, Japan declare 

under our sole responsibility that the product:

Description: Safety Switch

Model No: HS1T

to which this declaration relates is in conformity with the EU Directive on the following standard(s) 

or other normative document(s). In case of alteration of the product, not agreed upon by us, this 

declaration will lose its validity.
Applicable EU Directive :  Low Voltage Directive (2014/35/EU)

 

  Machinery Directive (2006/42/EC)

                                          RoHS Directive (2011/65/EU)
Applicable Standard(s)  : EN 60947-5-1,GS-ET-19,EN 50581

20.5

11.5

22

40

40

(

42.5

)

12.3

0.8

43

18.6

3

5.1

φ

5.1

φ

15

90

°

22

40

22

43

18.6

47

9

19.3

0.8

φ

5.1

φ

15

When installed on

3

5.1

Actuator Stop

(Supplied with actuator)

When installed on

 Actuator dimensions

Type : HS9Z-A11T

(To be sold by separately)

Type : HS9Z-A12T

HS9Z-A11T/A12T Actuator mounting hole layout

2-M5

(

Φ5.2 or M5 tapped)

Type

 : HS1T-

4LSM

 For straight actuators

For L-type actuators

Rear Unlock Button

(

取付基準

)

Slot Plug

(

取付基準

)

52.3

(

19.1

±

0.5

)

11

5

(

16.6

±

0.5

)

22.5

104.6

7

1

4.6

4

(

5.1

±

0.5

)

(

2.6

±

0.5

)

4

7.1

30

22

40

170

125.5

40.1

56.2

59.4

9

20.8

30

φ

5.2

40

20

7

45

17.5

104.6

61.6

2.5

35

56

8

(

8

)

54.9

7

8

30

125.5

φ

20

20.8

Main body mounting hole layout

3-M5 Safety Switch 

Mounting Holes

φ

5.1

HS9Z-A12T

Actuator

HS9Z-A11T

Actuator

Rear Unlock Indicator

Rear Unlock Button

Rear Unlock Button

(RP)

(RP)

Summary of Contents for HS1T Series

Page 1: ...cle 10 mA LED Green Type 2 Interlocking device low level coded actuator EN ISO ISO14119 EN ISO ISO14119 IEC60947 5 1 EN60947 5 1 GS ET 19 UL508 CSA C22 2 No 14 GB T 14048 5 IEC60204 1 EN60204 1 Low Voltage Directive Machinery Directive 2 5A AC Resistive load AC12 Inductive load AC15 DC Resistive load DC12 Inductive load DC13 30V 125V 250V 2 5A 1 5A 1 5A 0 75A 2 0A 0 4A 0 2A 1 0A 0 22A 0 1A Class I...

Page 2: ...ctual applica ion before installation Actuator Mounting Reference Position As shown below the mounting reference position of the actuator inserted into the safety switch is After mounting the actuator remove the actuator stop from the safety switch When using the safety switch for a hinged door the minimum radius of the applicable door is shown in the following figures Minimum Radius of Hinged Doo...

Page 3: ... cycling testing of the device to the control system to prevent product failure Regardless of door types do not use the safety switch as a door stop Install a mechanical door stop to the end of the door to protect the safety switch against excessive force Mount the actuator so that it will not hit the operator when the door is open other wise injury may be caused Pay attention to the management of...

Page 4: ... safety hedge Use the rear unlock indicator by attaching it to the display area on either side of the safety switch The Rear Unlock Button Lock Release Rear Unlock Status Normal Status Contact Configuration and Operation Contact Congifiguration 11 9 HS1T TJ HS1T TG HS1T TF HS1T TD HS1T TC HS1T TB HS1T TA HS1T J HS1T G HS1T F HS1T D HS1T C HS1T B HS1T A HS1T XB HS1T DD HS1T VG HS1T VH HS1T VF HS1T ...

Page 5: ...ng for guard locking devices Section 5 7 2 2 When a lock monitor circuit contact has the locking monitoring marking it means that one circuit contact can monitor the position and the locking function of the protective door The locking monitoring circuit contact turns ON only when the protective door is closed and locked note Both types of HS1T safety switches spring lock type switches and solenoid...

Page 6: ...of gasket is completely tightening the cable The waterproof gasket is not properly tightening the cable Spring Force Terminal Spring Force Terminal Safety Switch A Gasket Sheath B Terminal Cover CAUTION Make sure not to lose any screw when removing the terminal cover from the switch Please make sure the cable is insterted deep enough into the terminal cover so that the waterproof gasket can tighte...

Page 7: ...d by IDEC CORPORATION HS9Z A11T Actuator HS1T VB4 Safety Switch with Solenoid Used as open close monitor of guard Guard Open Output Circuit HR1S AF Safety relay module One of the example of the circuit Safety relay module HR1S AF series manufactured by IDEC CORPORATION HS9Z A11T Actuator HS1T VB4 Safety Switch with Solenoid Used as open close monitor of guard Guard Open Example of a circuit diagra...

Page 8: ...ator Rear Unlock Button Rear Unlock Button RP RP 7 8 30 125 5 Main body moun ing hole layout HS9Z A12T Actuator HS9Z A11T Actuator Slot Plug 取付基準 Actuator center position 30 40 143 97 8 40 1 56 2 59 4 9 20 8 30 40 20 6 5 61 6 2 5 17 8 35 56 8 4 7 1 22 54 9 52 3 19 1 0 5 11 5 16 6 0 5 7 1 5 1 0 5 2 6 0 5 8 4 6 4 φ 5 2 φ 5 1 φ 5 1 7 8 30 97 8 HS9Z A11T Actuator HS9Z A12T Actuator HS9Z A11T Actuator ...

Page 9: ... its validity Applicable EU Directive Low Voltage Directive 2014 35 EU Machinery Directive 2006 42 EC RoHS Directive 2011 65 EU Applicable Standard s EN 60947 5 1 GS ET 19 EN 50581 20 5 11 5 22 40 40 42 5 12 3 0 8 43 18 6 3 5 1 φ 5 1 φ 15 90 22 40 22 43 18 6 47 9 19 3 0 8 φ 5 1 φ 15 When installed on 3 5 1 Actuator Stop Supplied with actuator When installed on Actuator dimensions Type HS9Z A11T To...

Reviews: