background image

Safety Products

HS1E Series

www.idec.com   

   

USA: (800) 262-IDEC or (408) 747-0550,   Canada: (888) 317-IDEC

B1-31

B1

Safety Products

Ordering Information

Indicator Rated Voltage: 
    4 (24V DC)
    0 (without indicator)

Circuit Diagram No. 
                      Main Circuit         Auxiliary Circuit
       Blank:     1NC+1NC            1NO/1NO
       1:             1NC+1NC            1NO
       2:             1NC+1NC            1NC+1NC
       3:             1NC+1NC             1NC

HS1E  -  2 4 4 K R - R

Indicator Color:
    R (Red)
    G (Green)

Manual Unlock Key:
   K     (with key)
   Blank (without key)

Specifications

Conforming to Standards

EN1088, IEC60947-5-1, EN60947-5-1(TUV), IISO14119,
GS-ET-19 (BG), UL508, CSA C22.2 No. 14 (c-UL)

Applicable Use

IEC60204-1, EN60204-1

Operating Temperature

–20 to +40˚C (no freezing)

Storage Temperature

–40 to +80˚C 

Operating Humidity

40 - 85% (no condensation)

Altitude

2,000m maximum

Rated Insulation Voltage (Ui)

300V (between LED or solenoid and ground: 60V)

Impulse Withstand Voltage (Uimp)

4 kV (between LED or solenoid and ground: 2.5 kV)

Insulation Resistance
(measured with 500V DC megger)

Between live and dead metal parts:   100 M

 minimum

Between live metal part and ground: 100 M

 minimum

Between live metal parts:                   100 M

 minimum

Between terminals of the same pole: 100 M

 minimum

Electric Shock Protection

Class II (according to IEC61140)

Pollution Degree

3 (IEC60947-5-1)

Degree of Protection

IP67 (IEC60529)

Vibration 
Resistance

Operating Extremes

10 to 55 Hz, minimum (amplitude 0.35 mm)

Damage Limits

50 m/sec

(approx. 5G) 

Shock Resistance

1,000 m/sec

(approx. 100G)

Actuator Tensile Strength when Locked

1,500N minimum (per GS-ET-19)

Actuator Operating Speed

1 m/sec maximum

Positive Opening Travel

11 mm minimum

Positive Opening Force

20N minimum

Thermal Current (Ith)

Main circuit: 10A, Auxiliary circuit: 3A

Rated Operating Current (Ie)

Rated operating voltage (Ue)

30V

125V

250V

Main

Circuit

AC

Resistive load (AC12)
Inductive load (AC15)

10A
10A

10A
5A

6A
3A

DC

Resistive load (DC12)
Inductive load (DC13)

6A
3A


0.9A


Auxiliary

Circuit 

AC

Resistive load (AC12)
Inductive load (AC15)


3A

3A
3A

DC

Resistive load (DC12)
Inductive load (DC13)

3A


0.9A


Contact Gap

Main circuit: 1.7 mm min., Auxiliary circuit: 1.2 mm min.

Operating Frequency

900 operations/hour max.

Mechanical Life

1,000,000 operations min. (at full rated load)
900 ops/hr (AC-12/250V, 6A)

Electrical Life

100,000 operations (rated load)

Conditional Short-Circuit Current

100A (per IEC60947-5-1)

Recommended Short 
Circuit Protection

250V, 10A fuse (Type D01 based on IEC60269-1, 60269-2)

Solenoid Unit

Rated Operating Voltage

24V DC

Rated Current

235 mA

Coil Resistance

102

 (at 20

°

C) 

Pickup Voltage

20.5V maximum (at 20

°

C)

DropOut Voltage

2.4 minimum (at 20

°

C) 

Allowable Voltage

26.4V max (continuous)

Insulation Class

Class B

Indicator

Rated Operating Voltage

24V DC

Rated Current

10 mA

Light Source

LED lamp

Lens Color

Red or Green (12 mm dia. Lens)

Weight

Approx. 500g

Specifications

Summary of Contents for HS1E Series

Page 1: ...ent of power failure or for machine maintenance the door can be unlocked using a special tool Flexible Installation The key can be accessed from two directions Also available is a manual unlock key type HS1E Series Full Size Interlock Switch with Locking Solenoid Direct Opening Action GS ET 15 BG standard in Germany EN1088 EN60947 5 1 IEC60947 5 1 Double Insulation Certificate No 2005010305145656 ...

Page 2: ...Extremes 10 to 55 Hz minimum amplitude 0 35 mm Damage Limits 50 m sec2 approx 5G Shock Resistance 1 000 m sec2 approx 100G Actuator Tensile Strength when Locked 1 500N minimum per GS ET 19 Actuator Operating Speed 1 m sec maximum Positive Opening Travel 11 mm minimum Positive Opening Force 20N minimum Thermal Current Ith Main circuit 10A Auxiliary circuit 3A Rated Operating Current Ie Rated operat...

Page 3: ...HS1E 40KR Without With G1 2 HS1E 44KR With With G1 2 1 Special key wrench HS9Z T1 for removing the cover and manual unlocking is included with the switch 2 Specify the circuit diagram No in place of 3 Specify the indicator color R or G in place of 4 Order the key separately not included with the switch Circuit Diagram No Main Circuit Auxiliary Circuit Blank 1NC 1NC 1NO 1NO 1 1NC 1NC 1NO 2 1NC 1NC ...

Page 4: ...in Cir 3 4 Closed 3 4 Open 3 4 Open 3 4 Open 3 4 Open Aux Cir 1 2 Open 1 2 Open 1 2 Closed 1 2 Closed 1 2 Open Solenoid 5 6 Power OFF 5 6 Power ON 5 6 Power ON 5 6 Power OFF 5 6 Power OFF Application Examples and Circuit Diagrams Auxillary Circuit Main Circuit Soleoid Power Microswitch is linked to solenoid mechanically Auxillary Circuit Main Circuit Soleoid Power Microswitch is linked to solenoid...

Page 5: ... Closed 3 4 Open 3 4 Open 3 4 Open 3 4 Open Aux Cir 1 2 Closed 1 2 Closed 1 2 Open 1 2 Open 1 2 Closed Solenoid 5 6 Power OFF 5 6 Power ON 5 6 Power ON 5 6 Power OFF 5 6 Power OFF Application Examples and Circuit Diagrams con t Auxillary Circuit Main Circuit Soleoid Power Microswitch is linked to solenoid mechanically Auxillary Circuit Main Circuit Soleoid Power Microswitch is linked to solenoid m...

Page 6: ...29 121 88 4 104 89 26 30 9 43 40 22 68 8 13 8 ø5 4 R2 7 ø5 2 30 9 43 40 22 13 8 54 3 35 39 7 6 5 1 0 35 39 7 8 5 1 0 26 89 45 4 33 45 4 21 89 33 88 104 4 RP Actuator Mounting Reference Position Actuator Cover 23 5 23 5 23 5 Actuator Actuator Cover RP Actuator Cover Actuator RP Mounting Hole Layout 3 M5 Screws 2 10 49 5 129 121 26 ø5 4 R2 7 ø5 2 2 10 49 5 129 121 26 ø5 4 R2 7 ø5 2 35 39 7 35 39 7 2...

Page 7: ...s The minimum radius of the door opening can be as small as 100mm For HS1 HS2 Series HS9Z A3 Accessories 2 7 4 Actuator Cover 22 6 4 4 R 3 2 30 49 3 22 2 M6 Tapped Holes Actuator Mounting Holes weight 22g Key Cover Key Mounting Holes 2 4 R 3 2 22 7 4 11 41 5 30 Actuator Cover After installing the key remove the key cover weight 22g Key Cover Stop Film Angle Adjustment M3 Hexagon Socket Head Screw ...

Page 8: ...n the door Then adjust the actuator so that its edge can be inserted properly into the entry slot of the safety switch Recommended tightening torque 0 8 N m approx 8 0 kgf cm After adjusting the actuator angle apply loctite or the like to the adjustment screw so as to prevent its loosening Accessories con t Door Hinge M i n i m u m R a d i u s 5 0 0 m m M i n i m u m R a d i u s 6 0 0 m m HS9Z A52...

Page 9: ... while connecting a conduit or wiring If the operating atmosphere is contaminated use a protective cover to prevent the entry of foreign objects into the switch through the actuator entry slots Entry of a considerable amount of foreign objects into the switch may affect the mechanism of the switch and cause a breakdown Do not store the switches in a dusty humid or organic gas atmo sphere For Rotat...

Page 10: ...unlocked refer to the diagram on the right 1 This unlocking method is intended for an escape from a machine when a person is locked in For access to the unlocking entry an access hole should be opened on the mounting panel When opening the hole apply proper pro tection against water or other foreign objects 2 Caution After the unlocking operation put the screw back into the unlocking entry for saf...

Page 11: ...ket head cap screws HS1B 5 0 0 5 N m approx 50 5 kgf cm 2 or 4 pcs of M5 hex socket head cap screws HS2B 5 0 0 5 N m approx 50 5 kgf cm 2 pcs of M5 hex socket head cap screws HS5B 4 0 0 4 N m approx 40 4 kgf cm 2 pcs of M4 hex socket head cap screws HS1E 5 0 0 5 N m approx 50 5 kgf cm 4 or 6 pcs of M5 hex socket head cap screws Key HS9Z A1 A2 5 0 0 5 N m approx 50 5 kgf cm 2 pcs of M6 hex socket h...

Reviews: