Comparison between Adjustable and Non-adjustable Keys
Key Angle Adjustment
• Using the screw (M3 hex socket head screw), the actuator angle can
be adjusted (refer to the dimensional drawing). Adjustable angle:
(0˚) to 20˚
• The larger the adjusted angle of the actuator, the smaller the appli-
cable radius of the door opening.
• After installing the actuator, open the door. Then adjust the actuator
so that its edge can be inserted properly into the entry slot of the
safety switch.
• Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm)
• After adjusting the actuator angle, apply loctite or the like to the
adjustment screw so as to prevent its loosening.
Accessories con’t
Door Hinge
M
in
im
u
m
R
a
d
iu
s
5
0
0
m
m
M
in
im
u
m
R
a
d
ius
6
0
0
m
m
HS9Z-A52
Actuator
Minimum Radius
400mm
Door Hinge
800mm
Minimum Radius
HS9Z-A2
Actuator
Non-adjustable Key HS9Z-A2
Non-adjustable Key HS9Z-A1
HS9Z-A53
Actuator
M
in
im
um
R
ad
iu
s
10
0m
m
Adjustable Key HS9Z-A3
HS9Z-A3
Key
HS9Z-A2
Key
HS9Z-A1