MEChaNICaL 24 hOUR TIMER

sETTINg Up

The outer dial should be set to the current time.  Rotate 

the dial slowly in a clockwise direction, until the correct 

hour is aligned with the arrow printed on the dial.
Note that the outer dial is printed with the 24hr clock   e.g. 

8.00am = 8 on the dial, 8.00pm = 20 on the dial.  

Do not attempt to rotate the dial in an anti-clockwise 

direction.

pROgRaMMINg sWITChINg TIMEs

Set tappets to outer edge for ON periods and set tappets 

to inner edge for OFF periods.
The example shown has been set with 2 on periods.
ON at 9.00am.  OFF at 1.00pm. (13 hours)
ON at 6.00pm. (18 hours)  OFF at 10.00pm (22 hours)

noTE

If boiler does not light when in “timed on” or “manual on” position, increase temperature on room stat.

MaNUaL sWITCh OpERaTION

To set the timer for timed operation move the switch to the “TIMED” position.
To set the timer to be continuously on, move the switch to the “MANUAL ON” position.
To set the timer to be continuously off, move the switch to the “MANUAL OFF” position.

Summary of Contents for MINI C24

Page 1: ...mance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For the very latest copy of literature for specification and maintenance pract...

Page 2: ...ler must be installed by a Gas Safe Registered Engineer in accordance with the above regulations In IE the installation must be carried out by a Registered Gas Installer RGII and installed in accordan...

Page 3: ...tion boiler which is most efficient when operating in condensing mode The boiler will operate in this mode if the CH temperature control C is set to the e position economy mode This control should be...

Page 4: ...ave to be made before it fully defrosts Warm water can also be poured onto the pipe from a watering can or similar DO NOT use boiling water 3 Caution when using warm water as this may freeze and cause...

Page 5: ...on the dial Do not attempt to rotate the dial in an anti clockwise direction PROGRAMMING SWITCHING TIMES Set tappets to outer edge for ON periods and set tappets to inner edge for OFF periods The exam...

Page 6: ...provide central heating Check the time settings on the programmer are as you require and adjust if necessary Check the timer is in an ON position and the room thermostat is turned up NO HOT WATER OR C...

Page 7: ...for central heating but the appliance has reached the desired temperature set on the boiler The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler...

Page 8: ...PTION Low Water Pressure ACTION Check system pressure is between 1 1 5bar on the pressure gauge If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe R...

Reviews: