6
5
True RMS AC Volt
Range
Resolution
Max Display
Accuracy
400mV
0.1mV
400.0
±(2.0% +8)
40Hz to 60Hz
4V
1mV
4.000
±(1.3% +5)
40Hz to 1kHz
40V
10mV
40.00
±(1.3% +5)
400V
100mV
400.0
40Hz to 1kHz
750V
1V
750
AC Conversion Type:
AC conversions are AC-coupled, true
RMS responding, calibrated to the RMS value sine wave input.
Input and Impedance:
10M
Ω
less than 100 PF.
Crest Factor:
+1.5% additional error for C.F. from 1.4 to 3
+3.0% additional error for C.F. from 3 to 4
To Measure True RMS AC Voltage:
1. Plug the black test lead into the COM port and the red test
lead into the °C°F V
Ω
Hz port.
2. Set the rotary switch to the V position.
3. Push the blue button until
AC
is shown on the display.
4. Connect the meter in parallel with the load or circuit.
5. Measure AC Voltage.
Overload Protection
Function
Overload Protection
VAC & VDC
1000V
AAC & ADC
1A/500V
16A/500V
Ohms (
Ω
)
600VAC/600VDC
Diode
600VAC/600VDC
Continuity
600VAC/600VDC
Unit of Measure Multipliers
For your reference, the following symbols are often used to
make measurement easier:
Symbol
Verbal
Multiplier
M
mega
x 1,000,000
k
kilo
x 1,000
m
milli
÷ 1,000
µ
micro
÷ 1,000,000
Auto Power Off (APO)
The APO sign on the LCD panel indicates the meter is working
in the Auto Power Off mode. If the meter idles for more than 30
minutes, the meter automatically turns the power off. When this
happens, the state (non-logic measurement) of the meter is
saved, the meter can be turned back on by pushing any key
switch or changing the rotary switch. The meter will give an
alarm in 15 seconds before the meter automatically turns the
power off. To disable the auto power off function, power up the
meter while pressing either the range, REL or min/max
switch.
True RMS
˜
Circuit Connection: