IDEAL ND 2365-1 Manual Download Page 10

Lifetime Limited Warranty

This meter is warranted to the original purchaser against
defects in material or workmanship for the lifetime of the meter.
During this warranty period, IDEAL INDUSTRIES, INC. will, at
its option, replace or repair the defective unit, subject to 
verification of the defect or malfunction.

This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or 
unreasonable use of the instrument.

Any implied warranties arising out of the sale of an IDEAL
product, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited
to the above.  The manufacturer shall not be liable for loss of
use of the instrument or other incidental or consequential 
damages, expenses, or economic loss, or for any claim or
claims for such damage, expenses or economic loss.

State laws vary, so the above limitations or exclusions may not
apply to you.  This warranty gives you specific legal rights, and
you may also have other rights which vary from state to state.

Maintenance

Battery Installation or Replacement:

The #61-480 is powered by one 9V battery.  
1.  Remove the test leads from the front terminals and turn the 

meter off.

2.  Remove the screw from the battery cover and lift to remove.
3.  Lift battery box and replace batteries.
4.  Make sure the battery box leads do not become pinched 

between the case and battery cover before replacing the 
battery cover and screw.

Fuse Replacement

1.  Remove the test leads from the front terminals and turn the 

meter off.

2.  Remove the screw from the battery cover and lift to remove.
3.  Remove the screws from the bottom case and the inside of 

the battery cover and lift the case bottom until it unsnaps 
from the case top.

4.  Remove the defective fuse by gently prying one end of the 

fuse loose and sliding the fuse out of the fuse holder.

5.  Install a new fuse of the same size and rating.  Make sure it 

is centered in the fuse holder.

6.  Make sure the battery box leads do not become pinched 

between the case and battery cover before replacing the 
bottom case and battery cover.

IDEAL INDUSTRIES, INC.

Sycamore, IL 60178, U.S.A.
800-304-3578 Customer Assistance
www.testersandmeters.com 

ND 2365-1 

Made in Taiwan

Warning

To avoid electrical shock, remove test lead before opening the
cover. Repairs or servicing not covered in this manual should
only be performed by qualified personnel.

19

Summary of Contents for ND 2365-1

Page 1: ...Hz True RMS 1 7 4 2 3 5 6 Symbols in this Manual This symbol indicates where cautionary or other information is found in the manual Fuse Battery Refer to Figure 1 and to the following numbered steps...

Page 2: ...mode also changes the full scale range of the original voltage or cur rent mode WARNING 1 DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE RATINGS Voltage is not to exceed 1000 Volts Resistance Capacitance...

Page 3: ...alarm 15 seconds before the meter automatically turns the power off To disable the auto power off function power up the meter while pressing either the range or Hz switch True RMS AC Volt Range Resolu...

Page 4: ...test lead into the mA or A port 2 Set the rotary switch to the mA or A position 3 Push the blue button until AC is shown on the display 4 Connect the meter in series with the load or circuit 5 Measure...

Page 5: ...load or circuit 5 Measure Frequency or RPM Overload Protection 600V rms Less than 50Hz the sensitivity is 1 5V DC Current Range Resolution Max Accuracy Voltage Display Burden 40mA 10 A 40 00 0 6 2 20...

Page 6: ...the device being tested contains no voltage 5 Press the range button to select the proper range of the meter 6 Measure resistance 11 Frequency with Hz Switch Function Range Sensitivity Accuracy AC Vol...

Page 7: ...00 Meter indicates actual resistance 3k Multiply meter display reading by 1 000 to acquire actual resistance 30k Multiply meter display reading by 1 000 to acquire actual resistance 300k Multiply mete...

Page 8: ...ress the blue button until is shown on the display 5 Connect the test leads to the diode Normally the forward voltage drop of a good silicone diode is shown between 400V and 90V If the diode under tes...

Page 9: ...Conditions Indoor Use Maximum Altitude 2000 Meter Installation Category IEC 1010 1000V Cat II 600V Cat III Pollution Degree 2 17 Continuity Check To Verify Continuity A continuity test ensures that al...

Page 10: ...ent The 61 480 is powered by one 9V battery 1 Remove the test leads from the front terminals and turn the meter off 2 Remove the screw from the battery cover and lift to remove 3 Lift battery box and...