background image

 

To

 

disarm

 

the

 

system

:

 

In

 

arm

 

mode

 

enter

 

pass

 

code

 

then

 

press

 

the

 

[ON/OFF],

 

the

 

unit

 

will

 

sound

 

a

 

long

 

BEEP.

 

The

 

unit

 

is

 

now

 

disarmed.

 

 

To

 

use

 

the

 

BY

PASS

 

mode

:

 

When

 

the

 

alarm

 

is

 

armed,

 

if

 

you

 

wish

 

to

 

pass

 

through

 

the

 

DOOR/GATE

 

without

 

disarming

 

the

 

unit,

 

enter

 

pass

 

code

 

and

 

press

 

the

 

[by

pass]

 

button.

 

This

 

will

 

disarm

 

the

 

unit

 

for

 

15

 

seconds

 

allowing

 

you

 

to

 

pass

 

through

 

the

 

gate

 

or

 

door

 

and

 

close

 

it.

 

If

 

the

 

door

 

or

 

gate

 

remains

 

open

 

for

 

15

 

seconds

 

the

 

unit

 

will

 

sound

 

two

 

loud

 

Beeps

 

to

 

remind

 

you

 

that

 

door

 

or

 

gate

 

is

 

not

 

closed.

 

The

 

unit

 

will

 

sound

 

two

 

loud

 

Beeps

 

every

 

15

 

seconds

 

if

 

the

 

door

 

or

 

gate

 

remains

 

open.

 

Once

 

the

 

door

 

or

 

gate

 

has

 

been

 

closed

 

the

 

unit

 

will

 

rearm

 

itself

 

within

 

5

 

seconds.

 

If

 

the

 

door

 

or

 

gate

 

is

 

then

 

re

opened

 

without

 

a

 

pass

 

code

 

the

 

alarm

 

will

 

sound.

 

 

ALARM

 

When

 

unit

 

is

 

armed,

 

if

 

DOOR/WINDOW/GATE

 

is

 

opened

 

the

 

unit

 

will

 

sound

 

alarm,

 

you

 

must

 

enter

 

your

 

pass

 

code

 

and

 

either

 

the

 

[ON/OFF]

 

or

 

[BYPASS]

 

button

 

to

 

stop

 

the

 

alarm.

 

If

 

you

 

press

 

the

 

[ON/OFF]

 

button

 

you

 

must

 

remember

 

to

 

rearm

 

the

 

unit:

 

if

 

you

 

press

 

the

 

[BYPASS]

 

button

 

the

 

unit

 

will

 

rearm

 

itself

 

within

 

5

 

seconds

 

if

 

it

 

detects

 

that

 

the

 

DOOR/WINDOW/GATE

 

is

 

closed.

 

If

 

at

 

any

 

time

 

you

 

enter

 

a

 

wrong

 

pass

 

code

 

the

 

unit

 

will

 

sound

 

two

 

loud

 

DE

 

DE

 

sounds:

 

re

‐ 

enter

 

pass

 

code.

 

 

LOW

 

BATTERY

 

 

When

 

battery

 

is

 

low

 

the

 

unit

 

will

 

flash

 

once

 

per

 

second.

 

Replace

 

battery

 

immediately

 

to

 

maintain

 

protection.

 

 

Summary

 

Notes

:

  

 

When

 

alarm

 

is

 

activated

 

it

 

will

 

ring

 

for

 

10

 

seconds

 

and

 

stop

 

for

 

10

 

seconds.

 

It

 

will

 

then

 

repeat

 

until

 

the

 

alarm

 

is

 

DISARMED,

 

BY

PASS

 

engaged

 

or

 

battery

 

dies.

 

 

The

 

spacing

 

between

 

the

 

2

 

magnetic

 

sensors

 

should

 

be

 

no

 

more

 

then

 

¼”.

 

The

 

alarm

 

will

 

sound

 

at

 

½”

 

spacing

 

and

 

over.

 

 

Keep

 

the

 

unit

 

in

 

the

 

armed

 

state

 

and

 

use

 

the

 

BY

PASS

 

to

 

exit.

 

This

 

reduces

 

the

 

risk

 

of

 

forgetting

 

to

 

arm

 

the

 

unit.

 

 

When

 

the

 

unit

 

is

 

armed,

 

the

 

alarm

 

will

 

sound

 

when

 

the

 

door

 

is

 

opened

 

from

 

the

 

outside.

 

Key

 

in

 

the

 

pass

 

code

 

and

 

BY

PASS

 

to

 

stop.

 

 

When

 

the

 

alarm

 

is

 

armed

 

and

 

TRIGGERED

 

by

 

opening

 

the

 

door,

 

even

 

if

 

the

 

door

 

is

 

closed

 

again

 

the

 

alarm

 

will

 

continue

 

to

 

sound

 

until

 

pass

 

code

 

is

 

entered

 

and

 

disarmed

 

or

 

put

 

into

 

By

Pass

 

mode.

 

 

NOTE

:

 

Please

 

preserve

 

this

 

manual.

 

It

 

contains

 

valuable

 

information

 

for

 

properly

 

setting

 

up

 

and

 

operating

 

the

 

system.

 

Please

 

check

 

for

 

updated

 

instructions

 

at

 

www.idealalert.ca

 

 

Thank

 

you

 

for

 

your

 

purchase:

 

If

 

you

 

have

 

any

 

questions

 

about

 

setup

 

or

 

function

 

of

 

this

 

product;

 

please

 

call

 

us

 

at

 

800

361

2236

 

x230(514

363

1030)

 

before

 

returning

 

to

 

the

 

point

 

of

 

purchase.

 

Perhaps

 

we

 

can

 

resolve

 

your

 

difficulty

 

and

 

eliminate

 

future

 

customer

 

dissatisfaction

Summary of Contents for SK637

Page 1: ...nd muffle the sound OWNER S MANUAL AND SET UP INSTRUCTIONS Thank you for choosing Ideal Security s Gate Pool Access Alert If you have any questions problems or comments regarding the installation or operation of this system please do not hesitate to contact IDEAL s customer service department through our web site at www idealalert ca via email at info idealalert ca or by calling our toll free numb...

Page 2: ...ts whether door gate is open or closed SPECIFICATIONS Internal power supply 9V alkaline battery included Battery Life In standby mode approximately 1 year Operation temperature 100 to 400 C 14 104 F Operation humidity 80 Storage temperature 200 C 600 C 4 140 F INSTALLATION AND OPERATION BATTERY INSTALLATION 1 Remove bracket Fig1 open the battery cover Fig2 install 9V alkaline battery supplied Fig3...

Page 3: ...e now in pass code change mode c Enter old pass code the unit will sound two Beeps if wrong number entered the unit will make a DU sound Enter your new password the unit will sound three Beeps to let you know the change was successful If unit does not beep three times restart from step a d If you forget your password take battery out for a full two minutes and unit will reset to factory default of...

Page 4: ...er a wrong pass code the unit will sound two loud DE DE sounds re enter pass code LOW BATTERY When battery is low the unit will flash once per second Replace battery immediately to maintain protection Summary Notes When alarm is activated it will ring for 10 seconds and stop for 10 seconds It will then repeat until the alarm is DISARMED BY PASS engaged or battery dies The spacing between the 2 mag...

Page 5: ...e porter des protecteurs d oreilles adéquats ou éloigner le haut parleur des oreilles et assourdir le bruit GUIDE DE L UTILISATEUR ET MODE D EMPLOI Merci d avoir acheté le système d alarme pour portillon et accès à la piscine d Ideal Security Pour des questions des problèmes ou des commentaires sur son installation ou son fonctionnement communiquer avec le service à la clientèle d Ideal par le sit...

Page 6: ...e lorsque l alarme retentit Le voyant clignote toutes les trois secondes lorsque le système est armé 3 Détecteurs magnétiques détectent si une porte ou un portillon est ouvert ou fermé DONNÉES TECHNIQUES Alimentation interne Pile alcaline de 9 V comprise Durée utile de la pile Environ un an en mode de veille Température de fonctionnement 10 40 C 14 104 F Humidité de fonctionnement 80 Température d...

Page 7: ...LOI 1 Changer le code 123 établi par défaut à l usine code de trois chiffres seulement a Confirmer que le système est désarmé b Appuyer sur la touche 1 pendant deux secondes Le système émet un bip Relâcher la touche Le mode de changement de code est maintenant actif c Entrer l ancien code Le système émet deux bips Lorsque le mauvais code est entré le système émet un bruit DU Entrer le nouveau code...

Page 8: ... fermé Le système émet deux avertissements forts lorsque le mauvais code est entré Entrer le code à nouveau PILE FAIBLE Lorsque la pile est faible le voyant clignote une fois par seconde Remplacer immédiatement la pile pour ne pas interrompre la protection En résumé Lorsque l alarme est déclenchée elle retentit pendant 10 secondes et s arrête pendant 10 secondes Ce cycle se répète jusqu au désarme...

Reviews: