background image

B-1908-1(0)

INSTRUCTION SHEET - HS1L Series 

Solenoid Type Safety Switch, Inside Connector type

( 4 / 6 )

2016.08

Contact Configuration and Operating Characteristic

5

Contact Operation

Operating Characteristic (reference)

11-42

61-62

31-32

21-52

11-42

21-52

33-34

63-64

Approx.

30.0

61

62

31

32

21

22

63

64

34

33

Approx.

10.0

22

21

41

42

12

11

11

12

42

41

(-)

(+)

A2

A1

Door monitor Lock monitor

HS1L-DQ

HS1L-DT

Monitor Circuit :

Monitor Circuit :

Main Circuit :

Main Circuit :

Main Circuit :

Main Circuit :

Monitor Circuit :

Monitor Circuit :

Contact Configuration *10

Approx.

7 0

Approx.4 2 (Lock)

(Travel : mm)

Type

0 (Actuator Mounting Reference Position)

52

51

51

52

(+)

X2

(-)

X1

Indicator

*9

• Contact operation is based on the condition that the actuator is inserted onto the 

center of the safety switch slot.

• Contact opera ion shows  he HS9Z-A1S, A2S, A3S actuator.
• Use main circuit or monitor circuit with      for the input to safety circuit.

CAUTION

*9  This locking monitoring marking has been newly described in section 9.2.1 of 

EN ISO

 

/ ISO14119.

 

It indicates that any devices with this marking meet the 

following EN ISO

 

/ ISO 14119 requirements:

-  General (- General requirements for guard locking devices) (Section 5.7.1) *
-  Locking monitoring (- Locking monitoring for guard locking devices) (Section 

5.7.2.2)

 

When a lock monitor circuit (contact) has the locking monitoring marking, it 

means that one circuit (contact) can monitor the position and the locking 

function of the protective door.

 

 (The locking monitoring circuit (contact) turns 

ON only when the protec ive door is closed and locked.)

 *note 

Both types of HS1L safety switches - spring lock type switches and solenoid 

lock type switches - have obtained the locking monitoring certification marking. 

Based on risk assessment results, solenoid lock type switches can be used 

only for limited applications which do not especially need to be locked for 

safety.

*10 The Actuator is inserted, and HS1L is locked.

Door States

Manual Unlock Key

Main Circuit 

   11-42

  21-52

Monitor Circuit     31-32

Monitor Circuit     33-34

Monitor Circuit     61-62

Monitor Circuit     63-64

Spring Lock Type (HS1L-

4)

Solenoid Power   A1-A2
Solenoid Lock Type (HS1L-

7Y)

Solenoid Power   A1-A2 

Closed

-

Closed
Closed

Open

Closed

Open

Off

On

Closed

-

Open

Closed

Open

Open

Closed

On

Off

Open

-

Open
Open

Closed

Open

Closed

Off / On

Off / On

*12

Closed

Turn the key 

to unlock position

Open

Closed

Open

Open

Closed

Off

Off

*11 *12

Operation Cycle

Door is locked.

The machine can 

be operated.

•Door is unlocked.

•The machine can

  not be operated.

•The machine can

  not be operated.

•Door is unlocked.

•The machine can

  not be operated.

CAUTION

*11  Do not attempt manual unlocking when the solenoid is energized.
*12  Do not energize the solenoid for a long time while the door is open or when the 

door is unlocked manually.

6

Wiring

* Do not remove the wires of the 

terminals 12-41 and 22-51, because 

these terminals are interconnected in 

factory for safety circuit inputs. Use 

terminals 11-42 or 21-52 for safety 

circuit inputs. 

I

50±2

60±2

II

Wire Length : L (mm)

Through Conduit Port

Wire Length inside the Safety Switch

I

II

C

D

E view

B

A

Cable side applicable connector

L

Safety Switch

Conduit hole

 connector

When wiring, the terminal number on each contact is 

identified by connector number.

The following shows the identification of terminal 

number.

Terminal Number Identification

X2

X1

A2

A1

B2

B1

A2

A1

62

64

32

34

52

42

11

61

63

31

33

21

B3

B2

B1

A4

A3

A2

A1

B4

A  The connector built in 

  the safety switch E view

B  The connector built in 

  the safety switch E view

    A   The connector built in the safety switch
   

Tab housing : 1-1903130-4 (8pin) (made by Tyco Electronics AMP K.K.)

    B   The connector built in the safety switch
   

Tab housing : 1-1903130-2 (4pin) (made by Tyco Electronics AMP K.K.)

    C   Cable side applicable connector (option)
   

D-1200D series (made by Tyco Electronics AMP K.K.)

   

Receptacle housing : 1-1827864-4 (8pin)

    D   Cable side applicable connector (option)
   

D-1200D series (made by Tyco Electronics AMP K.K.)

   

Receptacle housing : 1-1827864-2 (4pin)

   

Receptacle contact :1827586-2 (Applicable cable size : AWG30 to 28, loose piece)

   

 

1827587-2 / 1827588-2 (Applicable cable size : AWG28 to 

   

 

22, loose piece)

  

 

1827589-2 (Applicable cable size : AWG22 to 18, loose piece)

* To prepare correct Cable side appricable connector for the connector type, read the 

instruction sheet and catalog of Tyco Electronics AMP K.K. and understand the 

installation and wiring method.

 : 0.05 to 0.86mm

2

 (AWG30 to 18)

* Confirm application of Receptacle Contact to use.
* When using a stranded wire, make sure that adjoining terminals are not 

short-circuited with protruding core wires. Also, do not solder the core wires to avoid 

protruding wires.

Applicable Wire Size in Cable Side Applicable Connector

Internal Connectors

Conduit Hole Connectors

Use a connector with a degree of protection IP67.
Applicable connector dimensions: See the figure on 

the right.

9mm max.

Conduit Thread

30mm max.

• When using flexible conduit and metal connector
   Applicable Flexible Conduit Example:
   

  Type VF-03 (made by Nihon Flex)

   Applicable Metal Connector Example:
  (G1/2)    Type RLC-103 (made by Nihon Flex)
  (PG13.5)   Type RBC-103PG13.5 (made by Nihon Flex)
   (M20)    Type RLC-103EC20 (made by Nihon Flex)

• When using plastic connector, metal connector and multi-core cable
  (G1/2)  Applicable Plastic Connector Example : 
   

  Type SCS-10

□ 

(made by Seiwa Electric)

   

Applicable Metal Connector Example  : 

   

  Type ALS-16

□□ 

(made by Nihon Frex)

  (PG13.5) Applicable Plastic Connector Example : 
   

  Type ST13.5 (made by LAPP)

    

Applicable Metal Connector Example   : 

   

  Type ABS-

□□

PG13.5 (made by Nihon Flex)

  (M20) 

Applicable Plastic Connector Example : 

   

  Type ST-M20×1.5 (made by LAPP)

   

Applicable Metal Connector Example   : 

   

  Type ALS-

□□

EC20 (made by Nihon Flex)

Note :  Confirm the outside diameter of the multi-core cable, the connector type 

depends on the outside diameter of multi-core cable.

Note :  When using ST-M20×1.5, use with gasket GP-M (Type No: GPM20, made by 

LAPP).

(Actuator 

 Pulled Out)

(Actuator 

 Completely Inserted)

Contact Closed

Contact Open

Summary of Contents for HS1L Series

Page 1: ...y 100 000 operations min 900 operations hour Rated Load 900 operations hour 24V AC DC 0 1A Resistive Load 1 000 000 operations min IP67 IEC60529 Degree of Protection 100A 250V Conditional short circuit current Solenoid Indicator Shock Resistance Vibration Resistance Fzh 3 000N minimum F1max 3 900N minimum GS ET 19 2 3 4 Ratings approved by safety agencies 1 TÜV rating AC 15 250V 2 5A DC 13 30V 2 5...

Page 2: ...from the mounting reference position Actuator Mounting Reference Position Actuator Mounting Tolerance HS9Z A1S Actuator Cover Safety Switch Door Stop Door Stop Actuator Cover Safety Switch Safety Switch HS9Z A2S HS9Z A3S Stop film 3 3 2 6mm Deviation of Deviation of actuator position door position 0 5mm 0 5mm Center Center Safety Switch HS9Z A1S and A2S HS9Z A3S 2 6mm 3 3mm HS9Z A1S and A2S HS9Z A...

Page 3: ...ors will cause a break down of the safety switch Solenoid Indicator has polarity Besure to wire correctly Fully press down on the lock nut of the safety switch so they are not lifting or rattling when tightening the connector Tighten it carefully so that there is no gap between the connector and safety switch A L shaped wrench attached to the safety switch Type HS9Z T1 A A To ensure safety make su...

Page 4: ...d in factory for safety circuit inputs Use terminals 11 42 or 21 52 for safety circuit inputs I 50 2 60 2 II Wire Length L mm Through Conduit Port Wire Length inside the Safety Switch I II C D E view B A Cable side applicable connector L Safety Switch Conduit hole connector When wiring the terminal number on each contact is identified by connector number The following shows the identification of t...

Page 5: ... of the circuit Safety relay module HR1S AF series manufactured by IDEC CORPORATION Used as open close monitor of guard Used as lock unlock monitor Output Circuit S1 HS1L DQ4 Safety Switch with Solenoid S2 Starting Switch HW Series Momentary S3 Unlocking Enabling Switch S4 Safety limit Switch ESC Outside start condition K3 4 Safety Contactor F1 Outside fuse of safety relay module at power supply l...

Page 6: ... this declaration relates is in conformity with the EC Directive on the following standard s or other normative document s In case of alteration of the product not agreed upon by us this declaration will lose its validity Applicable EC Directive Low Voltage Directive 2014 35 EU Machinery Directive 2006 42 EC Applicable Standard s EN 60947 5 1 GS ET 19 Type HS9Z A3S HS9Z A1S 33 88 4 104 7 5 2 49 5 ...

Reviews: