Enabling Switches
HE1B Series
Part
Numbers
Item
Installation
Part
Number
Side
HE1B-M1
Front
HE1B-M1N
Current Ratings
Rated
Insulation
V
oltage
(Ui)
AC / DC250V
Thermal
Current (lth)
5A
Rated Operating
Voltage
(Ue)
30V
125V
250V
Rated Operating
Current (le)
AC 50/60Hz
Resistive
Load
(AC-12)
Inductive
Load
(AC-15)
Resistive
Load
(DC-12)
Inductive
Load
(DC-13)
–
–
2A
1A
3A
1.5A
0.4A
0.22A
1.5A
0.75A
0.2A
0.1A
DC
Contact
Structure
SPST-NO three position (OFF-ON-OFF)
Minimum applicable load: AC/DC3V
•
5mA (For reference only).
Operating Characteristics
Position 1
Position 2
Position 3
Approx. 15N
Operating Force (Reference Value)
(When pressing the center of operator)
Approx. 3N
Travel (mm)
0
1.4
±
0.3
2.2
±
0.3
2.7
±
0.5
5.0
: ON (Closed)
: OFF (Open)
Pressing ( )
Releasing ( )